Abstract
We have compared haemodynamic effects of venous gas emboli during continuous air infusion into the right atrium and after rapid decompression in pigs. Eight anaesthetized and spontaneously breathing pigs received continuous air infusion at a rate of either 0.05 ml·kg−1 · min−1 (six pigs, air infusion group) or 0.10 ml·kg−1 · min−1 (two pigs). Another eight pigs (decompression group) underwent a 30-min compression to 5 bar (500 kPa, absolute pressure), followed by a rapid decompression (2 bar·min−1). Haemodynamic variables were measured or calculated, and bubbles in the pulmonary artery were monitored using transoesophageal echocardiography. The results showed less variation in the maximal increase in mean pulmonary arterial pressure (\({BP}\) a, pulm) during air infusion (0.05 ml·kg−1 · min−1) than after decompression, although the mean maximal increase did not differ between the two groups [28.0 mmHg (3.73 kPa), 95% confidence interval (CI) 23.5–32.5, vs 32.0 mmHg (4.27 kPa), 95% CI 25.3-38.7, P=0.3]. The \({BP}\) a,pulm stabilized or decreased very slowly after peak values were reached in the air infusion group, whereas the \({BP}\) a,pulm decreased rapidly during the same period in the decompression group. No significant changes in mean arterial pressure were observed during air infusion (0.05 ml· kg−1 · min−1), in contrast to the rapid increase and the subsequent decrease, that appeared after decompression. Finally, the maximal bubble count was much lower in the air infusion group than in most of the pigs in the decompression group. The two pigs that received 0.10 ml·kg−1 · min−1 stopped breathing after 5-min infusion, developed arterial hypotension and died.
Similar content being viewed by others
References
Adornato DC, Gildenberg PL, Ferrario CM, Smart J, Frost EAM (1978) Pathophysiology of intravenous air embolism in dogs. Anesthesiology 49:120–127
Albertine KH, Wiener-Kronish JP, Koike K, Staub NC (1984) Quantification of damage by air emboli to lung microvessels in anesthetized sheep. J Appl Physiol 57:1360–1368
Atkins CE, Lehner CE, Beck KA, Dubielzig RR, Nordheim EV, Lanphier EH (1988) Experimental respiratory decompression sickness in sheep. J Appl Physiol 65:1163–1171
Berglund E, Josephson S (1970) Pulmonary air embolization in the dog. I. Hemodynamic changes on repeated embolizations. Scand J Clin Lab Invest 26:97–103
Bove AA, Hallenbeck JM, Elliott DH (1974) Circulatory responses to venous air embolism and decompression sickness in dogs Undersea Biomed Res 1:207–220
Butler BD, Hills BA (1979) The lung as a filter for microbubbles. J Appl Physiol 47:537–543
Butler BD, Hills BA (1981) Effect of excessive oxygen upon the capability of the lungs to filter gas emboli. In: Bachrach AJ, Matzen MM (eds) Underwater physiology VII. Undersea Medical Society, Bethesda, Md., pp 95–102
Butler BD, Hills BA (1985) Transpulmonary passage of venous air emboli. J Appl Physiol 59:543–547
Catron PW, Thomas LB, Flynn ET, McDermott JJ, Holt MA (1987a) Effects of He-O2 breathing during experimental decompression sickness following air dives. Undersea Biomed Res 14:101–111
Catron PW, Thomas LB, McDermott JJ, Smallridge RC, Lake CR, Kinzer C, Chernow B, Flynn ET (1987b) Hormonal changes during decompression sickness. Undersea Biomed Res 14:331–341
Christman CL, Catron PW, Flynn ET, Weathersby PK (1986) In vivo microbubble detection in decompression sickness using a second harmonic resonant bubble detector. Undersea Biomed Res 13:1–18
Dalen JE, Haynes FW, Hoppin FG, Evans GL, Bhardwaj P, Dexter L (1967) Cardiovascular responses to experimental pulmonary embolism. Am J Cardiol 20:3–9
Edmonds C, Lowry C, Pennefather J (1992) Dividing and subaquatic medicine. 3rd edn. Butterworth-Heinemann, Oxford, pp 152
Eftedal O, Brubakk AO (1993) Detecting intravascular gas bubbles in ultrasonic images. Med Biol Eng Comput (in press)
Guyton AC, Jones CE, Coleman TG (1973) Measurement of cardiac output by the direct Fick method. In: Circulatory physiology: cardiac output and its regulation. 2nd edn. Saunders, Philadelphia, pp 21–39
Hills BA (1974) Air embolism: fission of microbubbles upon collision in plasma. Clin Sci Mol Med 46:629–634
Hills BA, Butler BD (1981) Size distribution of intravascular air emboli produced by decompression. Undersea Biomed Res 8:163–170
Hlastala MP, Robertson HT, Ross BK (1979) Gas exchange abnormalities produced by venous gas emboli. Respir Physiol 36:1–17
Malik AB (1983) Pulmonary microembolism. Physiol Rev 63:1114–1207
Mandelbaum I, King H (1963) Pulmonary air embolism. Surg Forum 14:236–238
Matjasko J, Petrozza P, Cohen M, Steinberg P (1985) Anesthesia and surgery in the seated position: analysis of 554 cases. Neurosurgery 17:695–702
Matthews JNS, Altman DG, Campbell MJ, Royston P (1990) Analysis of serial measurements in medical research. BMJ 300:230–235
McGrath BJ, Zimmerman JE, Williams JF, Parmet J (1989) Carbon dioxide embolism treated with hyperbaric oxygen. Can J Anaesth 36:586–589
Neuman TS, Spragg RG, Wagner PD, Moser KM (1980) Cardiopulmonary consequences of decompression stress. Respir Physiol 41:143–153
Orebaugh SL (1992) Venous air embolism: clinical and experimental considerations. Crit Care Med 20:1169–1177
Powell MR, Spencer MP, von Ramm O (1982) Ultrasonic surveillance of decompression. In: Bennett PB, Elliott DH (eds) The physiology and medicine of diving, 3rd edn. Bailliere Tindall, London, pp 404–434
Sergysels R, Jasper N, Delaunois L, Chang HK, Martin RR (1978) Effect of ventilation with different gas mixtures on experimental lung air embolism. Respir Physiol 34:329–343
Shirai M, Sada K, Ninomiya I (1988) Diameter and flow velocity changes in small pulmonary vessels due to microembolization. J Appl Physiol 65:288–296
Spencer MP, Oyama Y (1971) Pulmonary capacity for dissipation of venous gas emboli. Aerosp Med 42:822–827
Verstappen FTJ, Bernards JA, Kreuzer F (1977) Effects of pulmonary gas embolism on circulation and respiration in the dog. I. Effects on circulation. Pflügers Arch 368:89–96
Vik A, Brubakk AO, Hennessy TR, Jenssen BM, Ekker M, Slørdahl SA (1990) Venous air embolism in swine: transport of gas bubbles through the pulmonary circulation. J Appl Physiol 69:237–244
Vik A, Jenssen BM, Brubakk AO (1991) Effect of aminophylline on transpulmonary passage of venous air emboli in pigs. J Appl Physiol 71:1780–1786
Vik A, Jenssen BM, Eftedal O, Brubakk AO (1993) Relationship between venous bubbles and hemodynamic responses after decompression in pigs. Undersea & Hyperbaric Med 20:233–248
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Vik, A., Munro Jenssen, B. & Brubakk, AO. Comparison of haemodynamic effects during venous air infusion and after decompression in pigs. Europ. J. Appl. Physiol. 68, 127–133 (1994). https://doi.org/10.1007/BF00244025
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00244025