Two different experimental methods for the calibration of glass electrodes for H+ concentration are analysed: strong acid—strong base titration and addition of the strong base or acid to the solvent. Possible systematic errors in acid or base concentrations used for calibration affect in a different way the linear relationship between the cell potential and the logarithm of the hydrogen ion concentration in each case. We have examined how such errors influence the slope of the calibration curve by using a programme that simulates the calibration procedure and we have compared this analysis with some experimental results previously obtained.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Linder PW, Torrington RG, Willians DR (1984) Analysis using glass electrodes, Open Univ Press

  2. May P, Willians DR, Linder PW, Torrington RG (1982) Talanta 29:249

    Google Scholar 

  3. Braibanti A, Ostacoli G, Paoleti P, Pettit D, Sammartano S (1987) Pure Appl Chem 12:1721

    Google Scholar 

  4. Bates RG (1973) Determination of pH, theory and practice, Wiley, New York, pp 364–365

    Google Scholar 

  5. Machado A, Vasconcelos T (1986) Rev Port Quim 28:120

    Google Scholar 

  6. Ruckdeschel FR (1981) Basic scientific subroutines, Vol. 1, McGraw-Hill, New York

    Google Scholar 

  7. May P, Murray K (1988) Talanta 12:933

    Google Scholar 

  8. Sastre de Vicente M, Santaballa A (1989) Meeting of the Spanish Electrochemistry Group, September 1989

  9. Antelo J, Arce F, Casado J, Sastre de Vicente M, Varela A (1984) J Chem Eng Data 29:10

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Fiol, S., Arce, F., Armesto, X.L. et al. Analysis of systematic errors in calibrating glass electrodes with H+ as a concentration probe. Fresenius J Anal Chem 343, 469–472 (1992). https://doi.org/10.1007/BF00322151

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00322151

Keywords

Navigation