Normal human skin echogram

  • Original Contributions
  • Published:
Archives of Dermatological Research Aims and scope Submit manuscript

Summary

Sector B-mode echograms of the stratum corneum from the top of pemphigus foliaceus bulla, 15/1,000 inch split-thickness skin graft including the epidermis and superficial dermis, and the whole skin with subcutaneous fat were compared with histologic sections. The corneo-epidermal and epidermo-dermal interfaces were not delineated either by 5, 10 or 15 MHz transducer. The subcutaneous fat exhibited an almost echolucent zone with weak echoes from the fibrous trabeculae or large blood vessels. Regional differences of in vivo normal skin echograms were studied on the forehead, abdomen, back, upper arm, thigh, lower leg and heel. The presence or absence of the cutaneous muscles, fascia or bone was clearly demonstrated. For the standard echogram of the skin, a 10 MHz transducer was considered appropriate, though the detailed echograms were obtained mostly in the deep dermal and subcutaneous structures.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Alexander H, Miller DL (1979) Determining skin thickness with pulsed ultra sound. J Invest Dermatol 72:17–19

    Google Scholar 

  2. Bhagat PK, Kerrick W, Ware RW (1980) Ultrasonic characterization of aging in skin tissue. Ultrasound Med Biol 6:369–375

    Google Scholar 

  3. Chinn DH, Filly RA, Callen PW (1982) Unusual ultrasonographic appearance of a solid schwannoma. J Clin Ultrasound 10:243–245

    Google Scholar 

  4. Cole GW, Handler SJ, Burnett K (1981) The ultrasonic evaluation of skin thickness in scleredema. J Clin Ultrasound 9:501–503

    Google Scholar 

  5. Daly CH, Wheeler JB (1971) The use of ultrasonic thickness measurement in the clinical evaluation of the oral soft tissues. Int Dent J 21:418–429

    Google Scholar 

  6. Goans RE, Cantrell JH, Meyers FB (1977) Ultrasonic pulse-echo determination of thermal injury in deep dermal burns. Med Phys 4:259–263

    Google Scholar 

  7. Goldberg BB (1975) Ultrasonic evaluation of superficial masses. J Clin Ultrasound 3:91–94

    Google Scholar 

  8. Goss SA, Johston RL, Dunn F (1978) Comprehensive compilation of empirical ultrasonic properties of mammalian tissues. J Acoust Soc Am 64:423–457

    Google Scholar 

  9. Kalus AM, Aindow J, Caulfield MR (1979) Application of ultrasound in assessing burn depth. Lancet I:188–189

    Google Scholar 

  10. Medsger TA (1980) Skin thickness index of progressive systemic sclerosis. Skin Allergy News 11:26

    Google Scholar 

  11. Moeller DA, Hirsch J (1982) Ultrasonic evaluation of chronic sporotrichosis. J Clin Ultrasound 10:238–239

    Google Scholar 

  12. Mohar N, Rukavina B, Uremović V (1979a) Ultrasound diagnostics as a method of investigation of plastic induration of the penis. Dermatologica 159:115–124

    Google Scholar 

  13. Payne PA, Grove GL, Alexander H, Quillian RM, Miller DL (1982) Cross-sectional ultrasonic scanning of skin using plastic film transducers. Bioeng Skin 3:241–246

    Google Scholar 

  14. Rukavina B, Mohar N (1979b) An approach of ultrasound diagnostic techniques of the skin and subcutaneous tissue. Dermatologica 158:81–92

    Google Scholar 

  15. Tan CY, Marks R, Roberts E, Guibarra E (1981a) Xeroradiographic and ultrasound techniques in the assessment of skin disorder. In: Marks R, Payne PA (eds) Bioengineering and the skin. MTP Press, Lancaster, pp 215–225

    Google Scholar 

  16. Tan CY, Marks R, Payne P (1981b) Comparison of xeroradiographic and ultrasound detection of corticosteroid induced dermal thinning. J Invest Dermatol 76:126–128

    Google Scholar 

  17. Tan CY, Statham B, Marks R, Payne PA (1982) Skin thickness measurement by pulsed ultrasound: Its reproducibility, validation and variability. Br J Dermatol 106:657–667

    Google Scholar 

  18. Weinraub Z, Brenner S, Krakowski A, Capsi E (1982) The water cushion in dermatological diagnostic ultrasound: A new method. Dermatologica 164:357–359

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Miyauchi, S., Miki, Y. Normal human skin echogram. Arch Dermatol Res 275, 345–349 (1983). https://doi.org/10.1007/BF00417209

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00417209

Key words

Navigation