Skip to main content
Log in

Kalt gefüllte Mikroglaskapillaren und ihre elektrophysiologisch relevanten Eigenschaften

Cold-filled microglascapillaries and their properties relevant for electrophysiology

  • Published:
Zeitschrift für vergleichende Physiologie Aims and scope Submit manuscript

Summary

A method is described for direct filling of microglascapillaries (0.1 μm tip diameter) with any kind of medium at room temperature. The properties of electrodes filled with a 3-molar KCl-solution are studied. Tip potential of 84% of those electrodes, measured in 0.9% NaCl-solution, are ≦6 mV. The mean electrode resistance, measured in 3-molar KCl-solution is 8.8 MegOhm. The resistance fluctuations of a single electrode within a time of two weeks are ±5%. By changing the bath-solution from 3-molar KCl to 0.9% NaCl the resistance increases by a factor of 2.3 in the mean. The electrode resistances calculated from electron microscopical plates agree well with the measured ones. The changes of resistance occuring during a current flow up to ±10−7 A are unsymmetrical but reversible.

Zusammenfassung

Es wird eine, Methode zur direkten Füllung von Mikroglaskapillaren (0,1 μm Spitzendurchmesser) mit beliebigem Füllmedium bei Zimmertemperatur beschrieben. Untersucht werden die Eigenschaften von mit 3 molarer KCl-Lösung gefüllten Elektroden. Die Spitzenpotentiale von 84% solcher Elektroden, gemessen gegen 0.9% ige NaCl-Lösung, sind ≦6 mV. Der mittlere Elektrodenwiderstand, gemessen gegen 3molare KCl-Lösung beträgt 8,8 MegOhm. Die Schwankungen der einzelnen Elektrodenwiderstände in einem Zeitraum von zwei Wochen liegen innerhalb von ±5% um ihren Mittelwert. Beim Umsetzen der Elektroden von 3 molarer KCl-Lösung in 0,9% ige NaCl-Lösung erhöht sich ihr Widerstand im Mittel um den Faktor 2,3. Die aus elektronenmikroskopischen Aufnahmen errechneten Elektrodenwiderstände stimmen mit den gemessenen überein. Die während eines Stromflusses bis ±10−7 A auftretenden Widerstandsveränderungen sind unsymmetrisch, aber reversibel.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Adrian, R. H.: The effect of internal and external potassium concentration on the membrane potential of frog muscle. J. Physiol. (Lond.) 133, 631 (1956).

    Google Scholar 

  • Burkhardt, D.: Die Übertragungseigenschaften elektrophysiologischer Versuchsanordnungen. Z. Biol. 109, 297 (1957).

    Google Scholar 

  • Burkhardt, D.: Ultramikroelektroden aus Glas, ihre Herstellung und Verwendung bei elektrophysiologischen Messungen. Glas-u.Instrumententechnik 3, 115 (1959).

    Google Scholar 

  • Frank, K., Becker, M. C.: Microelectrodes for recording and stimulation. In: Physical techniques in biological research, vol. V (W. L. Nastuk, ed.) New York: Acad. Press 1964.

    Google Scholar 

  • Lang, E. P.: Kolloid-Z. 70, 226 (1935).

    Google Scholar 

  • Tasaki, I., Polley, E. H., Orrego, F.: Action potentials from individual elements in cat geniculate and striate cortex. J. Neurophysiol. 17, 454 (1954).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Die Arbeit wurde durch Mittel gefördert, die die Deutsche Forschungsgemeinschaft Herrn Prof. Dr. H. Autrum zur Verfügung stellte.

Für das Anfertigen der elektronenmikroskopischen Aufnahmen bin ich Herrn Dr. F. Barth zu Dank verpflichtet.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zettler, F. Kalt gefüllte Mikroglaskapillaren und ihre elektrophysiologisch relevanten Eigenschaften. Z. Vergl. Physiol. 67, 423–435 (1970). https://doi.org/10.1007/BF00297910

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00297910