Value of static pulmonary compliance in predicting mortality in patients with acute respiratory failure

  • Original Articles
  • Published:
Intensive Care Medicine Aims and scope Submit manuscript

Abstract

The measurement of static pulmonary compliance by means of pressure-volume curves is an useful tool in the management of patients with acute respiratory failure. On admission to our Intensive Care Unit, we calculated the static pulmonary compliance values from the pressure-volume curve in 55 severe acute respiratory failure patients under mechanical ventilation. A predictive model, based on static pulmonary compliance measured on the deflation of the pressure-volume curve and patients' age, was developed using a function derived by stepwise discriminant analysis. Thirty-six of the 40 patients (90%) in the learning sample and 12 of the 15 patients (80%) in the test sample were correctly classified into survivors or non-survivors. The overall classification demonstrated an accuracy of 88% (48 of 55 patients). We conclude that the value of static pulmonary compliance can be an useful prognostic factor in patients with severe acute respiratory failure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bartlett RH, Gazzaniga AB, Wilson AF, Medley T, Wetmore N (1975) Mortality prediction in adult respiratory insufficiency. Chest 67:680

    Google Scholar 

  2. Bartlett RH, Morris AH, Fairley HB, Hirsch R, O'Connor N, Pontoppidan H (1986) A prospective study of acute hypoxic respiratory failure. Chest 89:684

    Google Scholar 

  3. Bone RC (1976) Compliance and dynamic characteristics curves in acute respiratory failure. Crit Care Med 4:173

    Google Scholar 

  4. Gattinoni L, Pesenti A, Caspani ML, Pelizzola A, Mascheroni D, Marcolin R, Iapichino G, Langer M, Agostoni A, Kolobow T, Melrose DG, Damia G (1984) The role of total static lung compliance in the management of severe ARDS unresponsive to conventional treatment. Intensive Care Med 10:121

    Google Scholar 

  5. Gattinoni L, Pesenti A, Mascheroni D, Marcolin R, Fumigalli R, Rossi F, Iapichino G, Romagnoli G, Uziel L, Agostoni A, Kolobow T, Damia G (1986) Low-frequency positive-pressure ventilation with extracorporeal CO2 removal in severe acute respiratory failure. JAMA 256:881

    Google Scholar 

  6. Mancebo J, Calaf N, Benito S (1985) Pulmonary compliance measurement in acute respiratory failure. Crit Care Med 13:589

    Google Scholar 

  7. Matamis D, Lemaire F, Harf A, Brun-Buisson C, Ansquer JC, Atlan G (1984) Total respiratory pressure-volume curves in the adult respiratory distress syndrome. Chest 86:58

    Google Scholar 

  8. SPPSx user's guide (1983) A complete guide to SPPSx language and operations. McGraw-Hill, New York, p 623

    Google Scholar 

  9. Suter PM, Fairley HB, Isenberg MD (1975) Optimum end-expiratory airway pressure in patients with acute pulmonary failure. N Engl J Med 292:284

    CAS  PubMed  Google Scholar 

  10. Wiedeman HP, Matthay MA, Matthay RA (1984) Cardiovascular pulmonary monitoring in the intensive care unit, part 2. Chest 85:656

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mancebo, J., Benito, S., Martín, M. et al. Value of static pulmonary compliance in predicting mortality in patients with acute respiratory failure. Intensive Care Med 14, 110–114 (1988). https://doi.org/10.1007/BF00257461

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00257461

Key words

Navigation