Effect of cup geometry and the presence of cement on acetabular component fixation

  • Original Articles
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Summary

Two series of implanted conical, polyethylene Ring cups were studied clinically and radiographically. In one series the cups were uncemented while in the second cement was used. The results using cemented conical cups were then compared with results using a cemented cup of hemispherical design to study the effect of cup geometry. At 7–8 years a total of 3.8% of the cemented conical series and 2.9% of the uncemented were revised for aseptic loosening. At 9 years survivorship was identical. Migration of the sockets occurred in approximately 25% of both series and was directly related to cup cover of less than 80% (P < 0.001). The series of cemented hemispherical cups were reviewed after an identical period. Although the numbers revised for loosening were comparable in this and the cemented conical group, radiological migration was statistically greater in the latter (P < 0.001). Alternative methods of socket preparation and cement technique were thought to be the most likely explanation for the observed differences.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Hodgkinson JP, Shelley P, Wroblewski BM (1988) The correlation between X-ray appearance and operative findings at the bone cement junction of the cup in LFA. Clin Orthop 228:105–109

    Google Scholar 

  2. Albrecht-Olsen P, Owen-Falkenberg T, Burgaard P, Bogeskov Andersen P (1989) Nine year follow-up of the cementless Ring hip. Acta Orthop Scand 60:77–80

    Google Scholar 

  3. Engh CA, Griffin WL, Marx CL (1990) Cementless acetabular components. J Bone Joint Surg [Br] 72:53–59

    Google Scholar 

  4. DeLee JG, Charnely J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20–32

    Google Scholar 

  5. Hozack WJ, Rothman RH, Booth RE, Balderstone RA, Cohn JC, Pickens GT (1990) Survivorship analysis of 1,041 Charnley total hip arthroplasties. J Arthroplasty 5:41–47

    Google Scholar 

  6. Massin P, Schmidt L, Engh CA (1989) Evaluation of cementless acetabular component migration. J Arthroplasty 4:245–251

    Google Scholar 

  7. Bertin KC, Freeman MAR, Morscher E, Ring PA (1985) Cementless acetabular replacement using a pegged polythene prosthesis. Arch Orthop Trauma Surg 104:251–261

    Google Scholar 

  8. Charnley J (1979) Low friction arthroplasty of the hip. Springer, Berlin Heidelberg New York, p 88

    Google Scholar 

  9. Linder L, Carlsson AS (1986) The bone cement interface in hip arthroplasty. Acta Orthop Scand 57:495–500

    Google Scholar 

  10. Malcolm AJ (1990) Pathology of cemented low friction arthroplasties in autopsy specimens. In: Older MWJ (ed) Implant bone interface. Springer, Berlin Heidelberg New York

    Google Scholar 

  11. O'Leary JFM, Mallory TH, Kraus TJ, Lombardi AV, Lye C-L (1988) Mittelmeier ceramic total hip arthroplasty. J Arthroplasty 3:87–96

    Google Scholar 

  12. Apel DM, Smith DG, Schwartz CM, Paprosky WG (1989) Threaded cup acetabuloplasty — early clinical experience. Clin Orthop 241:183–189

    Google Scholar 

  13. Ling RSM (1980) Total hip replacement using a collarless femoral prosthesis. Hip 5:82

    Google Scholar 

  14. Dobbs HS (1980) Survivorship of total hip replacements. J Bone Joint Surg [Br] 62:168–173

    Google Scholar 

  15. Sutherland CJ, Wilde AH, Borden LS, Marks KE (1982) A ten year follow-up of 100 consecutive Muller curved-stem total hip arthroplasties. J Bone Joint Surg [Br] 64:970–982

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Timperley, J., Bannister, G., Gie, G. et al. Effect of cup geometry and the presence of cement on acetabular component fixation. Arch Orthop Trauma Surg 111, 301–304 (1992). https://doi.org/10.1007/BF00420054

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00420054

Keywords

Navigation