Skip to main content
Log in

Iron, manganese, copper and titanium in welding fume dust on filters for internal and external quality assurance

  • Clinical Chemistry And Occupational Health
  • Published:
Fresenius' Journal of Analytical Chemistry Aims and scope Submit manuscript

Summary

Filters charged with welding fume dust were developed and produced for internal and external quality assurance to evaluate and improve the performance of analytical methods used for monitoring iron, manganese, copper and titanium in the working environment. The filters were simultaneously loaded, using a Sputnic air sampling unit containing 100 cellulose nitrate filters. The welding fume dust was collected in industrial working conditions where Metal Inert Gas welding in construction steel was being carried out. The metal concentrations on the filters were close to the metal concentrations from environmental and industrial exposure. The homogeneity of the filter materials was evaluated to document the suitability of the air sampler in producing quality control materials. The filters were homogeneous within 5.0–12.7% according to amount of metal. The welding fume dust loaded on the filters was (0.2021±0.0093 mg/filter) and the amounts of metals loaded on the filters were (34.6±6.4 μg/filter, 16.0±0.8 μg/filter, 2.4±0.1 μg/filter) for iron, manganese and titanium, respectively. Normalizing the amount of metal according to the welding fume dust improved the homogeneity. The most satisfactory results were obtained for manganese and titanium, for which within batch variation was below 6.3%. The Sputnic air sampler was shown to be suitable in preparing quality control materials, although a few improvements are needed for future experiments, such as the method of charging the dust and rules for outlier exclusion.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. PAT Proficiency Analytical Testing Program (1990) National Institute for Occupational Safety and Health, NIOSH, Cincinnati

    Google Scholar 

  2. BCR Reference Materials (1991) Commission of the European Communities, Bruxelles Report EUR 11448 EN

  3. Anglov JTB, Holst E, Christensen JM (1992) Int Arch Occup (In press)

  4. Christensen SL, Anglov JTB, Christensen JM, Olsen E, Poulsen OM (1993) Fresenius J Anal Chem

  5. Bjørgo R, Fjeldstad P, Nagy K, Thomassen Y (1980) Parallelfiltre fra arbeidsatmosfæren i aluminiumsindustrien for interlaboratoriekontroll av analyse på PAH og flurid. Institute of Occupational Health, Oslo

    Google Scholar 

  6. Olsen IB, Holst E (1991) Analyst (In press)

  7. Minitab Reference Manual (1989) Release 7, Boston

  8. Armitage P, Berry G (1987) Statistical methods in medical research, Second Edition, Cambridge

  9. Miller I, Freund JE (1985) Probability and statistics for engineers. Third edition

  10. Conover WJ (1971) Practical nonparametric statistics

  11. ISO 35 (1988) International organization for standardization

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Anglov, J.T.B., Holst, E., Dyg, S. et al. Iron, manganese, copper and titanium in welding fume dust on filters for internal and external quality assurance. Fresenius J Anal Chem 345, 335–339 (1993). https://doi.org/10.1007/BF00322625

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00322625

Keywords

Navigation