Skip to main content
Log in

Intra-arterial DSA: early experience with a 10242 matrix

  • Uses of Technique
  • Published:
Neuroradiology Aims and scope Submit manuscript

Summary

Twenty patients were studied with intraarterial digital subtraction angiography (IA DSA), utilizing a 10242 matrix memory. Acquisition of the images was through a prototype television camera incorporating a finely focused electron beam. In five cases, comparison between a 512×512 (5122) matrix acquisition and a 1024×1024 (10242) matrix acquisition mode was made, with injections occurring in the same vessel in the same patient. The clinical material demonstrated no significant improvement in image quality at the 41/2 as well as the 6 inch image intensifier (II) modes. However, the 10242 matrix combined with the 9 inch II mode showed foci of disease and normal anatomy with detail not always seen on the 9 inch II when a 5122 matrix was used. In no case, however, was the basic diagnosis missed with the 5122 matrix. Spatial resolution, as measured from lead bar test pattern images, demonstrated that the 10242 matrix allows a 70% or greater improvement in spatial resolution over the 5122 for the 41/2, 6 and 9 inch II modes. For a given mode the radiation dose was held constant for the two matrix sizes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Strother CM, Sackett JF, Crummy AB (1980) Clinical applications of computerized fluoroscopy. Radiology 136: 781–781

    Google Scholar 

  2. Christenson P, Ovitt TW, Fiser HD (1980) Intravenous angiography using digital video subtraction: intravenous cervicocere-brovascular angiography. AJNR 1: 379–386

    Google Scholar 

  3. Meaney TF, Weinstein MA, Buonocore E (1980) Digital subtraction angiography of the human cardiovascular system. AJR 135: 1153–1160

    Google Scholar 

  4. Brant-Zawadzki M, Gould R, Norman D, Newton TH, Lane B (1983) Digital subtraction cerebral angiography by intra-arterial injection: Comparison with conventional angiography. AJR 140: 347–353

    Google Scholar 

  5. Crummy AB, Stieghorst MF, Turski PA, Strother CM, Lieberman RP, Sackett JF, Turnipseed WD, Detmer DE, Mistretta CA (1982) Digital subtraction angiography: current status and use of intra-arterial injection. Radiology 145: 303–307

    Google Scholar 

  6. Weinstein MA, Pavlicek WA, Modic MT, Duchesneau PM (1983) Intra-arterial digital subtraction angiography of the head and neck. Radiology 147: 717–724

    Google Scholar 

  7. Enzman DR, Brody WR, Djang WT, Riederer S, Keyes G, Collins W, Pele N (1983) Intra-arterial digital subtraction spinal angiography. AJNR 4: 25–26

    Google Scholar 

  8. Ovitt T, Capp MP, Christenson P (1979) Development of a digital video subtraction system for intravenous angiography. Recent and future developments in medical imaging II. Proc SPIE 206: 73–76

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kelly, W.M., Brant-Zawadzki, M., Schardt, M.A. et al. Intra-arterial DSA: early experience with a 10242 matrix. Neuroradiology 27, 70–76 (1985). https://doi.org/10.1007/BF00342520

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00342520

Key words

Navigation