Improved positron emission tomography quantification by Fourier-based restoration filtering

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Positron emission tomography (PET) images are characterized by both poor spatial resolution and high statistical noise. Conventional methods to reduce noise, such as local weighted averaging, produce further deteriorations in spatial resolution, while the use of deconvolution to recover resolution typically amplifies noise to unacceptable levels. We studied the use of two-dimensional Fourier filtering to simultaneously increase quantitative recovery and reduce noise. The filter was based on inversion of the scanner's measured transfer function, coupled with high frequency roll-off. In phantom studies, we found improvements in both “hot” and “cold” sphere quantification. Compared with ramp-only filtering, improvements in hot spot recovery for the highest accuracy filter averaged 13.6%±6.6% for spheres larger than 15 mm; improvements in cold spot recovery averaged 30.7%±4.7%. At the same time, the noise was reduced by a factor of 3 compared with ramponly filtering. Fourier-based image restoration filtering is thus capable of improving both accuracy and precision in PET.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bergstrom M, Eriksson L, Bohm C, Blomqvist G, Litton J (1983) Correction for scattered radiation in a ring detector positron camera by integral transformation of the projection. J Comput Assist Tomogr 7:42–50

    Google Scholar 

  • Budinger TF, Derenzo SE, Greenberg WL, Gullberg GT, Huesman RH (1978) Quantitative potentials of dynamic emission computed tomography. J Nucl Med 19:309–315

    Google Scholar 

  • Derenzo SE (1986) Mathematical removal of positron range blurring in high resolution tomography. IEEE Trans Nucl Sci 33:565–569

    Google Scholar 

  • Gilland DR, Tsui BMW, McCartney WH, Perry JR, Berg J (1988) Determination of the optimum filter function for SPECT imaging. J Nucl Med 29:643–650

    Google Scholar 

  • Goris ML, Briandet PA (1983) A clinical and mathematical introduction to computer processing of scintigraphic images. Raven, New York

    Google Scholar 

  • Hoffman EJ, Phleps ME, Huang SC (1983) Performance evaluation of a positron tomograph designed for brain imaging. J Nucl Med 24:245–257

    Google Scholar 

  • Karp JS, Daube-Witherspoon ME, Hoffman EF et al. (1991) Performance standards in positron emission tomography. J Nucl Med 32:2342–2350

    Google Scholar 

  • Kessler RM, Ellis JR, Eden M (1984) Analysis of emission tomographic scan data: limitations imposed by resolution and background. J Comput Assist Tomogr 8:514–522

    Google Scholar 

  • King MA, Doherty PW, Schwinger RB, Jacobs DA, Kidder RE, Miller TR (1983a) Fast count-dependent digital filtering of nuclear medicine images. J Nucl Med 24:1039–1045

    Google Scholar 

  • King MA, Doherty PW, Schwinger RB (1983b) A Wiener filter for nuclear medicine images. Med Phys 10:876–880

    Google Scholar 

  • King MA, Schwinger RB, Doherty PW, Penney BC (1984) Two-dimensional filtering of SPECT images using the Metz and Wiener filters. J Nucl Med 25:1234–1240

    Google Scholar 

  • King MA, Schwinger RB, Penney BC, Doherty PW, Bianco JA (1986) Digital restoration of indium-111 and iodine-123 SPECT images with optimized Metz filters. J Nucl Med 27:1327–1336

    Google Scholar 

  • King MA, Glick SJ, Penney BC, Schwinger RB, Doherty PW (1987) Interactive visual optimization of SPECT prereconstruction filtering. J Nucl Med 28:1192–1198

    Google Scholar 

  • Links JM, Jeremy RW, Dyer SM, Frank TL, Becker LC (1990a) Wiener filtering improves quantification of regional myocardial perfusion with thallium-201 SPECT. J Nucl Med 31:1230–1236

    Google Scholar 

  • Links JM, Loats HL, Loats PE, Casey M, Nutt R, Wagner HN (1990b) Simultaneous resolution recovery and noise reduction in positron tomography by Fourier filtering of 2-d projection data abstract. J Nucl Med 31:862–863

    Google Scholar 

  • Madsen MT, Park CH (1985) Enhancement of SPECT images by Fourier filtering the projection image set. J Nucl Med 26:395–402

    Google Scholar 

  • Miller TR, Goldman KJ, Epstein DM, Biello DR, Sampathkumaran KS, Kumar B, Siegel BA (1984) Improved interpretation of gated cardiac images by use of digital filters. Radiology 152:795–800

    Google Scholar 

  • Penney BC, Glick SJ, King MA (1990) Relative importance of the error sources in Wiener restoration of scintigramms. IEEE Trans Med Imag 9:60–70

    Google Scholar 

  • Todd-Pokropek A (1980) Image processing in nuclear medicine. IEEE Tran Nucl Sci NS-27:1080–1094

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Correspondence to: J.M. Links

Rights and permissions

Reprints and permissions

About this article

Cite this article

Links, J.M., Leal, J.P., Mueller-Gaertner, H.W. et al. Improved positron emission tomography quantification by Fourier-based restoration filtering. Eur J Nucl Med 19, 925–932 (1992). https://doi.org/10.1007/BF00175857

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00175857

Key words

Navigation