Summary
Cardio-respiratory functions were recorded in 18 glass bangle workers (Belanias) who worked near the belan furnace continuously for 2 h. The workers were exposed to high ambient temperature (tDB 38.2°C ± 3.4°C) and thermal radiation (tG 46.2°C ±5.1°C) during their work. The physiological responses recorded after the work spell at 1(R1) 3 (R3) and 5 (R5) minute intervals exhibited incomplete recovery. The oral temperature remained significantly high (0.74°F ±0.27°F) even at RS and never reached pre-work value. Similarly the heart rate values remained very high (26.4 ± 5.4 beats/min) at R1, (10.7 ± 3.9 beats/min) at R3 and (4.01 ± 2.4 beats/min) at R5 periods during recovery, thereby showing that heart rate did not regain the pre-work status. The incomplete recovery in heart rate revealed cardiac stress in the exposed workers. Besides the cardiac stress, the cardiac cost of the work under the prevailing hot conditions in the glass bangle industry was very high, adding further to circulatory strain in these workers. Almost all the exposed workers were found to have hyperventilation syndrome characterized by increased respiratory frequency and tidal volume resulting in ventilatory stress induced by physical and physiological heat.
Similar content being viewed by others
References
Best CH, Taylor NB (1979) The physiological basis of medical practice. 10th edition, by J. R. Brobeck, Baltimore, Williams & Wilkins, 679 pp
Brouha L (1960) Physiology in industry. Pergamon Press, London, 96 pp
Brouha L (1967) Physiology in industry. Pergamon Press, New York
Chakrabarty BK, Ghosh HN, Sahane SN (1972) Modern human physiology, by S. Chand & Co, Interscience Press, Calcutta, India, 547 pp
Christensen EH (1963) Man at work — outline of work physiology issued by Chief Advisor Factories, Ministry of Labour and Employment, New Delhi
DuBois D, DuBois EF (1915) Arch Industr Med 15:868 pp
Fuller FH, Smith PE (1980) The effectiveness of preventive work practices in a hot workshop. In: Dukes-Dubos FN, Henschel A (eds) Proceedings of a NIOSH workshop on recommended heat stress standards. Cincinnati. U.S. Dept. of Health and Human Services, Center for disease control, publication no. DDHS, 81–108
Fuller FH, Smith PE (1981) Evaluation of heat stress in a hot workshop by physiological measurements. Am Ind Hyg Assoc J 42:37–47
Gaudio R, Abramson N (1968) Heat induced hyperventilation. J Appl Physiol 25:742–746
Jensen RC, Dukes-Dobos FN (1976) Validation of proposed limits for exposure to industrial heat. In: Hovarth SM, Jensen RC (eds) Standards of occupational exposure to hot environments. Proceedings of symposium, US Dept. of Health, Education and Welfare, NIOSH publication no. DHEW 76–100
Miller EA (1953) The physiological basis of rest pauses in heavy work. J Exp Physiol 38:205–215
NIOSH (1986) Criteria for a recommended standard — occupational exposure to hot environments. Revised criteria, U.S. Dept. of Health and Human Services, Center for disease control, publication no. DHHS, 86–113
Rastogi SK, Gupta BN, Husain T, Mathur N (1987) A study of thermal environment in glass bangle industry. Ind J Occup Hlth 30:69–77
Rowell LB, Brengelmann I, Murray JA (1969) Cardio-vascular response to sustained high skin temperature in resting men. J Appl Physiol 27:673–680
Samanta A, Datta SR, Roy BN (1983) Recovery heart rate as a tool for the assessment of work stress. Paper presented at the Int Sym Appl Physiol Ergonomics held at Regional Labour Office, Calcutta, 17 August-19 August
Saxton C (1975) Respiration during heat stress. Aviat Space Environ Med 46:41–46
Siconolfi SF, Garber CE, Laster TM, Carleton RA (1985) A simple, valid step test for estimating maximal oxygen uptake in epidemiological studies. Am J Epidemiol 121:382–390
Verghese CA, Sinha KC, Mani KV (1969) Studies on recovery from heat induced physiological strain. J Aviat Med Soc Ind 39:51–57
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Rastogi, S.K., Gupta, B.N., Husain, T. et al. Cardio-respiratory studies on glass bangle workers. Int. Arch Occup Environ Heath 61, 487–493 (1989). https://doi.org/10.1007/BF00386484
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00386484