Abstract

Fluorescence microphotolysis — widely employed for diffusion studies — can be used to measure transfer (flux) of fluorescent solutes through membranes in single cells and organelles. This article analyses the methodological basis of flux measurements, provides experimental tests, and discusses potential applications. The principle of the method is to equilibrate cells, organelles or vesicles with a fluorescent solute, to deplete the interior of individual cells etc. of fluorescene by the pulse of a high-intensity microbeam, and to monitor influx of solute by microfluorometry. Simple equations are given and a computer curve fitting program is described by which rate constants of influx and membrane permeability coefficients can be derived from fluorescence measurements. The permeability of individual “leaky” human erythrocyte ghosts to fluorescein-isothiocyanate-labelled bovine serum albumin has been measured under various conditions. Multiple exposure to the high-intensity microbeam had no effect on permeability within experimental error. Flux measurements have been also performed on individual vesicles of 1–2 μm radius which had been derived from ghosts. The potential application of the method to sub-lightmicroscopic vesicles and to organelles within living cells is discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

FITC-BSA:

fluorescein isothiocyanate-labeled bovine serum albumin

References

  • Axelrod D (1977) Cell surface heating during fluorescence photobleaching recovery experiments. Biophys J 18:129–131

    Google Scholar 

  • Axelrod D (1983) Lateral motion of membrane proteins and biological function. J Membr Biol 75:1–10

    Google Scholar 

  • Axelrod D, Koppel DE, Schlessinger J, Elson E, Webb WW (1976) Mobility measurements by analysis of fluorescence photobleaching recovery experiments. Biophys J 16:1055–1069

    Google Scholar 

  • Cherry RJ (1979) Rotational and lateral diffusion of membrane proteins. Biochim Biophys Acta 559:289–327

    Google Scholar 

  • Christensen HN (1975) Biological transport. Benjamin, Reading

    Google Scholar 

  • Davoust J, Devaux PF, Leger L (1982) Fringe pattern photobleaching, a new method for the measurement of transport coefficients of biological macromolecules. EMBO J 1:1233–1238

    Google Scholar 

  • Dodge JT, Mitchell C, Hanahan, DJ (1963) The preparation and chemical characterization of hemoglobin-free ghosts of human erythrocytes. Arch Biochem Biophys 100:119–130

    CAS  PubMed  Google Scholar 

  • Edidin M, Zagyanski Y, Lardner TJ (1976) Measurement of membrane lateral diffusion in single cells. Science 191:466–468

    Google Scholar 

  • Eidelman O, Cabantchik ZI (1980) A method for measuring anion transfer across red cell membranes by continuous monitoring of fluorescence. Anal Biochem 106:335–341

    Google Scholar 

  • Fenichel RI, Horowitz SB (1969) Intracellular transport. In: Dowben RM (ed) Biological membranes. Little, Brown and Company, Boston, pp 177–221

    Google Scholar 

  • Halestrap AP, McGivan JD (1979) Measurement of membrane transport phenomena. Tech Metabol Res B206:1–23

    Google Scholar 

  • Jacobson K, Wu E, Poste G (1976) Measurement of the translational mobility of concanavalin A in glycerol-saline solutions and on the cell surface by fluorescence recovery after photobleaching. Biochim Biophys Acta 43:215–222

    Google Scholar 

  • Jacobson K, Hou Y, Wojcienszyn J (1978) Evidence for lack of damage during photobleaching measurements of lateral mobility of cell surface components. Exp Cell Res 116:179–189

    Google Scholar 

  • Johnson P, Garland PB (1981) Depolarization of fluorescence depletion. A microscopic method for measuring rotational diffusion of membrane proteins on the surface of a single cell. FEBS Lett 132:252–256

    Google Scholar 

  • Kansu E, Ersler AJ (1980) The red cell. In: Seligson D (ed) Clinical laboratory science, vol 2. CRC Press, Boca Raton, Sect 1, pp 123–142

    Google Scholar 

  • Kohen E, Siebert G, Kohen C (1971) Transfer of metabolites across the nuclear membrane, Hoppe-Seyler's. Z Physiol Chem 352:927–937

    Google Scholar 

  • Koppel DE (1979) Fluorescence redistribution after photobleaching: a new multipoint analysis of membrane translational dynamics. Biophys J 28:281–292

    Google Scholar 

  • Koppel DE (1983) Fluorescence photobleaching as a probe of translational and rotational motions. In: Sha'afi RI, Fernandez SM (eds) Fast methods in physical biochemistry. Elsevier, Amsterdam New York Oxford, pp 339–367

    Google Scholar 

  • Koppel DE, Axelrod D, Schlessinger J, Elson EL, Webb WW (1976) Dynamics of fluorescence marker concentration as a probe of mobility. Biophys J 16:1315–1329

    Google Scholar 

  • Kotyk A, Janáçek K (1970) Cell membrane transport. Plenum Press, New York London

    Google Scholar 

  • Lanni F, Ware BR (1982) Modulation detection of fluorescence photobleaching recovery. Rev Sci Instrum 53:905–908

    Google Scholar 

  • Lieber MR, Steck TL (1982) A description of the holes in human erythrocyte membrane ghosts. J Biol Chem 257:11651–11659

    Google Scholar 

  • Nigg EA, Kessler M, Cherry RJ (1979) Labeling of human erythrocyte membranes with eosin probes used for protein diffusion measurements: inhibition of anion transport and photooxidative inactivation of acetylcholinesterase. Biochim Biophys Acta 550:328–340

    Google Scholar 

  • Paine PL, Horowitz SB (1980) The movement of material between nucleus and cytoplasm. In: Goldstein L, Prescott DM (eds) Cell biology, vol 4. Academic Press, New York, pp 299–341

    Google Scholar 

  • Parker CA (1968) Photoluminescence in solution. Elsevier, Amsterdam London New York

    Google Scholar 

  • Pfaff E, Klingenberg M (1968) Adenine nucleotide translocation of mitochondria. Eur J Biochem 6:66–79

    Google Scholar 

  • Peters R (1981) Translational diffusion in the plasma membrane of single cells as studied by fluorescence microphotolysis. Cell Biol Int Rep 5:733–760

    Google Scholar 

  • Peters R (1983a) Fluorescence microphotolysis. Diffusion measurements in single cells. Naturwissenschaften 70:294–302

    Google Scholar 

  • Peters R (1983b) Nuclear envelope permeability measured by fluorescence microphotolysis of single liver cell nuclei. J Biol Chem 258:11427–11429

    Google Scholar 

  • Peters R (1984) Nucleo-cytoplasmic flux and intracellular mobility in single hepatocytes measured by fluorescence microphotolysis. EMBO J (in press)

  • Peters R, Richter HP (1981) Translational diffusion in the plasma membrane of sea urchin eggs. Dev Biol 86:285–293

    Google Scholar 

  • Peters R, Peters J, Tews KH, Bähr W (1974) A microfluorimetric study of translational diffusion in erythrocyte membranes Biochim Biophys Acta 367:282–294

    Google Scholar 

  • Peters R, Brünger A, Schulten K (1981) Continuous fluorescence microphotolysis: A sensitive method for the study of translational diffusion in single cells. Proc Natl Acad Sci USA 778:962–966

    Google Scholar 

  • Schulz SG (1980) Basic principles of membrane transport. Cambridge University Press, Cambridge London New York Melbourne Sydney

    Google Scholar 

  • Sheetz MP, Koppel DE (1979) Membrane damage caused by irradiation of fluorescent concanavalin A. Proc Natl Acad Sci USA 76:3314–3317

    Google Scholar 

  • Sims PJ, Waggoner AS, Wang CH, Hoffman JF (1974) Studies on the mechanism by which cyanine dyes measure membrane potential in red blood cells and phosphatidylcholine vesicles. Biochemistry 13:3315–3330

    Google Scholar 

  • Smith BA, McConnell HM (1978) Determination of molecular motion in membranes using periodic pattern photobleaching. Proc Natl Acad Sci USA 75:2759–2763

    Google Scholar 

  • Smith LM, Weis RM, McConnell HM (1981) Measurement of rotational diffusion of membrane components by fluorescence photobleaching. Biophys J 36:73–91

    Google Scholar 

  • Sten-Knudsen O (1978) Passive transport processes. In: Giebisch G, Tosteson DC, Ussing HH (eds) Membrane transport in biology, vol 4. Springer Verlag, Berlin Heidelberg New York, p 5113

    Google Scholar 

  • Tanner JE (1983) Intracellular diffusion of water. Arch Biochem Biophys 224:416–428

    Google Scholar 

  • Thompson NL, Burghardt TP, Axelrod D (1981) Measuring surface dynamics of biomolecules by total internal reflection fluorescence with photobleaching recovery or correlation spectroscopy. Biophys J 33:435–454

    Google Scholar 

  • Vaz WLC, Derzko ZI, Jacobson KA (1982) Photobleaching measurements of the lateral diffusion of lipids and proteins in artificial phospholipid bilayer membranes. In: Poste G, Nicolson GL (eds) Membrane reconstitution. Elsevier, Amsterdam New York Oxford, pp 83–136

    Google Scholar 

  • Wohlhueter RM, Marz R, Graff JC, Plagemann PWG (1978) A rapid-mixing technique to measure transport in suspended animal cells: Applications to nucleoside transport in Novikoff rat hepatoma cells. Methods Cell Biol 20:211–236

    Google Scholar 

  • Wolf DE, Edidin M, Dragsten PR (1980) Effect of bleaching light on measurements of lateral diffusion in cell membranes by the fluorescence photobleaching recovery method. Proc Natl Acad Sci USA 77:2043–2045

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Peters, R. Flux measurement in single cells by fluorescence microphotolysis. Eur Biophys J 11, 43–50 (1984). https://doi.org/10.1007/BF00253857

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00253857

Key words

Navigation