Summary

Using a quadrupole mass spectrometer (QMS), we continuously monitored N2, O2, CO2, and ethanol in the outlet gas of a batch fermentor. A computer was used to control the QMS, perform correction calculations and account for interferences between some ion peaks. The ability to continously scan multiple peaks and to use N2 as an internal standard provided rapid and accurate monitoring of fermentation performance. Over the range of interest, a linear response was obtained for all the compounds measured by the QMS.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Churchill, S.W. (1974). The interpretation and use of rate data. In: The Rate Concept, p. 510, Scripta Publishing Co: Washington D.C.

    Google Scholar 

  • Delpy, D.T. and Parker, D. (1975). Lancet, 3 May, 1016.

  • Eight Peak Index of Mass Spectra (1974). p. 1493, Mass Spectrometry Data Centre: Awre, U.K.

  • Maxon, W.D. and Johnson, M.J. (1953). Ind. Chem. Eng. 45, 2554–2560.

    Google Scholar 

  • Miller, G.L. (1959). Anal. Chem. 31, 426–428.

    Google Scholar 

  • Mieure, J.P., Mappes, G.W., Tucker, E.S. and Dietrich, M.W. (1976). Separation of trace organic compounds from water. In: Identification & Analysis of Organic Pollutants in Water, L.H. Keith, ed., pp. 113–133, Ann Arbor Science: Ann Arbor, MI.

    Google Scholar 

  • Muysers, K. and Smidt, V. (1972). Clinical uses of mass spectrometry. In: Biomedical Applications of Mass Spectrometry, G.R. Waller, ed., pp. 601–622. Wiley-Interscience: New York.

    Google Scholar 

  • Reuss, M., Piehl, H. and Wagner, F. (1975). Europe. J. Appl. Microbiol., 1, 323–325.

    Google Scholar 

  • Sodal, I. E. and Swanson, G.D. (1980). Mass spectrometer in patient monitoring. In: Essential Non-invasive Monitoring, J.S. Gravenstein, R.S. Newbower, A.K. Ream and N.T. Smith, eds., pp. 217–234, Grun and Stratton: New York.

    Google Scholar 

  • Wang, H.Y., Cooney, C.L. and Wang, D.I.C. (1977). Biotechnol. Bioeng. 19, 69–86.

    Google Scholar 

  • Weaver, J.C., Mason, M.K., Jarrell, J.A. and Peterson, J.W. (1976). Biochem. Biophis. Acta, 438, 296–303.

    Google Scholar 

  • Weaver, J.C. and Abrams, J.H. (1979). Rev. Sci. Inst. 50, 478–481.

    Google Scholar 

  • Weaver, J.C., Perley, C.R., Reames, F.M. and Cooney, C.L. (1980). Biotechnol. Lett., 2, 133–137.

    Google Scholar 

  • Westover, L.B., Tou, J.C. and Mark, J.H. (1974). Anal. Chem., 46, 568–571.

    Google Scholar 

  • Woldering, S., Owens, F. and Woolford, D.C. (1976). Science, 153, 885–887.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pungor, E., Perley, C.R., Cooney, C.L. et al. Continuous monitoring of fermentation outlet gas using a computer coupled MS. Biotechnol Lett 2, 409–414 (1980). https://doi.org/10.1007/BF00144246

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00144246

Keywords

Navigation