Stability of hydroxylapatite plasma-sprayed coated Ti−6AI−4V under cyclic bending in simulated physiological solutions

  • Papers
  • Published:
Journal of Materials Science: Materials in Medicine Aims and scope Submit manuscript

The aim of this research was to study the stability of plasma-sprayed eoated metal systems and to evaluate their susceptibility to the occurrence of corrosion fatigue. Hydroxylapatite plasma-sprayed coated samples of Ti−6AI−4V were studied under cyclic bending. During fatigue testing samples were immersed in a simulated physiological solution and mechanical and electrochemical degradation were monitored. Applied loads were intended to crack the ceramic coating and not the metal substrate. Electrochemical impedance spectroscopy was used to further characterize the electrochemical behaviour. No increase in tendency to corrode was detected in open-circuit corrosion fatigue testing. It appears as if the coating cracking does not increase metal substrate corrosion susceptibility. The coating integrity has been seriously affected, with marked decrease in thickness, due to the synergistic effect of load and presence of simulated body fluids environment. Impedance results, however, show a general tendency to an increase in corrosion kinetics after corrosion fatigue testing.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. K. Soballe, E. S. Hansen, H. B. Rasmussen, P. H. Jorgensen and C. Bunger, J. Orthop. Res. 10 (1992) 285.

    Google Scholar 

  2. S. D. Brown, Thin Solid Films 119 (1984) 127.

    Google Scholar 

  3. D. P. Rivero, J. Fox, A. K. Skipor, R. M. Urban and J. O. Galante, J. Biomed. Mater. Res. 22 (1988) 191.

    Google Scholar 

  4. M. Y. Shareef, P. F. Messer and Van R. Noort, Biomaterials 14 (1993) 69.

    Google Scholar 

  5. R. Y. Whitehead, L. C. Lucas and W. R. Lacefield, Clin. Mater. 12 (1993) 31.

    Google Scholar 

  6. H. Ji and P. M. Marquis, Biomaterials 14 (1993) 64.

    Google Scholar 

  7. C. A. Van Blitterswijk, J. J. Grote, W. Kuypers, C. J. G. Blok-Van Hoek and W. Th. Daems, Biomaterials 6 (1985) 243.

    Google Scholar 

  8. F. Kummer and W. Jaffe. J. Appl. Biomater., 3 (1992) 211.

    Google Scholar 

  9. H. S. DOBBS and J. L. M. ROBERTSON, in “Titanium alloys in surgical implants”, ASTM STP 796, edited by H. A. Luckey and F. Kubli Jr (ASTM, 1983) p. 277.

  10. M. A. IMAN, A. C. FRAKER and C. M. GILMORE, in “Corrosion and degradation of implant materials”, ASTM STP 684, edited by B. C. Syrett and A. Acharya (ASTM, 1979) p. 173.

  11. L. E. SLOTER and H. R. PIEHLER, in “Corrosion and degradation of implant materials”, ASTM STP 684, edited by B. C. Syrett and A. Acharya (ASTM, 1979) p. 195.

  12. M. Morita, T. Sasada, H. Hayashi and Y. Tsukamoto, J. Biomed. Mater. Res. 22 (1988) 529.

    Google Scholar 

  13. H. LIN, H. CU and K. dE GROOT, in Transactions of Fourth Biomaterials Congress, Berlin, April 1992, edited by U. Gross, p. 193.

  14. S. D. Cook, N. Thongpreda, R. C. Anderson and R. J. Haddad Jr, J. Biomed. Mater. Res. 22 (1988) 287.

    Google Scholar 

  15. R. L. Reis, F. J. Monteiro and A. Garrido, in “Bioceramies 5”, Kyoto, November 1992, edited by T. Yamamuro, T. Kokubu and T. Nakamura (Kobunshi Kankekai, Tokyo, 1992) p. 259.

    Google Scholar 

  16. E. A. Silva, M. A. Barbgsa, O. Conde, M. C. Belo and I. Sutherland, Clin. Mater. 7 (1991) 31.

    Google Scholar 

  17. M. A. Barbosa, in “Bioceramies 4”, London, September 1991, edited by W. Bonfield, F. W. Hastings and K. E. Janmer (Butterworth-Heinemann, London, 1991) p. 325.

    Google Scholar 

  18. D. C. Silverman, Corrosion 46 (1990) 589.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Reis, R.L., Monteiro, F.J. & Hastings, G.W. Stability of hydroxylapatite plasma-sprayed coated Ti−6AI−4V under cyclic bending in simulated physiological solutions. J Mater Sci: Mater Med 5, 457–462 (1994). https://doi.org/10.1007/BF00058983

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00058983

Keywords

Navigation