Summary
The concentration of n-hexane in urine was determined in 30 subjects occupationally exposed to n-hexane (median value 59.6 mg/m3) in a shoe factory. The measurement of the substance was performed by means of a Hewlett-Packard 5880 gas chromatograph supplied with a Hewlett-Packard 5970 Mass Selective Detector. The analyses were performed by the head space method (constant volume method, after determination of the urine partition coefficient by the multiple phase equilibration method). The authors found a significant correlation between the n-hexane urine concentrations (μg/1, Cu) and the n-hexane environmental concentrations (mg/m3, Ci) (r = 0.84; Cu = 0.0669 x Ci + 0.8396).
Similar content being viewed by others
References
Capodaglio E, Catenacci G (1978) Rischi chimici-Schede informative. La Goliardica Pavese Editor, Pavia
Couri D, Abdel-Rahman MS, Hetland LB (1978) Biotransformation of n-hexane and methyl n-butyl ketone in guinea pigs and mice. Am Ind Hyg Assoc J 39:295–300
Di Vincenzo GD, Kaplan CJ, Dedinas J (1976) Characterization of the metabolites of methyl n-butyl ketone, methyl iso-butyl ketone and methyl ethyl ketone in guinea pig serum and their clearance. Clin Toxicol 13:371–376
Iwata M, Takeuchi Y, Hisanaga N, Ono Y (1983) Changes of n-hexane metabolites in urine of rats exposed to various concentrations of n-hexane and to its mixture with toluene or MEK. Int Arch Occup Environ Health 53:1–8
Iwata M, Takeuchi Y, Hisanaga N, Ono Y (1983) A study of biological monitoring of n-hexane exposure. Int Arch Occup Environ Health 51:253–260
Lautenberger W, Keing EV, Morello JA (1981) Theory of passive monitors. In: Kelley WD (ed) “Dosimetry for chemical and physical agents.” Published by ACGIH, 1,91
McAuliffe C (1971) GC determination of solutes by multiple phase equilibration. Chem Tech [Jan] 46
Miyasaka M, Kumai M, Koizumi A, Watanabe T, Kurasako K, Sato K, Iheda M (1982) Biological monitoring of occupational exposure to methyl ethyl ketone by means of urinalyis for methyl ethyl ketone itself. Int Arch Occup Environ Health 50:131–137
Mutti A, Falzoi M, Lucertini S, Arfini G, Zignani M, Lombardi S, Franchini I (1985). n-Hexane metabolism in occupationally exposed workers. Br J Ind Med [in press]
Perbellini L, Brugnone F, Pavan I (1980) Identification of the metabolites of n-hexane, cyclohexane and then isomers in men's urine. Toxicol Appl Pharmacol 53:220–228
Perbellini L, Brugnone F, Sivestri R, Gaffuri E (1981) Measurement of the urinary metabolites of n-hexane, cyclohexane and their isomers by gas chromatography. Int Arch Occup Environ Health 48:99–106
Pezzagno G, Ghittori S, Imbriani M, Capodaglio E (1982) La misura dei coeicienti di solubility degli aeriformi nel sangue o in altri liquidi solventi. Nota 1: i metodi. G Ital Med Lav 4:251–261
Pezzagno G, Ghittori S, Imbriani M, Capodaglio E (1983) La misura dei coefficients di solubility degli aeriformi nel sangue o in altri liquidi solventi. Nota 2: i solvents di largo impiego industriale. G Ital Med Lav 2:49–63
Sedivec V, Mraz M, Flek J (1981) Biological monitoring of persons exposed to methanol vapours. In Arch Occup Environ Health 48:257–271
Veulemans H, Van Veem E, Janssens H, Masschelein R, Leptat A (1982) Experimental human exposure to n-hexane. Int Arch Occup Environ Health 49:251–263
Author information
Authors and Affiliations
Additional information
This work was supported by the research funds given to Fondazione Clinica del Lavoro, Pavia by the Health Council
Rights and permissions
About this article
Cite this article
Imbriani, M., Ghittori, S., Pezzagno, G. et al. n-Hexane urine elimination and weighted exposure concentration. Int. Arch Occup Environ Heath 55, 33–41 (1984). https://doi.org/10.1007/BF00378065
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00378065