Skip to main content

Advertisement

Log in

Corrosion of stainless steel sternal wire after long-term implantation

  • ORIGINAL ARTICLE
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

A variety of metallic components have been used in medical devices where lifelong durability and physical strength are demanded. To investigate the in vivo changes of implanted metallic medical devices in humans, stainless steel sternal wires removed from patients were evaluated. Stainless steel (316L) sternal wires removed from four patients after 10, 13, 22, and 30 years of implantation were evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). Macroscopically, the removed specimens maintained their metallic luster and color. Under SEM, small holes were observed sporadically at 10 years and they tended to connect in the drawing direction. The longer the implanted duration, the more numerous and deeper were the crevices observed. By EDS, sulfur, phosphorus, and calcium were identified in all areas at 10 years, in addition to the component elements of stainless steel, comprising iron, chromium, nickel, and manganese. Corrosion products observed at 30 years were identified as calcium phosphate. In conclusion, stainless steel sternal wires develop corroded pores that grow larger and deeper with time after implantation; however, the pores remain shallow even after decades of implantation and they may not be a cause of mechanical failure. An amount of metal ions equivalent to the corroded volume must have been released into the human body, but the effect of these metal ions on the body is not apparent.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. K Takazawa N Ishikawa H Miyagawa T Yamamoto A Hariya S Dohi (2003) ArticleTitleMetal allergy to stainless steel wire after coronary artery bypass grafting J Artif Organs 6 71–72 Occurrence Handle10.1007/s100470300011 Occurrence Handle14598128

    Article  PubMed  Google Scholar 

  2. PG Fine SV Karwande (1990) ArticleTitleSternal wire-induced persistent chest pain: a possible hypersensitivity reaction Ann Thorac Surg 49 135–136 Occurrence Handle1:STN:280:By%2BC38%2FntFI%3D Occurrence Handle2297262

    CAS  PubMed  Google Scholar 

  3. PM Gordon PK Buxton KM McLaren RD Aldridge (1996) ArticleTitleSensitivity to sternotomy wires may cause postoperative pruritus Ann Thorac Surg 61 1514–1516 Occurrence Handle10.1016/0003-4975(95)01126-9 Occurrence Handle1:STN:280:BymB3c7nslw%3D Occurrence Handle8633970

    Article  CAS  PubMed  Google Scholar 

  4. ME Northington CC Huang (2004) ArticleTitlePyogenic granuloma caused by exposed sternotomy wires Dermatol Surg 30 1572–1573 Occurrence Handle15606844

    PubMed  Google Scholar 

  5. K Hayashi H Kaneko S Kawachi T Saida (1999) ArticleTitleAllergic contact dermatitis and osteomyelitis due to sternal stainless steel wire Contact Dermatitis 41 115–116 Occurrence Handle1:STN:280:DyaK1Mznt1yktQ%3D%3D Occurrence Handle10445705

    CAS  PubMed  Google Scholar 

  6. CE Eastridge SS Mahfood WA Walker FH Cole SuffixJr (1991) ArticleTitleDelayed chest wall pain due to sternal wire sutures Ann Thorac Surg 51 56–59 Occurrence Handle1:STN:280:By6D1M%2FltFM%3D Occurrence Handle1985576

    CAS  PubMed  Google Scholar 

  7. N Ancalmo C Perniciaro J Ochsner (1993) ArticleTitleHypersensitivity reaction to sternal wires: a possible cause of persistent postoperative pain Cardiovasc Surg 1 439–441 Occurrence Handle1:STN:280:ByuA2MnlsVc%3D Occurrence Handle8076076

    CAS  PubMed  Google Scholar 

  8. L Peltonen (1979) ArticleTitleNickel sensitivity in the general population Contact Dermatitis 5 27–32 Occurrence Handle10.1111/j.1600-0536.1979.tb05531.x Occurrence Handle1:STN:280:CSaC38nlvV0%3D Occurrence Handle421456

    Article  CAS  PubMed  Google Scholar 

  9. H Schubert N Berova A Czernielewski E Hegyi L Jirasek V Kohanka S Korossy P Michailov L Nebenfuhrer E Prater A Rothe E Rudzki L Stranski E Suss M Tarnick E Temesvari V Ziegler E Zschunke (1987) ArticleTitleEpidemiology of nickel allergy Contact Dermatitis 16 122–128 Occurrence Handle10.1111/j.1600-0536.1987.tb01403.x Occurrence Handle1:STN:280:BiiB3Mjis1M%3D Occurrence Handle2953549

    Article  CAS  PubMed  Google Scholar 

  10. M Shah FM Lewis DJ Gawkrodger (1998) ArticleTitleNickel as an occupational allergen. A survey of 368 nickel-sensitive subjects Arch Dermatol 134 1231–1236 Occurrence Handle10.1001/archderm.134.10.1231 Occurrence Handle1:STN:280:DyaK1M%2FhvVCrtA%3D%3D Occurrence Handle9801678

    Article  CAS  PubMed  Google Scholar 

  11. J Sanchez-Perez D Ruiz-Genao I Garcia Del Rio A Garcia Diez (2003) ArticleTitleTaxi driver's occupational allergic contact dermatitis from nickel in euro coins Contact Dermatitis 48 340–341 Occurrence Handle14531877

    PubMed  Google Scholar 

  12. A Lyell WH Bain (1974) ArticleTitleNickel allergy and valve replacement (letter) Lancet 1 408–409 Occurrence Handle1:STN:280:CSuC3cjmsFY%3D Occurrence Handle4131055

    CAS  PubMed  Google Scholar 

  13. R Koster D Vieluf M Kiehn M Sommerauer J Kahler S Baldus T Meinertz CW Hamm (2000) ArticleTitleNickel and molybdenum contact allergies in patients with coronary in-stent restenosis Lancet 356 1895–1897 Occurrence Handle1:CAS:528:DC%2BD3cXovFWjsL0%3D Occurrence Handle11130387

    CAS  PubMed  Google Scholar 

  14. P Tozzi A Al-Darweesh P Vogt F Stumpe (2001) ArticleTitleSilver-coated prosthetic heart valve: a double-bladed weapon Eur J Cardiothorac Surg 19 729–731 Occurrence Handle1:STN:280:DC%2BD3M3ktF2muw%3D%3D Occurrence Handle11343965

    CAS  PubMed  Google Scholar 

  15. R Yamauchi A Morita T Tsuji (2000) ArticleTitlePacemaker dermatitis from titanium Contact Dermatitis 42 52–53 Occurrence Handle1:STN:280:DC%2BD3c7gs1ymsg%3D%3D Occurrence Handle10644034

    CAS  PubMed  Google Scholar 

  16. CK Zarins FR Arko T Crabtree DA Bloch K Ouriel RC Allen RA White (2004) ArticleTitleExplant analysis of AneuRx stent grafts: relationship between structural findings and clinical outcome J Vasc Surg 40 1–11 Occurrence Handle15218454

    PubMed  Google Scholar 

  17. Y Mu T Kobayashi M Sumita A Yamamoto T Hanawa (2000) ArticleTitleMetal ion release from titanium with active oxygen species generated by rat macrophages in vitro J Biomed Mater Res 49 238–243 Occurrence Handle10.1002/(SICI)1097-4636(200002)49:2<238::AID-JBM12>3.0.CO;2-J Occurrence Handle1:CAS:528:DyaK1MXns12ksLg%3D Occurrence Handle10571911

    Article  CAS  PubMed  Google Scholar 

  18. JJ Cavendish WF Penny MM Madani S Keramati O Ben-Yehuda DG Blanchard E Mahmud A Perricone S Tsimikas (2004) ArticleTitleSevere ostial saphenous vein graft disease leading to acute coronary syndromes following proximal aorto-saphenous anastomoses with the symmetry bypass connector device: is it a suture device or a “stent J Am Coll Cardiol 43 133–139 Occurrence Handle10.1016/j.jacc.2003.09.028 Occurrence Handle14715195

    Article  PubMed  Google Scholar 

  19. R Gerard (1955) ArticleTitleStainless steel wire as a suture material J Int Coll Surg 24 360–363 Occurrence Handle13263668

    PubMed  Google Scholar 

  20. MS Peters AL Schroeter HM van Hale JC Broadbent (1984) ArticleTitlePacemaker contact sensitivity Contact Dermatitis 11 214–218 Occurrence Handle10.1111/j.1600-0536.1984.tb00986.x Occurrence Handle1:STN:280:BiqD2M%2FhvFQ%3D Occurrence Handle6499423

    Article  CAS  PubMed  Google Scholar 

  21. U Hillen M Haude R Erbel M Goos (2002) ArticleTitleEvaluation of metal allergies in patients with coronary stents Contact Dermatitis 47 353–356 Occurrence Handle10.1034/j.1600-0536.2002.470607.x Occurrence Handle1:CAS:528:DC%2BD3sXhvV2itr0%3D Occurrence Handle12581282

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yasuko Tomizawa MD, PhD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tomizawa, Y., Hanawa, T., Kuroda, D. et al. Corrosion of stainless steel sternal wire after long-term implantation. J Artif Organs 9, 61–66 (2006). https://doi.org/10.1007/s10047-005-0321-0

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-005-0321-0

Key words

Navigation