Multiparameter Current Protections Against Ground Faults in 6 – 10 kV Cable Networks1

  • Published:
Power Technology and Engineering Aims and scope

Zero sequence current protections are most widely used for protection from single-phase ground faults in distributed 6 – 10 kV cable networks operating with an isolated neutral. Multiparametric operating principles for current protections are proposed which enhance their sensitivity in stable operation and during the most hazardous arc intermittent ground faults.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. F. A. Likhachev, Ground Faults in Networks with Isolated Neutral and Compensation of Capacitive Currents [in Russian], Énergiya, Moscow (1971).

  2. F. Kh. Khalilov, G. A. Evdokunin, V. S. Polyakov, et al., Overvoltage Protection of 6 – 35 kV Networks [in Russian], Énergoatomizdat, St. Petersburg (2002).

  3. V. A. Shuin, O. A. Sarbeeva, D. I. Shagurina, and D. I. Gandzhaev, “Use of transient electrical parameters in ground fault protection of electrical networks,” Vestn. IGÉU, No. 1, 32 – 41 (2011).

  4. M. A. Shabad, Calculations of Relay Protection and Automation of Distribution Networks [in Russian], PÉIPK, St. Petersburg (2003).

    Google Scholar 

  5. V. A. Shuin and A. V. Gusenkov, Ground Fault Protection in 6 – 10 kV Electric Networks [in Russian], NTF “Énergoprogress,” Moscow (2001).

  6. V. A. Borukhman, “Operation of selective protections against ground faults in 6 – 10 kV networks and measures to improve them,” Énergetik, No. 1, 20 – 22 (2000).

  7. Rules for construction of electrical power plants (PUÉ). Approved by decree No. 204 of July 8, 2002, of the Ministry of Énergy of the Russian Federation [in Russian], Omega-L, Moscow (2012).

  8. W. Petersen, “Der aussetzende (intermittierende) Erdschluss,” ETZ, 47, 48 (2017).

    Google Scholar 

  9. J. F. Peters and J. Slepian, “Voltages induced by arcing grounds,” Tr. AIEE, April, 478 – 493 (1923).

  10. M. S. Al-Homidi, O. A. Dobryagina, E. S. Sagurina, et al., “Evaluating the sensitivity of ground-fault current protections in 6 – 10 kV cable networks,” Vestn. IGÉU, No. 3, 50 – 55 (2016).

  11. G. S. Nudelman and M. A. Shamis, “High-speed current relay for ground-fault protection,” Élektrotekh. Prom. Ser. Apparaty Nizk. Napryazh., No. 1(92), 13 (1981).

  12. V. M. Kiskachi, S. E. Surtseva, N. M. Gorshenina, et al., “Alarm for ground-faults in 6 – 10 kV cable networks, Élektr. Stantsii, No. 4, 69 – 72 (1972).

  13. I. V. Nagai and V. I. Nagai, “Problems and solutions for remote emergency positioning of transformers for branch and intermediate substations,” Releishchik, No. 4, 30 – 35 (2009).

  14. V. M. Kiskachi, “Selectivity of ground-fault alarms using high harmonics of zero sequence currents,” Élektrichestvo, No. 9, 24 – 30 (1967).

  15. I. V. Zhezhelenko, High Harmonics in Electric Power Systems for Industrial Enterprises [in Russian], Énergoatomizdat, Moscow (2000).

  16. V. L. Vainshtein, “Study of higher harmonics of ground-fault currents,” Prom. Énerget., No. 1, 39 – 40 (1986).

  17. Al-Homidi, O. A. Dobryagina, et al., “Choice of triggering quantities for digital current protections from single-phase ground faults in medium voltage cable networks,” Vestn. IGÉU, No. 2, 21 – 29 (2015).

  18. V. F. Lachugin, Relay Protection of Power Plant Systems Based on the Use of Wave Techniques. Doctoral Thesis [in Russian], Ivanovo (2016).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. N. Golubev.

Additional information

1 This work was supported by the Ministry of Education and Science of the Russian Federation at the Ivanovo State Power Engineering University as part of the federal targeted program “Research and development in priority areas for the scientific and engineering complex of Russia during 2014 – 2020” on the topic of “Development of a complex for scientific and engineering solutions for the automatic location of single-phase ground faults in distributed 6 – 10 kV cable networks” (order number 2016-14-579-0009-150, subsidy agreement 14.577.21.0215 of October 3, 2016 and unique identifier PNIÉR RFMEFI57716X0215).

Translated from Élektricheskie Stantsii, No. 8, August 2017, pp. 36 – 45.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Golubev, A.N., Dobryagina, O.A., Shadrikova, T.Y. et al. Multiparameter Current Protections Against Ground Faults in 6 – 10 kV Cable Networks1. Power Technol Eng 51, 602–610 (2018). https://doi.org/10.1007/s10749-018-0880-x

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-018-0880-x

Keywords

Navigation