Skip to main content
Log in

Preparation and In Vitro Evaluation of Electrochemically-Aligned Collagen Matrix as a Dermal Substitute

  • Published:
MRS Advances Aims and scope Submit manuscript

Abstract

Due to injuries and disease, there is a great need for a robust, biocompatible, biodegradable, skin-like dermal substitute to repair and regenerate damaged or lost skin. A novel electrochemical process was used to fabricate planarly aligned, densely packed collagen-based sheet which closely mimics the major structure of collagen in skin. The collagen matrix was characterized by scanning electron microscopy (SEM), oxygen permeation, moisture vapor transmission rate (MVTR), and mechanical strength. The seeding and proliferation of adipose derived stem cells (ADSCs) on the matrix was also evaluated. The results indicate that electrochemically-aligned collagen matrix has good MVTR, superior oxygen permeability, and is robust and biocompatible. Thus, it will be evaluated in vivo in the near future as a dermal substitute material.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. I.V. Yannas, J.F. Burke, D.P. Orgill and E.M. Skrabut, Science 215, 174 (1982).

    Article  CAS  Google Scholar 

  2. P. Shakespeare, Burns 27, 517 (2001).

    Article  CAS  Google Scholar 

  3. V. Ottani, M. Raspanti and A. Ruggeri, Micron 32, 251 (2001).

    Article  CAS  Google Scholar 

  4. X.G. Cheng, V. Poenitzsch, L. Cornell, C. Tsao and T. Potter, Journal of Encapsulation and Adsorption Science 3, 16 (2013).

    Article  Google Scholar 

  5. X.G. Cheng, U.A. Gurkan, C.J. Dehen, M.P. Tate, H.W. Hillhouse, G.J. Simpson and O. Akkus, Biomaterials 29, 3278 (2008).

    Article  CAS  Google Scholar 

  6. C. Pailler-Mattei, S. Bec and H. Zahouani, Medical Engineering and Physics 30, 599.

  7. L. Bolton, Journal of wound, ostomy, and continence nursing : official publication of The Wound, Ostomy and Continence Nurses Society / WOCN 34, 23 (2007).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Cheng, X., Edwards, N., Leung, K. et al. Preparation and In Vitro Evaluation of Electrochemically-Aligned Collagen Matrix as a Dermal Substitute. MRS Advances 1, 1295–1300 (2016). https://doi.org/10.1557/adv.2016.240

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1557/adv.2016.240

Navigation