Abstract
A new preparation of 111In DTPA for intrathecal administration has been tested and found to be a safe and highly efficacious cisternographic agent. The rate of removal of 111In DTPA from the C.S.F. and from the whole body has been measured and has been found to be of no diagnostic value in the distinction between patients with cerebral atrophy and those with normotensive hydrocephalus. Longterm retention studies show no evidence of significant long-term retention of indium in the C.S.F. The absorbed radiation dose has been investigated and found to be in good agreement with previous estimates based upon extrapolated data.
Similar content being viewed by others
References
Anderson, P.O., Siegel, B.A.: Adverse reactions following DTPA 111In cisternography. J. Nucl. Med. 14, 609 (1973)
Askienazy, S., Lumbroso, J., Moreau, R., Hirch, J.F., Pierre-Kahn, A.: Value of 111In DTPA cisternography with biological half-life determination in operative indications and surveillance of ventriculo-cisternotomy. Eur. J. Nucl. Med. 2, 104 (1977)
Benson, D.F., LeMay, M., Patten, D.H., Rubens, A.B.: Diagnosis of normal pressure hydrocephalus. New Eng. J. Med. 283, 609 (1970)
Brookeman, V.A., Morin, R.L.: Dosimetry of several DTPA radiopharmaceuticals in cisternography. J. Nucl. Med. 16, 1177 (1975)
Cooper, J., Levin, J., Wagner, H.: Quantitative comparison of in vitro and in vivo method for the detection of endotoxin. J. Lab. Clin. Med. 78, 138 (1971)
Cooper, J.F., Harbert, J.C.: Endotoxin as a cause of aseptic memingitis after radionuclide cisternography. J. Nucl. Med. 16, 809 (1975)
Goodwin, D.A., Chun Hun Song, B.S., Finston, R., Malin, P.: Preparation, physiology and dosimetry of 111In-labelled radiopharmaceuticals for cisternography. Radiology 108, 91 (1973)
McKusick, K.A., Malmud, L.S., Kordella, P.A., Wagner, H.N.: Radionuclide cisternography. Normal values for nasal secretion of intrathecally injected 111 In DTPA. J. Nucl. Med. 14, 933 (1973)
Merrick, M.V., Gunasekera, S.W., Lavender, J.P., Nunn, A.D., Thakur, M.L., Williams, J.P.: The use of Indium-111 for tumour localisation. Medical Radioisotope Scintigraphy. 2, 721. Vienna: I.A.E.A. 1973
Rojas-Corona, R.R., Skarnes, R., Takuma, S., Fine, J.: The Limulus coagulation test for endotoxin, a comparison with other assay methods. Proc. Soc. Exp. Biol. Med. 132, 599 (1964)
Shani, J., Atkins, H.L., Wolf, W.: Adverse reactions to radiopharmaceuticals. Sem. Nucl. Med. 6, 305 (1976)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Merrick, M.V., Simpson, J.D. & Ferrington, C. Measurement of 111In DTPA clearance during radionuclide cisternography. Eur J Nucl Med 3, 105–108 (1978). https://doi.org/10.1007/BF00251633
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/BF00251633