Skip to main content

Advertisement

Log in

The imaging of myocardial perfusion with 81mKr during coronary arteriography

  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

The use of 81mKr was investigated for imaging myocardial perfusion during coronary arteriography using conventional catheters. When the significance of stenosis judged by arteriography is unclear, the effect on tissue perfusion can be established and the contribution to collateral flow by each artery separately evaluated. The distribution of 81mKr, due to its 13-s half-life, represents regional blood flow. In order to evaluate interventions, studies can be repeated at a low radiation risk to patients. A sterile pyrogenfree 81Rb−81Kr generator was developed. With slow infusion, inadequate mixing and streaming takes place due to laminar flow in coronary arteries. Fast intermittent 3-ml 81Kr-dextrose bolus injections convincingly eliminated streaming artefacts. Imaging was performed in 13 patients with a mobile scintillation camera and digital imaging system. Blood flow was calculated using the inert gas washout technique. There was good correlation (r=0.91) between coronary blood flow determinations using 81mKr and 133Xe respectively. The perfusion images correlated well with the coronary angiograms. Total coronary arterial occlusions as demonstrated by arteriography were all shown as perfusion defects during rest. During atrial pacing myocardial flow was increased two-fold in normal coronary arteries and to a lesser extent in arteries with significant disease. The most critical lesion in a branch of a left coronary artery leads to a redistribution of perfusion during pacing.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Columbetti LG, Mayron LW, Kaplan E, Barnes WE, Friedman AM, Gindler JE (1974) Continuous radionuclide generation. Production and evaluation of a Krypton-81m mini-generator. JNM 15:868–873

    Google Scholar 

  • De Valois JC, Smith J, Pepperkamp TPR (1970) A computer programme for the determination of cerebral blood flow using the Kr-85 or Xe-133 intraarterial injection method. Biomed Comp 1:49–53

    Google Scholar 

  • Gould KL (1978) Assessment of coronary stenosis with myocardial perfusion imaging during pharmacologic vasodilation. Am J Cardiol 41:761–768

    Google Scholar 

  • Judkins MP (1968) Percutaneous transfemoral selective coronary arteriography. Radiol Clin N Am VI:3

    Google Scholar 

  • Kaplan E, Mayron LW, Friedman AM, Gindler JE, Frazin L, Moran JM, Loeb H, Gunnar RM (1976) Definition of myocardial perfusion by continuous infusion of Kr-81m. Am J Cardiol 37:878–884

    Google Scholar 

  • Kaplan E, Mayron LW (1976) Evaluation of perfusion with the 81Rb−81mKr generator. Semin Nucl Med 6:163–192

    Google Scholar 

  • Maseri A (1976) Radio-active tracer technique for evaluating coronary flow, chap 5. Yu PW, Goodwin JF, Klocke FJ (ed) Progress in Cardiology, Vol. 5, Lea and Fegiber, Philadelphia, p 145

    Google Scholar 

  • Maseri A, L'Abbata A, Michelalasai C, Pesola A, Pisani P, Marzilli M, Des Nes M, Mancini P (1977) Possibilities, limitations and techniques for study of regional myocardial perfusion in man by Xe-133. Cardiovasc Res 11:277–290

    Google Scholar 

  • Ritchie JL, Hamilton GW, Gould KL, Alle D, Kennedy JW, Hammermeister KE (1975) Myocardial imaging with Indium-111m and Technetium-99m macroaggregated albumin. Am J Cardiol 35:380–389

    Google Scholar 

  • Selwyn AP, Steiner R, Kivisaari A, Fox K, Forse G (1979a) Krypton-81 m in the physiological assessment of coronary arterial stenosis in man. Am J Cardiol 43:547–553

    Google Scholar 

  • Selwyn AP, Jones T, Turner JH, Pratt T, Clark J, Lavender P (1979b) Continuous assessment of regional myocardial perfusion in dogs using Krypton-81m. Circ Res 42:771–777

    Google Scholar 

  • Selwyn AP, Welman E, Fox K, Horlock P, Pratt T, Klein M (1979c) The effects of Nifedipine on acute experimental myocardial ischemia and infarction in dogs. Circ Res 44:16–23

    Google Scholar 

  • Van Zyl WH, Kleynhans PHT, Lötter MG, Ungerer MJ, Van Aswegen A, Minnaar PC, Weich DJV, Iturralde M (1979) A Krypton-81m generator for organ ventilation and perfusion investigations. S Afr Med J 55:920–924

    Google Scholar 

  • Wolf GL, Shaw DD, Baltaxe HA (1978) A proposed mechanism for transient increases in arterial pressure and flow during angiographic injections. Invest Radiol 13:195–199

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kleynhans, P.H.T., Lötter, M.G., van Aswegen, A. et al. The imaging of myocardial perfusion with 81mKr during coronary arteriography. Eur J Nucl Med 7, 405–409 (1982). https://doi.org/10.1007/BF00256819

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00256819

Keywords

Navigation