Screw-shaped implants with an outer diameter of 3.7 mm and a total length of 8 mm were made from rods of commercially pure titanium (c.p. Ti) and commercially pure zirconium (c.p. Zr). Prior to insertion in rabbit tibia for 12 weeks, the surface roughness of two randomly chosen c.p. Ti and two c.p. Zr machined implants of the batch were numerically and visually described with a TopScan 3-D system. Irrespective of implant material, they demonstrated rather similar surface roughnesses, for example, the R a and R q values (that describe the average deviation from the mean line) were 0.79 and 1.18 for c.p. Ti versus 0.56 and 0.86 for c.p. Zr. Each rabbit had four implants inserted; two made of c.p. Ti in one leg and two made of c.p. Zr in the other. The bone tissue reactions to the materials were qualitatively and quantitatively examined. Removal torque tests were performed on the distal implants and histomorphometrical evaluations of the proximal ones. No qualitative or quantitative bone differences were observed. Removal torque measurements demonstrated a mean of 26.2 N cm±9.6 for c.p. Ti versus a mean of 25.9 N cm±7.1 for the c.p.Zr implants. Histomorphometrical comparisons of the bone-to-metal contact revealed a mean of 29 ±10.2% for c.p. Ti and a mean of 19±5.5% for the c.p. Zr samples. The mean bone area in the threads around the c.p. Ti samples was 49±16.6% compared to 43±7.9% for the c.p. Zr group. Commercially pure titanium and zirconium implants seemed to be well accepted by the bone bed after 12 weeks of insertion in rabbit bone.
Similar content being viewed by others
References
J. GALANTE and W. ROSTOCKER, Clin. Orthop. Relat. Res. 86 (1972) 237.
A. WENNERBERG, T. ALBREKTSSON, H. ULRICH and J. J. KROL, J. Biomed. Eng. 14 (1992) 412.
H. DAGNALL, “Exploring surface texture”, 2nd Edn (Rank Taylor Hobson Limited, Leicester, England, 1986).
K. DONATH, Der Präparator 34 (1988) 197.
C. B. JOHANSSON. Thesis, Dept. of Handicap Research, University of Göteborg (1991).
T. ALBREKTSSON, H. A. HANSSON and B. IVARSSON, Biomaterials 6 (1985) 97.
M. NIKI, G. ITO, T. MATSUDA and M. OGINO, “The bone materials interface”, edited by J. E. Davies (University of Toronto Press, 1991) p. 350.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Johansson, C.B., Wennerberg, A. & Albrektsson, T. Quantitative comparison of screw-shaped commercially pure titanium and zirconium implants in rabbit tibia. J Mater Sci: Mater Med 5, 340–344 (1994). https://doi.org/10.1007/BF00058959
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00058959