Advertisement

Intraoperative Neuromonitoring of Recurrent Laryngeal Nerve During Thyroidectomy with Adhesive Skin Electrodes

  • Hyoung Shin Lee
  • Jungho Oh
  • Sung Won Kim
  • Yeong Wook Jeong
  • Che-Wei Wu
  • Feng-Yu Chiang
  • Kang Dae LeeEmail author
Original Scientific Report
  • 80 Downloads

Abstract

Background

Alternative methods to overcome limitations of electromyogram (EMG) tube applied for intraoperative neuromonitoring (IONM) of recurrent laryngeal nerve (RLN) during thyroidectomy have been introduced. In this study, we evaluated the feasibility of adhesive skin electrodes for IONM of RLN in patients who underwent thyroidectomy.

Methods

A total of 39 nerves at risk were prospectively enrolled in this study. Twenty-five patients with papillary thyroid carcinoma, 3 patients with follicular neoplasm, and 2 patients with Graves’ disease underwent thyroidectomy. All patients were intubated with EMG tube, and two disposable pre-gelled surface electrodes were attached to skin at both upper margins of thyroid cartilage. We followed the standard procedure of IONM, and the latency (msec) and amplitude (μV) of each signal were recorded prospectively.

Results

Intraoperative neuromonitoring using skin adhesive electrodes was successful in all nerves at risk. Amplitudes of the signals in IONM were significantly lower compared to those from EMG tube at each step of IONM, while no significant difference was identified in latency between two methods. Four nerves at risk (10.3%) showed loss of signal (<100 μV) during the steps of IONM from EMG tube, while all nerves at risk from adhesive skin electrodes showed acceptable biphasic EMG signal.

Conclusion

We verified the usefulness of adhesive skin electrodes for IONM of RLN during thyroidectomy. Although lower amplitude remains the major limitation of this technique, adhesive skin electrodes may be considered an alternative method for IONM during thyroidectomy.

Notes

Funding

This research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT & Future Planning (2017R1D1A1B03031082, 2018R1D1A1B07045831).

Compliance with ethical standards

Conflict of interest

The authors have no conflict of interest to declare.

Informed consent

All patients gave their informed consent for this study and IONM, and the institutional review board of our center admitted this study (IRB No. 2018–11-022).

References

  1. 1.
    Wong KP, Mak KL, Wong CK et al (2017) Systematic review and meta-analysis on intra-operative neuro-monitoring in high-risk thyroidectomy. Int J Surg 38:21–30CrossRefGoogle Scholar
  2. 2.
    Chan WF, Lo CY (2006) Pitfalls of intraoperative neuromonitoring for predicting postoperative recurrent laryngeal nerve function during thyroidectomy. World J Surg 30:806–812. https://doi.org/10.1007/s00268-005-0355-8 CrossRefGoogle Scholar
  3. 3.
    Sun H, Tian W, Jiang K et al (2015) Clinical guidelines on intraoperative neuromonitoring during thyroid and parathyroid surgery. Ann Transl Med 3:213PubMedPubMedCentralGoogle Scholar
  4. 4.
    Wu CW, Hao M, Tian M et al (2017) Recurrent laryngeal nerve injury with incomplete loss of electromyography signal during monitored thyroidectomy-evaluation and outcome. Langenbecks Arch Surg 402:691–699CrossRefGoogle Scholar
  5. 5.
    Chiang FY, Lee KW, Chen HC et al (2010) Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation. World J Surg 34:223–229.  https://doi.org/10.1007/s00268-009-0316-8 CrossRefGoogle Scholar
  6. 6.
    Randolph GW, Dralle H, Abdullah H et al (2011) Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope 121(Suppl 1):S1–16CrossRefGoogle Scholar
  7. 7.
    Wu CW, Chiang FY, Randolph GW et al (2018) Transcutaneous recording during intraoperative neuromonitoring in thyroid surgery. Thyroid 28:1500–1507CrossRefGoogle Scholar
  8. 8.
    Zhao Y, Li C, Zhang D et al (2018) Experimental study of needle recording electrodes placed on the thyroid cartilage for neuromonitoring during thyroid surgery. Br J Surg 106:245–254CrossRefGoogle Scholar
  9. 9.
    Chiang FY, Lu IC, Chang PY et al (2017) Comparison of EMG signals recorded by surface electrodes on endotracheal tube and thyroid cartilage during monitored thyroidectomy. Kaohsiung J Med Sci 33:503–509CrossRefGoogle Scholar
  10. 10.
    Liddy W, Lawson BR, Barber SR et al (2018) Anterior laryngeal electrodes for recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: new expanded options for neural monitoring. Laryngoscope 128:2910–2915CrossRefGoogle Scholar
  11. 11.
    Wu CW, Chiang FY, Randolph GW et al (2018) Feasibility of intraoperative neuromonitoring during thyroid surgery using transcartilage surface recording electrodes. Thyroid 28:1508–1516CrossRefGoogle Scholar
  12. 12.
    Kim DH, Lu N, Ma R et al (2011) Epidermal electronics. Science 333:838–843CrossRefGoogle Scholar

Copyright information

© Société Internationale de Chirurgie 2019

Authors and Affiliations

  • Hyoung Shin Lee
    • 1
  • Jungho Oh
    • 2
  • Sung Won Kim
    • 1
  • Yeong Wook Jeong
    • 1
  • Che-Wei Wu
    • 3
  • Feng-Yu Chiang
    • 3
  • Kang Dae Lee
    • 1
    Email author
  1. 1.Department of Otolaryngology-Head and Neck SurgeryKosin University College of MedicineBusanRepublic of Korea
  2. 2.Department of Otolaryngology-Head and Neck SurgeryHaedong HospitalBusanRepublic of Korea
  3. 3.Department of Otolaryngology-Head and Neck SurgeryKaohsiung Medical University Hospital, Kaohsiung Medical UniversityKaohsiungTaiwan

Personalised recommendations