Biomechanische Untersuchungen zur Osteosynthese kleiner menschlicher Röhrenknochen mit Kleinknochenplatten

Biomechanical tests on osteosynthesis with small-bone-plates

  • Published:
Archiv für orthopädische und Unfall-Chirurgie, mit besonderer Berücksichtigung der Frakturenlehre und der orthopädisch-chirurgischen Technik Aims and scope Submit manuscript

Summary

Plating in handsurgery has become a more frequently used method since the special instruments of the Swiss AO and the self-compression plates of Mittelmeier (made by Osteo AG) have been introduced. The results of biomechanical measurements, comparing the interfragmental compression power and tensile strength of the small-fragment-plates of the AO with the crescent-formed plates of Mittelmeier are reported. The compression power of the first reach their maximum by 8 kp, the latter an average of 20 kp. A gapping of the fracture occures under a deflection-momentum of 4 kp · cm using AO-plates and 10 kp · cm using the crescent-formed plates. The bending stiffness under deflection momentum to the off side of the plate is in the crescent plate 10 times higher. Only an angulating bending in the middle gives in both plates an all over good contact to the fragments. Finger osteosyntheses are very rigid against a deflection momentum in the level of the plate. (Regarding that, we fixe the plate sidewise on the bone.) Our conclusion is, that the better biomechanical stability of the self-compression plates — Mittelmeier-plates — is a result of the higher compression powers.

Zusammenfassung

Seit Verwendung des Instrumentariums der Schweizer AO und der selbstspannenden Druckplatte nach Mittelmeier (Osteo AG) wird auch in der Handchirurgie die offene Osteosynthese mit Kleinknochenplatten zahlreicher durchgeführt. Die Kleinknochenplatten der AO mit Rundlöchern und die Kleinknochenplatten nach Mittelmeier mit selbstspannenden Drucklöchern und Mondprofil wurden einer biomechanischen Untersuchung zur Messung der interfragmentären Kompressionskraft und der Biegestabilität unterzogen. Mit den Rundlochplatten der AO kann eine maximale Kompressionskraft von 8 kp erreicht werden, dagegen mit den Mondprofilplatten nach Mittelmeier eine mittlere Kompressionskraft von 20 kp. Zum Aufklaffen des gesamten Bruchspaltes führt bei der Kleinfragmentplatte der AO ein Biegemoment von 4 kp · cm, dagegen bei der Mondprofilplatte erst ein Biegemoment von 10 kp · cm. Die Biegesteifigkeit bei plattenabseitig gerichtetem Biegemoment ist bei der Mondprofilplatte nach Mittelmeier 10fach höher. Die Untersuchungen zeigten weiterhin, daß erst mittig-winklige Hohlbiegung bei beiden Plattenarten vor dem Anlegen zu einem innigen Kontakt der Fragmente im gesamten Spaltbereich führt. Die Untersuchungen zeigten, daß die Fingerosteosynthesen gegen Biegemomente in Plattenebene sehr steif sind. Daraus wird von uns gefolgert, daß die Anlagerung der Plättchen im Bereich der Hand hochkantig, d. h. parallel zu der genannten Ebene, also seitlich am Knochen, angeschraubt werden sollten. Wir folgern weiter aus den Untersuchungen, daß die höhere biomechanische Festigkeit der selbstspannenden Druckplatte vom Typ Mittelmeier auf der stärkeren Dimensionierung und auf höheren, durch die Drucklochform bedingten Kompressionskräften beruht.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Bagby, G. E., Janes, J. M.: The effect of compression on the rate of fracture healing using a special plate. Amer. J. Surg. 95, 761 (1958)

    Google Scholar 

  • Bertolin, A.: L'impiego della mia placca a compressione per l'osteosintesi dei vari tipi di osteotomie intertrochanteriche di femore. Clin. Orthop. 18, 221 (1966)

    Google Scholar 

  • Bunnell, S.: Splinting the hand. Amer. Acad. Orthop. Surg. „Instructional Course Lectures“, Vol. 9, p. 233. Edwards 1952

    Google Scholar 

  • Danis, R.: Théorie et pratique de l'ostéosynthèse. Paris: Masson 1947

    Google Scholar 

  • Diehl, K.: Biomechanische Berechnungen und Untersuchungen zur Notwendigkeit der Hohlbiegung bei der Plattenosteosynthese. Arch. orthop. Unfall-Chir. 80, 247 (1974a)

    Google Scholar 

  • Diehl, K.: Festigkeitsberechnungen von Druckplattenosteosynthesen im Schaftbereich menschlicher Röhrenknochen. Arch. orthop. Unfall-Chir. 80, 127 (1974b)

    Google Scholar 

  • Diehl, K., Hanser, U., Hort, W.: Erfassung mechanischer Beanspruchungen von Skeletteilen bei der Osteosynthese durch direkte Messung am Knochen mittels Dehnungsmeßstreifen. Im Druck

  • Diehl, K., Mittelmeier, H.: Biomechanische Untersuchungen zur Hohlbiegung der Osteosyntheseplatten. Z. Orthop. 112, 314 (1974)

    Google Scholar 

  • Hess, H.: Die Spannungskräfte der Druckplattenosteosynthese. Bücherei des Orthopäden, Bd. 9. Stuttgart: Enke 1972

    Google Scholar 

  • Hess, H., Sonntag, K.: Praktische Anwendung selbstspannender Platten bei Frakturen, Osteotomien, Pseudarthrosen und Arthrodesen. Med. orthop. Tech. 4, 100 (1974)

    Google Scholar 

  • Hort, W.: Statische und dynamische Untersuchungen an Fingerarthrodesen. Im Druck

  • Iselin, M.: Chirurgie der Hand. Atlas der Operationstechnik. Stuttgart: Thieme 1965

    Google Scholar 

  • Lambotte, A.: Le traitement des fractures. Paris: Masson 1907

    Google Scholar 

  • Magnus, G.: Zur Technik der Knochennaht. Zbl. Chir. 40, 2514 (1926)

    Google Scholar 

  • Mittelmeier, H.: Prinzipien der Osteosynthese mit „selbstspannenden Platten“. Med. orthop. Tech. 4, 90 (1974)

    Google Scholar 

  • Mittelmeier, H.: Kompressionsosteosynthese der frischen geschlossenen Unterschenkelschaftfrakturen mit Verschraubung und Verplattung. Hefte Unfallheilk. 117, 68 (1974)

    Google Scholar 

  • Müller, M. E., Allgöwer, M., Willenegger, H.: Manual der Osteosynthese. Berlin-Heidelberg-New York: Springer 1969

    Google Scholar 

  • Pannike, A.: Osteosynthese in der Handchirurgie. Berlin-Heidelberg-New York: Springer 1972

    Google Scholar 

  • Perren, S. M., Allgöwer, M., Ehrsam, R., Ganz, R., Matter, P.: Clinical experience with a new compression plate “DCP”. Acta orthop. scand., Suppl. 125, 31 (1969)

    Google Scholar 

  • Tamai, T., Hoshiko, W.: Zit. nach Mittelmeier

  • Venable, C. S.: An impacting bone plate to attain close coaptation. Amer. Surg. 133, 808 (1951)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hort, W., Diehl, K. Biomechanische Untersuchungen zur Osteosynthese kleiner menschlicher Röhrenknochen mit Kleinknochenplatten. Arch orthop Unfall-Chir 83, 37–44 (1975). https://doi.org/10.1007/BF00415979

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00415979

Navigation