Methods are described for non-invasive, computer-assisted serial scanning throghout the human brain during eight minutes of inhalation of 27%–30% Xenon gas in order to measure local cerebral blood flow (LCBF). Optimized Xenonenhanced computed tomography (XeCT) was achieved by 5-second scanning at one-minute intervals utilizing a state-of-the-art CT scanner and rapid delivery of Xenon gas via a face mask. Values for local brain-blood partition coefficients (Lλ) measured in vivo were utilized to calculate LCBF values. Previous methods assumed Lλ values to be normal, introducing the risk of systematic errors, because Lλ values differ throughout normal brain and may be altered by disease. Color-coded maps of Lλ and LCBF values were formatted directly onto CT images for exact correlation of function with anatomic and pathologic observations (spatial resolution: 26.5 cubic mm). Results were compared among eight normal volunteers, aged between 50 and 88 years. Mean cortical gray matter blood flow was 46.3±7.7, for subcortical gray matter was 50.3±13.2 and for white matter was 18.8±3.2. Modern CT scanners provide stability, improved signal to noise ratio and minimal radiation scatter. Combining these advantages with rapid Xenon saturation of the blood provides correlations of Lλ and LCBF with images of normal and abnormal brain in a safe, useful and non-invasive manner.
Similar content being viewed by others
References
Lassen NA (1981) Regional cerebral blood flow measurements in stroke: The necessity of a tomographic approach. J Cereb Blood Flow Metab 1:141–142
Meyer JS (1986) Clinical value and costs for diagnostic testing for evaluation of patients with stroke: Methods for measuring cerebral blood flow. In: Lechner H, Meyer JS, Ott E (eds) Cerebrovascular disease: Research and clinical management, vol 1. Elsevier, Amsterdam, pp 307–312
Lassen NA, Henriksen L, Paulson O (1981) Regional cerebral blood flow in stroke by 133Xenon inhalation and emission tomography. Stroke 12:284–288
Kuhl DE, Barrio JR, Huang SC, Selin C, Ackermann RF, Lear JL, Wu JL, Lin TH, Phelps ME (1982) Quantifying local cerebral blood flow by N-isopropyl-p-[123I] iodoamphetamine (IMP) tomography. J Nucl Med 23:196–203
Meyer JS (1981) Application of studies of cerebral blood flow: Ischemic cerebravascular disease. In: Moossy J, Reinmuth OM (eds) Cerebrovascular diseases: Twelfth research (Princeton) conference. Raven, New York, pp 125–141
Meyer JS, Hayman LA, Yamamoto M, Sakai F, Nakajima S (1980) Local cerebral blood flow measured by CT after stable Xenon inhalation. AJNR 1:213–225
Meyer JS, Hayman LA, Amano T, Nakajima S, Shaw T, Lauzon P, Derman S, Karacan I, Harati Y (1981) Mapping local blood flow of human brain by CT scanning during stable Xenon inhalation. Stroke 12:426–436
Meyer JS, Okayasu H, Tachibana H, Okabe T (1984) Stable Xenon CT CBF measurements in prevalent cerebravascular disorders (stroke). Stroke 15:80–90
Drayer BP (1981) Functional applications of CT of the central nervous system. AJNR 2:495–510
Amano T, Meyer JS, Okabe T, Shaw T, Mortel KF (1982) Stable Xenon CT cerebral blood flow measurements computed by a single compartment-double integration model in normal aging and dementia. J Comput Assist Tomogr 6:923–932
Gur D, Wolfson Sk Jr, Yonas H, Good WF, Shabason L, Latchaw RE, Miller DM, Cook EE (1982) Progress in cerebrovascular disease: Local cerebral blood flow by Xenon enhanced CT. Stroke 13:750–758
Yonas H, Good WF, Gur D, Wolfson SK Jr, Latchaw RE, Good BC, Leanza R, Miller SL (1984) Mapping cerebral blood flow by Xenon-enhanced computed tomography: Clinical experience. Radiology 152:435–442
Hata T, Gotoh F, Ebihara S, Shinohara T, Kawamura J, Takashima S (1985) Three dimensional local cerebrovascular CO2 responsiveness by cold Xenon method. In: Meyer JS, Lechner H, Reivich M, Ott EO (eds) Cerebral vascular disease 5: Proceedings of the World Federation of Neurology 12th International Salzburg Conference. Elsevier, Amsterdam, pp 141–147
Hata T, Meyer JS, Tanahashi N, Ishikawa Y, Imai A, Shinohara T, Velez M, Fann WE, Kandula P, Sakai F (1987) Three-dimensional mapping of local cerebral perfusion in alcoholic encephalopathy with and without Wernicke-Korsakoff syndrome. J Cereb Blood Flow Metab 7:35–44
Kitagawa Y, Meyer JS, Tanahashi N, Rogers RL, Tachibana H, Kandula P, Dowell RE, Mortel KF (1985) Cerebral blood flow and brain atrophy correlated by Xenon contrast CT scanning. Comput Radiol 9:331–340
Kety SS (1951) The theory and applications of the exchange of inert gas at the lungs and tissues. Pharmacol Rev 3:1–41
Tomita M, Gotoh F (1981) Local cerebral blood flow values as estimated with diffusible tracers: Validity of assumptions in normal and ischemic tissue. J Cereb Blood Flow Metab 1: 403–411
Rottenberg DA, Lu HC, Kearfott KJ (1982) The in vivo autoradiographic measurement of regional cerebral blood flow using stable Xenon and computerized tomography: The effect of tissue heterogeneity and computerized tomography noise. J Cereb Blood Flow Metab 2:173–178
Gur D, Shabason L, Wolfson SK Jr, Yonas H, Good WF (1983) Measurement of local cerebral blood flow by Xenonenhanced computerized tomography imaging: A critique of an error assessment. J Cereb Blood Flow Metab 3:133–135
Herscovitch P, Raichle ME (1983) Effect of tissue heterogeneity on the measurement of cerebral blood flow with equilibrium C15O2 inhalation technique. J Cereb Blood Flow Metab 3:407–415
Eichling J (1979) Noninvasive methods of measuring regional cerebral blood flow. In: Price TR, Nelson E (eds) Cerebrovascular diseases: Eleventh Princeton conference. Raven, New York, pp 51–56
Cann CE (1987) Quantitative computed tomography for bone mineral analysis: Technical considerations. In: Genant HK (ed) Osteoporosis update 1987. Radiology Research and Edueation Foundation, San Francisco, pp 131–144
Oravez WT, Meyer JS, Imai A, Shinohara T, Timpe G, Deville T, Suess C (1986) Technical optimization for determining local cerebral blood flow using dynamic quantitative CT and Xe5/O2 (g) contrast material. Radiology 161 (P):345
Obrist WD, Thomspson HK Jr, King CH Wang HS (1967) Determination of regional cerebral blood flow by inhalation of 133-Xenon. Circ Res 20:124–135
Kelcz F, Hilal SK, Hartwell P, Joseph PM (1978) Computed tomographic measurement of the Xenon brain-blood partition coefficient and implication for regional cerebral blood flow: A preliminary report. Radiology 127:385–392
Marquardt DW (1963) An algorithm for least-squares estimation of non-linear parameters. J Soc Indust Appl Math 11: 431–441
Rogers RL, Meyer JS, Shaw TG, Mortel KF, Hardenberg JP, Zaid RR (1983) Cigarette smoking decreases cerebral blood flow suggesting increased risk for stroke. JAMA 250: 2796–2800
Meyer JS, Judd BW, Tawaklna T, Rogers RL, Mortel KF (1986) Improved cognition after control of risk factors for multi-infarct dementia. JAMA 265:2203–2209
Kearfott KJ, Lu HC, Rottenberg DA, Deck MDF (1984) The effects of CT drift on Xenon/CT measurement of regional cerebral blood flow. Med Phys 11:686–689
Good WF, Gur D (1987) The effect of computed tomography noise and tissue heterogeneity on cerebral blood flow determination by Xenon-enhanced computed tomography. Med Phys 14:557–561
Lenzi GL, Frackowiak RSJ, Jones T, Heather JD, Lammertsma AA, Rhodes CG, Pozzilli C (1981) CMRO2 and CBF by the oxygen-15 inhalation technique: Results in normal volunteers and cere rovascular patients. Eur Neurol 20:285–290
Tachibana H, Meyer JS, Okayasu H, Kandula P (1984) Changing topographic patterns of human cerebral blood flow with age measured by Xenon CT. AJNR 5:139–146
Veall N, Mallett BL (1965) The partition of trace amounts of Xenon between human blood and brain tissues at 37°C. Phys Med Biol 10:375–380b
Drayer BP, Gur D, Yonas H, Wolfson SK Jr, Cook EE (1980) Abnormality of the Xenon brain: blood partition coefficient and blood flow in cerebral infarction: An in vivo assessment using transmission computed tomography. Radiology 135: 349–354
Huebner U, Schuier F, Haertel C, Hartmann A, Dettmers C (1987) In vivo determination of brain-blood partition coefficient of Xenon in the monkey. J Cereb Blood Flow Metab 7 [Suppl 1]: S548
Duara R (1985) Brain region localization in positron emission tomographic images. J Cereb Blood Flow Metab 5:343–344
Duara R, Grady C, Haxby J, Ingvar D, Sokoloff L, Margolin RA, Manning RG, Cutler NR, Rapoport SI (1984) Human brain glucose utilization and cognitive function in relation to age. Ann Neurol 16:702–713
Tachibana H, Meyer JS, Rose JE, Kandula P (1984) Local cerebral blood flow and partition coefficients measured in cerebral astrocytomas of different grades of malignancy. Surg Neurol 21:125–131
herscovitch P, Raichle ME (1985) What is the correct value for the brain-blood partition coefficient for water? J Cereb Blood Flow Metab 5:65–69
Jones SC, Greenberg JH, Reivich M (1982) Error analysis for the determination of cerebral blood flow with the continuous inhalation of 15O-labeled carbon dioxide and positron emission tomography. J Comput Assist Tomogr 6:116–124
Winkler S, Turski P (1985) Potential hazards of Xenon inhalation. AJNR 6:974–975
Obrist WD, Jaggi JL, Harel D, Smith DS (1985) Effect of stable Xenon inhalation on human CBF. J Cereb Blood Flow Metab 5 [Suppl 1]:S557-S558
Fatouros PP, Kishore PRS, Hall JA Jr, Wist AO, Dewitt DS, Marmarou A, Keenan R, Kontos H (1985) Comparison of improved stable Xenon/CT method for cerebral blood flow measurements with radiolabeled microsphere techniques. Radiology 157 (P):334
Hellman RS, Collier BD, Tikofsky RS, Kilgore DP, Daniels DL, Haughton VM, Walsh PR, Cusick JF, Saxena VK, Palmer DW, Isitman AT (1986) Comparison of single-photon emission computed tomography with [123I] iodoamphetamine and Xenon-enhanced computed tomography for assessing regional cerebral blood flow. J Cereb Blood Flow Metab 6: 747–755
Wozney P, Yonas H, Latchaw RE, Gur D, Good W (1985) Central hermination revealed by focal decrease in blood flow without elevation of intracranial pressure: A case report. Neurosurgery 17:641–644
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Meyer, J.S., Shinohara, T., Imai, A. et al. Imaging local cerebral blood flow by Xenon-enhanced computed tomography — Technical optimization procedures. Neuroradiology 30, 283–292 (1988). https://doi.org/10.1007/BF00328177
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00328177