Abstract
Objectives
To develop a convenient and rapid single-kidney CT-GFR technique.
Methods
One hundred and twelve patients referred for multiphasic renal CT and 99mTc-DTPA renal dynamic imaging Gates-GFR measurement were prospectively included and randomly divided into two groups of 56 patients each: the training group and the validation group. On the basis of the nephrographic phase images, the fractional renal accumulation (FRA) was calculated and correlated with the Gates-GFR in the training group. From this correlation a formula was derived for single-kidney CT-GFR calculation, which was validated by a paired t test and linear regression analysis with the single-kidney Gates-GFR in the validation group.
Results
In the training group, the FRA (x-axis) correlated well (r = 0.95, p < 0.001) with single-kidney Gates-GFR (y-axis), producing a regression equation of y = 1665x + 1.5 for single-kidney CT-GFR calculation. In the validation group, the difference between the methods of single-kidney GFR measurements was 0.38 ± 5.57 mL/min (p = 0.471); the regression line is identical to the diagonal (intercept = 0 and slope = 1) (p = 0.727 and p = 0.473, respectively), with a standard deviation of residuals of 5.56 mL/min.
Conclusion
A convenient and rapid single-kidney CT-GFR technique was presented and validated in this investigation.
Key Points
• The new CT-GFR method takes about 2.5 min of patient time.
• The CT-GFR method demonstrated identical results to the Gates-GFR method.
• The CT-GFR method is based on the fractional renal accumulation of iodinated CM.
• The CT-GFR method is achieved without additional radiation dose to the patient.
Similar content being viewed by others
Abbreviations
- CM:
-
Contrast material
- CMk :
-
Amount of CM accumulated in the kidney (in units of mgI)
- CMtotal :
-
Total amount of CM injected (in units of mgI)
- CT-GFR:
-
GFR determined by the CT method
- F :
-
Conversion factor between iodine concentration and CT number enhancement
- FRA:
-
Fractional renal accumulation = CMk/CMtotal
- Gates-GFR:
-
GFR determined by the Gates method
- GFR:
-
Glomerular filtration rate
- 99mTc-DTPA:
-
99mTc diethylenetriaminepentaacetic acid
References
Gates GF (1982) Glomerular filtration rate:estimation from fractional renal accumulation of 99mTc-DTPA (stannous). Am J Roentgenol 138:565–570
You S, Ma X, Zhang C et al (2017) Determination of single-kidney glomerular filtration rate (GFR) with CT urography versus renal dynamic imaging Gates method. Eur Radiol. https://doi.org/10.1007/s00330-017-5061-z
Becker J, Babb J, Serrano M (2013) Glomerular filtration rate in evaluation of the effect of iodinated contrast media on renal function. Am J Roentgenol 200:822–826
Hackstein N, Wiegand C, Langheinrich AC et al (2003) Measurement of glomerular filtration rate by low-dose iopromide plasma clearance. Acta Radiol 44:162–165
Wang L, Liu B, Wu XW et al (2012) Correlation between CT attenuation value and iodine concentration in vitro: discrepancy between gemstone spectral imaging on single-source dual-energy CT and traditional polychromatic X-ray imaging. J Med Imaging Radiat Oncol 56:379–383
Boone J, Strauss K, Cody D et al (2011) Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations. Report of AAPM Task Group 204. American Association of Physicists in Medicine, College Park
Frennby B, Almen T (2001) Use of spiral CT and the contrast medium iohexol to determine in one session aortorenal morphology and the relative glomerular filtration rate of each kidney. Eur Radiol 11:2270–2277
Lewis M, Goh V, Beggs S et al (2014) Quality control within the multicentre perfusion CT study of primary colorectal cancer (PROSPeCT): results of an iodine density phantom study. Eur Radiol 24:2309–2318
Kok M, Mihl C, Hendriks BM et al (2016) Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients. Eur J Radiol 85:1068–1074
Yuan X, Zhang J, Quan C et al (2016) A simplified whole-organ CT perfusion technique with biphasic acquisition: preliminary investigation of accuracy and protocol feasibility in kidneys. Radiology 279:254–261
Daghini E, Juillard L, Haas JA et al (2007) Comparison of mathematic models for assessment of glomerular filtration rate with electron-beam CT in pigs. Radiology 242:417–424
Kwon SH, Saad A, Herrmann SM et al (2015) Determination of single-kidney glomerular filtration rate in human subjects by using CT. Radiology 276:490–498
Krier JD, Ritman EL, Bajzer Z et al (2001) Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function. Am J Physiol Ren Physiol 281:F630–F638
Patlak CS, Blasberg RG (1985) Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations. J Cereb Blood Flow Metab 5:584–590
Helck A, Sommer WH, Klotz E et al (2010) Determination of glomerular filtration rate using dynamic CT-angiography: simultaneous acquisition of morphological and functional information. Investig Radiol 45:387–392
Helck A, Wessely M, Notohamiprodjo M et al (2013) CT perfusion technique for assessment of early kidney allograft dysfunction: preliminary results. Eur Radiol 23:2475–2481
Yuan X, Zhang J, Tang K et al (2017) Determination of glomerular filtration rate with CT measurement of renal clearance of iodinated contrast material versus 99mTc-DTPA dynamic imaging "Gates" method: a validation study in asymmetrical renal disease. Radiology 282:552–560
De Santo NG, Anastasio P et al (1999) Measurement of glomerular filtration rate by the 99mTc-DTPA renogram is less precise than measured and predicted creatinine clearance. Nephron 81:136–140
Ma YC, Zuo L, Zhang CL et al (2007) Comparison of 99mTc-DTPA renal dynamic imaging with modified MDRD equation for glomerular filtration rate estimation in Chinese patients in different stages of chronic kidney disease. Nephrol Dial Transplant 22:417–423
Inoue Y, Yoshikawa K, Suzuki T et al (2000) Attenuation correction in evaluating renal function in children and adults by a camera-based method. J Nucl Med 41:823–829
Takaki Y, Kojima A, Tsuji A et al (1993) Quantification of renal uptake of technetium-99m-DTPA using planar scintigraphy: a technique that considers organ volume. J Nucl Med 34:1184–1189
Acknowledgements
We thank Mr. Kolo from Toshiba Medical Systems Corporation for English language editing.
Funding
This study has received funding by National Natural Science Foundation of China (NO.81671680, NO.81570679, and NO.81200547) and Beijing NOVA program (NO.Z161100004916141)
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Guarantor
The scientific guarantor of this publication is Yuan XiaoDong.
Conflict of interest
The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.
Statistics and biometry
One of the authors (Yuan XiaoDong) has significant statistical expertise.
Ethical approval
Institutional review board approval was obtained.
Informed consent
Written informed consent was obtained from all subjects (patients) in this study.
Methodology
• prospective
• observational
• performed at one institution
Electronic supplementary material
ESM 1
(DOCX 70 kb)
Rights and permissions
About this article
Cite this article
Yuan, X., Tang, W., Shi, W. et al. Determination of glomerular filtration rate (GFR) from fractional renal accumulation of iodinated contrast material: a convenient and rapid single-kidney CT-GFR technique. Eur Radiol 28, 2763–2771 (2018). https://doi.org/10.1007/s00330-017-5289-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-017-5289-7