Background

Breast cancer mortality rates have been reduced by using mammography as standard imaging method in screening. However, the summation images due to overlapping of breast tissue result in a reduction in the mammographic performance in screening and hiding the tumor shadow within the complicated dense glandular parenchyma, resulting in lowering the sensitivity of mammography [1]. Both automated breast ultrasound (ABUS) and tomosynthesis play a great role in early breast cancer detection as well as detecting different breast lesions, specially in dense breast parenchyma and that what had been evaluated and confirmed in this study.

Aim of work

The aim of this study is to evaluate the combination of tomosynthesis and ABUS to evaluate the diagnosis, detection and classification of breast lesions; it is potential to alleviate a limitation of mammography as masking of non-calcified cancer or distortion by other dense breast.

Methods

Patient population

In this prospective study, 38 consecutive women (ages 25–74, mean age 45 +/− 9SDyear) came for early screening or presented with palpable breast mass between October 2018 and March 2019 who showed either ACR C or ACR D, with 38 breast lesions (24 malignant and 14 benign).

Data acquisition

All of the females (n = 38) were subjected to both tomosynthesis and automated breast ultrasound. In tomosynthesis, both CC and MLO views were done using GE mammography. In ABUS, coronal and axial images were taken, and in the coronal planes, AP, medial and lateral views were done using GE Invenia ABUS system (GE Healthcare).

Automated breast examination protocol design

All patients did ABUS examination. All ABUS examinations were done using transducer of 15.3 cm and 6–15 MHz frequency. The transducer length is 15.3 cm, with 6–15 MHz frequency; the examination was done while the patient was in supine position placing a cushion beneath the shoulder to evenly spread the breast tissue with the nipple pointed toward the ceiling, putting hypo-allergenic lotion on the breast mostly on the nipple.

To increase image quality and patient comfort, a disposal membrane was used to increase acoustic coupling and also by applying one of the three levels of compression. The women were told not to move or breath heavily during the scan which was continuous and automated.

Volume acquisitions were taken in the axial plane, from the inferior part of the breast with coronal and sagittal reconstruction. Three volumes were obtained for each breast anteroposterior volume with the nipple being in the center (putting a marker upon it), lateral volume involving the upper outer part of the breast with the nipple located at the intermedial corner as well as the medial volume involving the inner and inferior parts.

Tomosynthesis

Mammographic examination was performed using Senographe Essential, GE Healthcare, full-field digital mammography machine with 3D digital breast tomosynthesis. Taking both medio-lateral oblique and cranio-caudal views, images were assessed on the workstation.

Image interpretation

  • Assessment of breast density and each lesion was evaluated including the size, site, mass or asymmetry and then classified into either benign or malignant using BIRADS lexicon classification. Assessment was done by two experienced radiologists, both unaware of the pathological data of each patient.

Pathological results were taken as the gold reference standard apart from 6 lesions that were proven by HHUS criteria to be benign (1 was hamartoma, 3 were diagnosed as fibroadenomas on follow-up and 2 simple cysts). Samples were taken by either fine needle aspiration cytology (FNAC), surgical excision and core biopsy.

Statistical analysis

Data were coded and entered using the SPSS (Statistical Package for the Social Sciences) version 24. Data were summarized using frequency (count) and relative frequency (percentage) for categorical data. Standard diagnostic indices including sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. For comparing categorical data, chi-square (χ2) test was performed. Exact test was used instead when the expected frequency is less than 5. P value less than 0.05 was considered as statistically significant.

Results

This prospective study involved 38 patients presented to xxxx, their mean age was (45 ± 9) SD. Thirty-eight lesions were detected, 24 (63.2%) cases were diagnosed as malignant, while 14 (36.8%) were diagnosed as benign, using the pathological results as the gold standard reference except for 6 lesions that were proved by HHUS to be benign: 2 simple cysts, 1 hamartoma and 3 fibroadenomas on follow-up (Tables 1, 2).

Table 1 Age distribution among the studied patients
Table 2 The histological diagnosis in the patients included in our study

Each breast mass was evaluated by both tomo and automated ultrasound according to the 5th edition of BIRADS lexicon.

Tomosynthesis

As regarding detection of the lesions, 1 (7.1%) out of the 38 lesions was benign, and 3 lesions (7.9%) were not detected by tomosynthesis, whereas 2 out of the 3 lesions (8.3%) were malignant.

As regarding breast density, 6 (15.8%) were ACR D, while 32 (84.2%) were ACR C.

As regarding lesion shape, 10 (26.4%) lesions were oval, 6 lesions were round (15.8%) [5 of them = 35.7% were benign and only 1 of them was malignant 4.2%], and 19 (50.1%) were irregular; all were pathologically proven malignant. The final correlation between the shape of the lesions at tomosynthesis and the final pathology was significant (P value < 0.001).

As regarding the margin of the lesion, 14 (36.8%) lesions were circumscribed [12 (85.7%) were benign and 2 (8.3%) were malignant], 1 (2.6%) lesion had obscured benign margin, 1 (2.6%) lesion was microlobulated, 2 (5.3%) lesions had indistinct margins and they were all malignant, and 17 (44.7%) lesions had speculated margins and were all malignant. The final correlation between the margin of the lesions at tomosynthesis and the final pathology was significant (P value < 0.001).

As regarding the density of the lesion at tomosynthesis, no lesions had fat density, 6 lesions (15.8%) had low density and were benign (100%), 5 (13.2%) lesions were of equal density [2 (14.3%) were benign, 3 (12.5%) were malignant], and 27 (71.1%) lesions were of high density [6 (42.9%) lesions were benign, 21 (87.5%) lesions were malignant]. The final correlation between the margin of the lesions at tomosynthesis and the final pathology was significant (P value 0.002).

As regarding asymmetry, there was no asymmetry in 30 cases [14 (100%) of them were benign and 16 (69.6%) of them were malignant], 6 (16.2%) cases showed global asymmetry and all of them were malignant (100%), and 1 (2.7%) case showed focal asymmetry and was malignant. The final correlation between asymmetry in tomosynthesis and the final pathology was insignificant (P value 0.072).

As regarding calcification, no calcifications were detected in 23 lesions (60.5%) [12 lesions (85.7%) of them were benign and 11 were malignant (45.8%)], 3 (7.9%) lesions showed benign calcification at tomosynthesis (2 (14.3%) lesions were benign and 1 (4.2%) lesion was malignant], and 12 lesions (31.6%) had suspicious amorphous calcifications and all were malignant (100%). The final correlation between the morphology of calcifications in tomosynthesis and the final pathology was significant (P value < 0.001).

As regarding the distribution of calcification, no calcifications were detected in 23 lesions (60.5%) [12 lesions (85.7%) of them were benign and 11 were malignant (45.8%)], 5 (10.8%) lesions showed diffuse calcification [3 (14.3%) of them were benign and 2 (8.7%) were malignant], 2 (2.7%) lesion showed regional calcifications and was malignant, and 8 (21.6%) lesions showed grouped calcifications (all were malignant 100%). The final correlation between the distribution of calcifications in tomosynthesis and the final pathology was insignificant (P value 0.065).

As regarding skin thickening and retraction at tomosynthesis, there was skin thickening in 10 lesions (26.3%), while no skin thickening was noted in 28 lesions (73.7%) [14 (100%) of them were benign and 14 (58.3%) were malignant]. There was a significant correlation between skin thickening and malignancy P value < 0.001.

As regarding nipple retraction, there were 6 (16.2%) lesions with nipple retraction and 31 lesions with no nipple retraction (83.8%). There was a significant correlation between significant nipple retraction and malignancy (P value 0.037).

As regarding axillary lymphadenopathy, there was axillary lymphadenopathy in 11 cases (29.7%) and they were pathologically proven malignant. There was no significant correlation between axillary lymphadenopathy and malignant pathology (P value 0.109).

As regarding architectural distortion, it was present in 8 lesions representing 21.1% and they were pathologically proven malignant. There was a significant correlation between architectural distortion and malignant pathology (P value 0.015).

As regarding the number of lesions by tomosynthesis, no masses were detected in 3 cases (7.9%), single lesion was detected in 21 (55.3%) cases, and multiple lesions were detected in 14 (36.8%) cases.

As regarding the BIRADS evaluation by tomosynthesis, 4 (10.5%) lesions were considered BIRADS II, 1 (2.6%) lesion was BIRADS 0 for further evaluation, 12 (31.6%) lesions were reported BIRADS III, 7 (18.4%) lesions were considered BIRADS 4, and 14 (36.8%) lesions were considered BIRADS V by correlation with pathology (Fig. 1, Tables 3, 4, 5).

$$\begin{aligned} & {\text{True}}\;{\text{positive}} = 14\left( {100\% } \right)\quad {\text{False}}\;{\text{positive}} = 3\left( {12.5\% } \right) \\ & {\text{False}}\;{\text{negative}} = 0\left( {0.0\% } \right)\quad {\text{True}}\;{\text{negative}} = 21\left( {87.5\% } \right) \\ \end{aligned}$$
Fig. 1
figure 1

Correlation between tomosynthesis BIRADS and pathology

Table 3 Characterizations of lesions in tomosynthesis
Table 4 Correlation between pathology results and tomosynthesis final results
Table 5 Tomosynthesis accuracy measures

ABUS

As regarding the shape of the lesion by ABUS, 13 (34.2%) lesions were oval [11 (78.6%) lesions were benign and 2 (8.3%) lesions were malignant], 3 (7.9%) lesions were round and all were benign, and 22 (57.9%) lesions were irregular and all were malignant (78.8%). There was a significant correlation between the shape of the lesion by ABUS and pathology (P value < 0.001).

As regarding the margin of the lesion by ABUS, 14 (36.8%) lesions were circumscribed [13 (92.9%) lesions were benign and 1 (4.2%) lesion was malignant], 3 (7.9%) lesions had indistinct margins and all were malignant, 2 (5.3%) lesions had angular borders [1 lesion (7.1%) was benign and 1 lesion (4.2%) was malignant], 19 (50%) lesions had speculated margins and (100%) all of them were malignant). There was a significant correlation between the margin of the lesion by ABUS and pathology (P value < 0.001).

As regarding orientation of the lesion, 15 (40.5%) lesions were parallel [14 (100%) lesions were benign and 1 (4.3%) lesion was malignant] and 22 (59.5%) lesions were non-parallel and all were malignant. There was a significant correlation between orientation of the lesion by ABUS and pathology (P value < 0.001).

As regarding echo pattern of the lesion, 1 (2.7%) lesion was anechoic and it was benign, 29 (78.4%) lesions were hypoechoic [10 (71.4%) lesions were benign and 19 (82.6%) were malignant], 3 (8.1%) lesions were isoechoic [1 (7.1%) was benign and 2 (8.7%) were malignant], 3 (8.1%) lesions were heterogeneous [2 were benign (14.3%) and 1 (4.3%) was malignant], and 1 (2.7%) lesion was benign complex solid and cyst. There was an insignificant correlation between lesion echo pattern by ABUS and pathology (P value 0.481).

As regarding posterior features of the lesions, no posterior features in 23 lesions (62.2%) [12 (85.7%) lesions were benign and 11 (47.8%) were malignant], 6 (16.2%) lesions showed posterior enhancement [2 (14.3%) were benign and 4 (17.4%) were malignant], and 7 (18.9%) lesions showed posterior shadowing and all were malignant. One (2.7%) lesion showed combined pattern of posterior shadowing and enhancement, and it was malignant (100%). There was an insignificant correlation between the posterior features of the lesion by ABUS and pathology (P value 0.074).

As regarding calcifications of the lesions, there were no calcifications in 37 (97.4%) lesions, and there was calcification in 1 lesion (2.6%). There was an insignificant correlation between calcification in mass and malignancy (P value 0.439).

As regarding axillary lymphadenopathy detection by ABUS, axillary lymphadenopathy was detected by ABUS in 8 (21.1%) [2 (14.3%) were benign and 6 (25%) were malignant], while no axillary lymphadenopathy was seen in 30 (78.9%) cases [12 (85.7%) were benign, while 18 (75%) were malignant]. There was no significant correlation between axillary lymphadenopathy by ABUS and pathology (P value 0.435).

As regarding margin of the lesions in coronal view that is unique view for ABUS examination, 15 (39.5%) lesions showed complete hyperechoic rim [12 (85.7%) were benign) and 3 (12.5%) were malignant], 5 (13.2%) lesions showed retraction phenomenon (all were malignant 100%), and 18 (47.4% lesions showed incomplete (discontinuous) hyperechoic rim [2 (14.3%) were benign, while 16 (66.7%) were malignant]. Specificity of retraction phenomena for malignant lesions was 100%, while sensitivity was 75%. The sensitivity of hyperechoic rim for benign lesions was 52.8%, while the specificity was 90.5%.

As regarding numbers of the lesion by ABUS, no masses were detected in 3 (7.9%) cases, single lesion was detected in 17 (44.7%) cases, and multiple lesions were detected in 18 (47.4%) cases.

Eleven lesions (28.9%) showed skin thickening by ABUS and all were malignant (100%), while no skin thickening was noted in 27 (71.1%) lesions [14 (100%) were benign, while 13 (54.2%) were malignant]. The correlation between skin thickening and malignant pathology was significant (P value 0.003) (Figs. 2, 3, 4, 5, Tables 6, 7, 8, 9, 10, 11, 12).

Fig. 2
figure 2

Correlation between ABUS BIRADS and pathology

Fig. 3
figure 3

Comparison between accuracy measures of tomosynthesis and ABUS

Fig. 4
figure 4

A and B: Digital Mx CC and MLO views of the right breast show an oval-shaped circumscribed high-density UOQ mass with no associated skin thickening. C and D: Tomosynthesis CC and MLO views of the right breast confirmed the mammographic findings, however, with better delineation of the margins (BIRADS IV). E: Automated ultrasound right AP coronal image shows small focal defect at distance 28.3 mm from the nipple. F: Automated ultrasound image shows a right rather well-defined mass, non-parallel orientation and heterogeneous echo pattern (BIRADS V). Core biopsy was done and revealed adenocarcinoma. Automated ultrasound was superior to tomosynthesis in characterization of the lesion, while tomosynthesis was superior in detection of right axillary lymphadenopathy

Fig. 5
figure 5

A 42-year-old female patient presenting with tender right breast. Tomosynthesis CC and MLO views of the right breast confirmed the previously described mammographic findings (not shown), however, with less fibroglandular tissue overlap and thus better delineation of the margins (BIRADS III). Automated ultrasound right medial coronal image shows a large defect at 2:30 o’clock. Automated ultrasound right medial axial image shows a right oval-shaped mass with indistinct margin, parallel orientation and hypoechoic echo genic cyst (BIRADS III). The lesion was proved to be inflammatory mastitis with acute abscess formation by aspiration of the abscess content. Automated ultrasound was superior to tomosynthesis in predicting the exact pathology

Table 6 Characterizations of the lesions (ABUS)
Table 7 Correlation between ABUS BIRADS and pathology
Table 8 ABUS accuracy measures
Table 9 Comparison between accuracy measures of ABUS and tomosynthesis
Table 10 Agreement between tomosynthesis and ABUS BIRADS
Table 11 Correlation between lesion size and pathology at tomosynthesis
Table 12 Correlation between lesion size and pathology at ABUS

Eight lesions (21.6%) showed nipple retraction by ABUS, and all were malignant (100%). While no nipple retraction was noted in 29 (78.4%) lesions [14 (100%) were benign, while 15 (65.2%) were malignant], the correlation between nipple retraction and malignant pathology was significant (P value 0.013).

$$\begin{aligned} & {\text{False}}\;{\text{positive}} = 0\left( {0\% } \right)\quad {\text{True}}\;{\text{positive}} = 14\left( {100\% } \right) \\ & {\text{True}}\;{\text{negative}} = 23\left( {100\% } \right)\quad {\text{False}}\;{\text{negative}} = 0\left( {0\% } \right) \\ \end{aligned}$$

This table shows a positive significant correlation between the size of the lesions at tomosynthesis and ABUS (0.4). The intraclass correlation coefficient as regarding the size of the lesions (longest dimension) between ABUS and tomosynthesis is 0.325. There is no significant correlation between lesion distance from nipple at tomosynthesis and ABUS (P value = 0.330). There is no significant correlation between lesion distance from skin at tomosynthesis and ABUS (P value = 0.776).

Discussion

The role of breast imaging radiologist is very important as cancer breast is the most common malignancy in both developing and developed countries, so mammography remains the gold standard imaging in screening and early detection [2].

As a result of the 3D imaging capabilities of tomosynthesis, it plays an important role in screening and diagnosis of breast lesions, alleviating the limitation of mammography in masking cancers by dense breast tissue [3]. Tomosynthesis provides better imaging quality and accuracy in detection and classification of the lesions [4].

Ultrasonography is used in conjugation with mammography in detection and assessment of breast lesions as it is an inexpensive, noninvasive and non-ionizing imaging modality. However, it is operator dependent and image evaluation should be done during the procedure [5].

Nowadays, ABUS is used for breast evaluation, as it is an operator-independent US imaging with a high-resolution transducer [5].

The study of Poplack et al. [6], which included 98 women with abnormal mammography, had compared mammography with tomosynthesis in image quality and recall rates of screening. The results reported that tomosynthesis has superior or comparable image quality to that of mammography and reduces the recall rate when used with digital screening mammography [6].

Andersson et al. [7]’s study, in Canada on 36 patients, compared the breast cancer visibility in one-view tomosynthesis to cancer visibility in one- or two-view digital mammography (DM). The results indicated that the cancer visibility on breast tomosynthesis (BT) is superior to DM, which suggests that BT may have a higher sensitivity for breast cancer detection [7].

A comparison had been made in a study done by Gennaro et al. [8] in Italy, between the full-field digital mammography (FFDM) and the clinical performance of digital breast tomosynthesis (DBT), which showed that the clinical performance of tomosynthesis in one view at the same total dose as standard screen-film mammography is not inferior to digital mammography in two views [8].

Hakim et al. [9] examined 25 females and compared DBT to the additional mammographic views in different lesions characterization, asymmetries and architecture distortion and concluded that DBT could be an alternative to additional mammographic views in most patients.

Spangler et al. [10] proved in a study done on 100 patients that the FFDM is still more sensitive than digital tomosynthesis in detection and characterization of calcifications.

However, a study made by Zhang et al. [11] on a large sample (182) reported that tomosynthesis had more diagnostic accuracy for non-calcified lesions in comparison with additional mammographic views.

Teertstra et al. [12] study was done in the Netherlands on 519 cases and proved that tomosynthesis can be used as an additional technique to mammography in patients referred with an abnormal screening mammogram or with clinical symptoms.

A study was done by Kim et al. [13] on 119 patients, which proved that digital breast tomosynthesis could detect similar lesion characterization performance compared to that of US for the lesions depicted on digital mammography (DM).

The retrospective study of Krammer et al. [14] proved that digital breast tomosynthesis (DBT) could improve the preoperative breast cancer staging in dense breast patients compared to conventional mammography alone. However, limitations have to be expected in the case of invasive lobular carcinoma [14].

Kelly et al. [15] compared the mammographic diagnostic performance to that of the automated breast ultrasound (ABUS) in dense breast and resulted in significant cancer detection improvement by ABUS compared with mammography alone.

Another study retrospectively depicted that ABUS had higher performance in detecting malignant lesions with their surrounding changes than benign lesions [16].

The study of Lin et al. [17], which was performed in China on 81 cases, compared the clinical utility of ABUS against HHUS in breast lesion detection and proved that ABUS had high diagnostic accuracy, operator independence and better lesion size.

A similar study was conducted on 175 patients, and it evaluated the differences in the diagnostic values of the conventional handheld B-mode ultrasound (HHUS) and automated breast ultrasound (ABUS) for benign and malignant breast masses and compared it with the final pathologic findings. It showed that overall ABUS and HHUS do not differ in diagnostic accuracy for the differentiation of malignant or benign breast masses [5].

Giuliano et al. [18] study was performed in 3418 asymptomatic women with mammographically detected dense breasts and proved that ABUS could be used in conjunction with mammography in the dense breast screening population study.

Giger et al. [19] compared the performance of breast cancer detection using full-field digital mammography (FFDM) alone and using FFDM with ABUS. The study included 185 cases, 133 non-cancers and 52 biopsy-proven cancers. They concluded that combining mammography with ABUS compared with mammography alone had significantly improved readers’ detection of breast cancers in women with dense breast tissue without substantially affecting specificity [19].

The current research was a prospective study conducted on 38 patients presenting with dense breast masses either discovered clinically or discovered by mammographic examination as a part of the early detection program. They have been evaluated by means of digital breast tomosynthesis and automated breast ultrasound, 38 masses were detected in the 38 patients, and pathological confirmation was done in most masses (n = 31/38) and ultrasonography confirmation in the rest (n = 7 /38): simple cysts, fat containing lesion (hamartoma) and fibroadenomas.

Image data analysis from both automated ultrasound and tomosynthesis was performed by two radiologists independently, and the findings were reported as per the morphology descriptors used in the BIRADS lexicon. The data were interpreted as regards the location, extension of the lesions, mass number, shape, margin, skin retraction and thickening, and the presence of calcification, and a final score was given according to the BIRADS assessment categories. The specificity and sensitivity of each modality in characterization and detection of breast lesions were detected.

Our study included 38 females presenting with different types of breast lesions.

Thirty-eight masses were detected, among which 14 were benign (n = 14/38) and 24 were malignant (n = 24/38).

Histopathology of the masses was reached using different techniques such as core biopsy (n = 24), FNAC (n = 6) and excisional biopsy (n = 2). The rest of the masses (n = 6/38) were confirmed by their characteristic sonographic appearances: anechoic simple cysts and mixed echogenicity hamartoma.

Different pathologies were identified, some of which were benign such as fibroadenoma, simple cysts, hamartoma, inflammatory mastitis and focal fibroadenosis. The latter was falsely diagnosed by tomosynthesis as a mass due to its circumscribed margin.

Others were malignant, such as invasive duct carcinoma (commonest type of malignancy in our study 28.9%), invasive lobular carcinoma, invasive mammary carcinoma and duct carcinoma in situ. The latter was the most difficult to detect in this study due to the subtle changes of ductal dilatation.

Among our cases, two were metastatic breast masses. One of them was female patient who gave a history of cancer colon; the mass appeared irregular with speculated margins, so malignant nature was suspected, then core biopsy was done, and histopathology revealed metastatic adenocarcinoma. On the contrary, the other metastatic breast mass was circumscribed with no available data regarding any history of malignancy, and histopathology revealed metastatic melanoma.

Six masses were diagnosed by their characteristic sonographic findings; 2 of them were simple cysts with the characteristic anechoic nature and posterior enhancement, and 1 was hamartoma with their special imaging features (fat containing mass which resembles breast within the breast), and 3 were fibroadenomas with characteristic hypoechoic oval lesion.

According to the newest BIRADS lexicon criteria in the description of malignant masses, 22 masses were irregular on both modalities and were proved to be malignant, yet tomosynthesis underestimated one case since it showed rounded mass (normally to a benign descriptor). On the other hand, fine speculation was detected on automated ultrasound images and proved by core biopsy to be malignant in nature.

We found out that the sensitivity of ABUS was 87% regarding the malignant lesion shape characterization in comparison with tomosynthesis which showed 69.6% sensitivity.

Regarding the margins, 92.9% of the circumscribed masses were benign and 100% of the speculated masses were malignant in our study. Despite that three masses were circumscribed on both modalities, their histopathology results proved them malignant. This confirmed that a single criterion was not enough for radiologists to reach a correct final diagnosis. Tomosynthesis showed 87.5% sensitivity, while ABUS showed 100% sensitivity in the current study.

Regarding the number of masses, tomosynthesis detected multiple lesions in about 14 out of 18 cases, while automated ultrasound was able to detect the whole 18 cases.

Although most of the masses were seen on both modalities, tomosynthesis missed one case, yet it was visible by automated ultrasound as a very small irregular mass.

ABUS showed 23.7% in the category of detecting mass extension, while tomosynthesis showed 31.6%.

For the skin thickening and retraction, tomosynthesis was sensitive in 26.3%, while automated ultrasound was sensitive in 28.9%.

As regards the final BIRADS score given for both modalities, tomosynthesis showed an accuracy of 92.1% in characterization of malignant masses with an accuracy of 100% in benign masses; on the other hand, automated ultrasound showed 100% accuracy in characterization of malignant masses with 100% accuracy in benign masses.

In summary, we detected in the current study that the sensitivity of tomosynthesis in characterization and detection of breast lesions was 87.5%; both the specificity and PPV were 100%, while the negative predictive value was 82.4%. On the other hand, ABU showed 100% in all the sensitivity, the specificity, PPV and NPV.

Our study succeeded to prove that ABUS is a reliable screening and diagnostic imaging tool. It could detect different breast lesions and abnormalities whether benign or malignant, showed improvements in cancer detection rates, decreased the need for further assessments, reduced the false positive rates, and showed superior performance compared to digital mammography, in lesion detection, characterization, tumor margins and extent, multifocality and multi-centricity of the malignant lesions, and image quality, especially in dense breast lesions.

Conclusion

ABUS in addition to tomosynthesis can make a revolution in breast screening and diagnostic performance, specially in women with dense breasts.