Skip to main content
Log in

Urinary clearance of 113mIn-DTPA and 99mTc-(Sn)DTPA measured by external arm counting

  • Originals
  • Published:
Urological Research Aims and scope Submit manuscript

Summary

Single shot glomerular filtration rate measurements involving chelates (113mIn-DTPA, 99mTc-DTPA etc) assume direct loss from the plasma to urine via glomerular filtration and excretion. Inherent errors, due to considerable uptake of activity in tissue and uncertainty of complete bladder emptying are ignored and taking of half-hourly blood and urine samples involves patient discomfort. This paper describes a simple method of measuring urinary clearance of chelates using serial external arm counting which entails only an initial injection and takes into account tissue loss from plasma. The resultant plotted curve exhibits three phases, the first two depicting input and equilibration between plasma and tissue and the third and exponential part, which is a measure of the biological half-life of the chelate, being representative of the efficiency of renal glomerular filtration, the parameter to be measured. Results obtained, compared with single shot glomerular filtration rate measurements performed simultaneously, gave better correlation with clinical data including renography.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ditzel, J., Vestergaard, P., Brinklov, M.: Glomerular filtration rate determined by 51Cr-EDTA-complex. Scandinavian Journal of Urologya and Nephrology 5, 166 (1972)

    Google Scholar 

  2. Garnett, E. S., Parsons, V., Veall, N.: Measurement of glomerular filtration rate in man using a 51Cr-Edetic acid complex. Lancet 1967 I, 818

    Google Scholar 

  3. Maisey, M. N., Ogg, C. S., Cameron, J. S.: Measuring glomerular filtration rate. Lancet 1969 I, 733

    Google Scholar 

  4. Ram, M. D., Holroyd, H., Chisholm, G. D.: Measurement of glomerular filtration rate using 131I-diatrizoate. Lancet 1969 I, 397

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Macleod, M.A., Sampson, W.F. & Houston, A.S. Urinary clearance of 113mIn-DTPA and 99mTc-(Sn)DTPA measured by external arm counting. Urol. Res. 5, 71–74 (1977). https://doi.org/10.1007/BF00256844

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00256844

Key words

Navigation