Background

Radiotherapy is one of the treatments options that are frequently indicated in the treatment of patients with head and neck carcinomas (Nutting 2016). Its adverse effects on the patients’ general health and their quality of life are, however, quite significant (Yucel et al. 2014). Secondary effects of radiotherapy on the oral tissues have been studied widely. It is well acknowledged that radiotherapy can cause damage to any normal tissue located within the radiation field (Barnett et al. 2009). The change in the properties of the different dental restorative materials is one of the adverse effects of the head-and-neck radiotherapy, especially with increasing radiation doses (Brandeburski and Della Bona 2018).

Although resin composites have shown a substantial evolution over the past years, the development of new composites has mainly focused on the increase in the filler’s percentage. In general, increasing filler percentage within contemporary resin composites was found to adversely influence the degree of conversion (Rastelli et al. 2012; Halvorson et al. 2009). It was also observed that flexural strength of resin-based composites is greatly affected by the filler system characteristics, including filler percentage (Kim et al. 2002; Beun et al. 2007).

In the oral environments, resin composites are exposed intermittently or continuously to chemical agents in saliva, food, and drinks which can cause softening of the resin matrix of the composite resin restorations through water absorption, which causes hydrolytic breakdown of the bond between the filler particles and resin matrix, and eventually de-bonding of the fillers (Ferracane et al. 1998). The medium to which the composite is exposed to, controls the de-bonding mechanism and the resultant loss in material’s properties. To simulate the effect of chemicals in the oral environment, several artificial storage procedures such as artificial saliva, acids or ethanol solutions have been used as in vitro storage media (Wu and McKinney 1982).

The properties of resin composites under the different clinical conditions can be evaluated in vitro by the assessment of their mechanical and physical properties. In this regard, the aim of this study was to evaluate the effect of radiation exposure and storage time on the DC% and the FS of three different resin composites. The null hypothesis tested was, neither the radiotherapy, nor the storage time has an effect on the DC% and FS of the three different resin composites.

Methods

Three different nano-hybrid resin composites were used in this study. Materials, manufactures, composition, and Lot # are presented in Table 1.

Table 1 Materials, manufactures, composition/filler weight %, and Lot #

Study design

In total, 90 resin composite disk-shaped and 360 rod-shaped specimens were prepared to evaluate the DC% and FS, respectively. The specimens were divided into 18 groups (n = 5/group for DC% and n = 20/group for FS) according to the three experimental factors of this study: Factor 1: Radiation, 2 groups (no-exposure and radiation exposure), Factor 2: Resin composite, 3 groups (Herculite XRV Ultra, Z250 XT and Grandio), and Factor 3: storage time, 2 groups (24-h in distilled water, 3-m, and 6-m in 70% ethanol).

Preparation of the composite specimens

For the DC%, a specially fabricated stainless-steel circular split mold with a central hole measuring 5 mm diameter × 2 mm thickness was used. The mold was positioned on a glass slide that was covered with a Mylar strip. The investigated resin composite materials were applied inside the mold in a single increment, covered with another Mylar strip, and the resin composites were pressed using glass slide to extrude the excess material and obtain a flat smooth surface. The materials were light-cured for 20 s according to manufacturer’s instructions using LED light curing device, with an output of 1200 mW/cm2 (Elipar™ DeepCure-L Light Cure, 3 M ESPE, St. Paul, USA.). The intensity of the LED unit was periodically checked every 10 specimens using a hand-held radiometer (CM300-2000, APOZA, Taiwan). A 1200-grit SiC paper was used to remove any flashes from the prepared composite specimens.

For the FS, a specially fabricated rectangular stainless-steel split mold with a central rectangular window measuring 12 mm length × 2 mm width × 2 mm thickness was used. The mold was positioned on a glass slide that was covered with a Mylar strip. Resin composite materials were applied, covered with another Mylar strip, and the resin composite was pressed using a glass slide to extrude the excess material and obtain a flat smooth surface. Each specimen was light-cured for 20 s according to the manufacturer’s instructions using the LED curing device. To ensure proper polymerization for each specimen, two overlapping light curing cycles was used, each cycle for 20 s for a total curing time of 40 s. The top surface of each specimen was marked using a permanent marker before removing from the mold. The dimensions (width × thickness × length) of each specimen were measured using a digital caliper (Absolute AOS Digimatic, Mitutoyo, Tokyo, Japan) with an accuracy of 0.01 mm at three different locations along the length of the specimen. The values of the three measurements were averaged for each specimen to be used in the FS determining equation.

Storage of the composite disks

The specimens were randomly assigned to the three storage times (24 h in distilled water, 3-m and 6-m in 70% ethanol solution). Specimens were stored in light-proof container in an incubator at 37 °C (TITANOX, Via Canove, Italy). For specimens stored in 70% ethanol, the ethanol solution was replaced every 1 week to avoid saturation by degradation products and partial evaporation of the ethanol solution (Kao 1989).

Radiation exposure of the composite specimens

After each storage time, half of the specimens from each material were evaluated without being subjected to the radiation exposure dose. The other half was subjected to 60 Gy of gamma radiation a single fraction. Specimens assigned for exposure to radiation were first blot dried then embedded in pink modelling wax sheets. Their top surfaces were flushing with the wax surface. This was done in order to ensure intimate contact with the phantom (a human tissue equivalent material), to minimize radiation errors and to ensure dose homogeneity. Another phantom of 5 mm thickness was placed above the wax to allow for radiation build-up. Gamma rays radiation was performed with an average of (1.25 MeV) emitted from a cobalt-60 machine (Theraton Phoenix 60 Cobalt Radiotherapy Treatment Unit—Theratronics International, Ltd., Atomic Energy of Canada, Ltd., AECL Medical, Ontario, Canada) using a single anterior field at a source–surface distance (SSD) of 80 cm and with a maximum field size of 35 × 35 cm. Radiation dose of 60 Gy was delivered as one shot.

Determination of the Degree of conversion (DC%)

The assigned specimens were grounded into fine powder. Fifty microgram resin composite powder was mixed with 5 mg of Ispectropic grade (IR) potassium bromide powder (KBr) in 1:10 ratio. The mixture was placed in a pellet maker kit (KBr Product-A-Press, International Crystal Labs, Garfield, NJ, USA) and pressed to obtain a 1-mm-thick pellet. Fourier transform infrared spectrometer (JASCO FT/IR 4600, Japan) (FTIR) was used to determine the DC%. The spectra were recorded using 24 scans at 4 cm–1 in absorbance mode and 400–4000 cm–1 wavelength. The percentage of unreacted carbon–carbon double bonds (% C=C) in the cured composite specimens was determined from the ratio of peak areas of aliphatic C=C (1638 cm−1) against the aromatic component (1608 cm–1), which was used as an internal standard. The underlying peak area was calculated for each peak using a standard baseline technique with the aid of computer software program provided with the spectrometer (JASCO Spectral Analysis, Japan). To obtain the spectrum of the uncured resin composite, the composites paste was directly mixed with the potassium bromide powder in the same ratio described for the cured specimens. The DC% for each group was determined using the following equation:

$${\text{DC }}\% = 1 - \left[ {\frac{{{\text{abs}}\left( {{\text{aliphatic}} \,C = C} \right)/{\text{abs}}\left( {{\text{aromatic}} \,C = C } \right)] {\text{cured}} }}{{{\text{abs}}\left( {{\text{aliphatic}} \,C = C} \right)/{\text{abs}}\left( {{\text{aromatic}} \,C = C } \right)] {\text{uncured}} }}} \right] \times 100.$$

Flexural strength (FS) testing

Specimens were subjected to a three-point bending test in a universal testing machine (Shimadzu 5KN (Autograph AG_X Plus, Japan). Each specimen was placed on a specially fabricated stainless-steel holder that consisted of two vertical rods, acting as supports, mounted parallel to each other above a flat base with the distance of 10 mm between centers of their apices. Another single stainless-steel rod was attached to the upper jig of the universal testing machine to apply vertical striking force directly on the center of the top surface of the composite specimens. The test was run at crosshead speed of 1 mm/min until failure. FS (σ), in mega-pascals (MPa), was calculated using the following formula:

$${{\varvec{\upsigma}}} = {\mathbf{3}} \, {\mathbf{Fl}}/{\mathbf{2bd}}^{{\mathbf{2}}}$$

where F is the maximum load at the point of fracture (Newton), l is the distance between the two supports (10 mm), b is the width of specimen measured prior to testing (2 mm), and d is the thickness of the specimen measured prior to testing (2 mm).

Statistical analysis

Statistical analysis was performed using IBM statistical software for Windows (Version 21). The significance level was set at P = 0.05. Data was analyzed using Three-Way ANOVA to evaluate the effect of factors “radiation”, “resin composite”, “storage time” and “radiation × resin composite × storage time). One-Way ANOVA followed by Tukey’s HSD post hoc test was used for pairwise comparison in resin composites and storage periods. Independent student t test was used to compare between radiation no-exposure and radiation exposure groups.

Results

For the DC% results, three-way ANOVA (Table 2) showed that factors “radiation”, “resin composite”, and “storage time” had statistically significant effect on DC% (P < 0.001). On the other hand, factor “radiation × resin composite × storage time” revealed no statistically significant difference on the DC% (P > 0.05).

Table 2 Three-way ANOVA analyzing the effect of radiation, material, storage, and their interaction on DC%

One-way ANOVA showed that for factor radiation exposure (Table 3), there was no statistically significant difference between no-radiation exposure and radiation exposure treatments (P > 0.05). Regarding factor resin composite (Table 4), Herculite XRV Ultra revealed the highest statistically significant DC%, while Grandio showed the least statistically significant value among all tested resin composites (P < 0.05). For factor storage time (Table 5), there was no statistically significant difference between 3-m and 6-m storage times (P > 0.05). Both 3-m and 6-m storage times showed statistically significant higher DC% compared to 24-h storage time (P < 0.05).

Table 3 Mean ±  standard deviations for the effect of radiation on DC%
Table 4 Mean ±  standard deviations for the effect of material on DC%
Table 5 Mean ±  standard deviations for the effect of storage on DC%

For the FS results, three-way ANOVA (Table 6) showed that factors “radiation”, “resin composite”, “storage time”, and “radiation × resin composite × storage time” had statistically significant effect on FS of the different resin composites (P < 0.05).

Table 6 Three-way ANOVA for the effect of radiation, material, storage, and their interaction on FS

One-way ANOVA showed that for factor radiation (Table 7), radiation exposure showed a statistically significant higher FS (P < 0.05). Regarding the factor resin composite (Table 8), there was no statistically significant difference between Grandio and Z250 XT (P > 0.05), and both materials showed a statistically significant higher FS compared to Herculite XRV Ultra (P < 0.05). Regarding the factor storage time (Table 9), there was a statistically significant difference between the different storage periods (P < 0.05). 24-h storage time showed the highest value, while 6-m storage showed the least FS value.

Table 7 Mean ± standard deviations for the effect of radiation on FS
Table 8 Mean ±  standard deviations for the effect of material on FS
Table 9 Mean ± standard deviations for the effect of storage on FS

Discussion

Patients receiving radiotherapy in the head and neck region usually become higher-risk candidates of developing more dental diseases, and thus the selection of dental restorative materials is of paramount importance in order to prevent any deleterious interactions between the incident radiotherapy on the properties of the restorative material. In this regard, the testing of different properties of resin composite materials that were exposed to radiation dose is thus mandatory (Toth et al. 1991).

The results of this study rejected the null hypothesis, as factors “radiation”, “material”, and “storage time” had significant effects on both DC% and FS of the tested resin composites.

From the results of this study, factor radiation exposure showed no statistically significant effect on the DC% of the different resin composite, regardless to the different storage times (Table 3). The DC% is a material dependent property (Par et al. 2019; Erdemir et al. 2013). Variation in the chemistry and formulations of organic matrix and different filler features such as mass fraction, density, and particle size, shape, and distribution; were found to contribute to the variable significant differences in the final DC% of the investigated resin composites. (Abed et al. 2015; Turssi et al. 2005; Amirouche-Korichi et al. 2009). When resin composites were light-cured, the DC% could be expected to reach its maximum value before exposure to the therapeutic radiation dose (Cruz et al. 2008), and that no changes in the chemical structure of the investigated resin composites could occur following radiation exposure. The results of this study came in agreement with the results of Cruz et al. (2008). They reported that there was no change detected in the DC% of the studied resin composites after exposure to different doses of radiation. On the other hand, the results of this study disagreed with the studies of Hsiue and Chang (1993), Campos et al. (2015), Cruz et al. (2009) and Haque et al. (2001). They reported significant changes in the final DC% of the tested photo-polymerized resin composites after exposure to different doses of the ionizing radiations. These disagreements could be contributed partly to the difference in resin composites’ formulations used and partly to the difference in radiation doses, into which some studies used lower doses of radiation (Campos et al. 2015; Cruz et al. 2009), while the other studies used higher radiation doses than the ones used in the present study (Hsiue and Chang 1993; Haque et al. 2001).

It was reported that therapeutic radiation could induce a post-cure reaction, which occurred because some portions of the free radicals generated during composite polymerization could be trapped within the heterogeneous network and might persisted for extended periods (Burtscher 1993). Furthermore, resin composites’ DC% could be continued after light-curing, but at a slower rate (Schneider et al. 2006). Such contradiction could be associated with the different tested resin composite materials in these studies. The possibility of the incident gamma radiation beam to yield any molecular disruption might be overcame by the high energy created by carbon-to-carbon single bond in the polymeric network (Arener 1974). Additionally, this could be owed to the process by which the gamma radiation is absorbed by the inorganic filler particles and the radiosensitive chemical groups in the resin composites. As the gamma radiation will spread within the resin composites into their organic resin matrix leading to excitation and ionization of the matrix and development of coupled reactive species (chemical reagents starters or initial chemical reagents). Due to the limited molecular mobility inside the photo-polymerized resin composite materials network, the chemical reagents would only link among themselves creating new chains or link with and stabilize the closer chemical groups (Hsiue and Chang 1993; Haque et al. 2001; Cruz et al. 2009; Behr et al. 2005). This might affect other mechanical properties of the resin composites but would not increase their DC% (Cruz et al. 2008).

Regarding the effect of factor radiation exposure on the flexure strength of the different resin composites, radiation exposure resulted in statistically significant higher FS values (Table 7). Flexure strength is a structurally sensitive property that could be easily affected by lattice defects and voids. Novais et al. (2015) found some decrease of FS after the irradiation protocol and reported that explanation of their results was difficult to be addressed. Catelan et al. (2008) evaluated the effect of radiotherapy on FS of resin composite, and they demonstrated that the flexural strength had a tendency toward gradual increase in radiation values up to a dose of 50 Gy while it started to decline with higher doses, such as 60 Gy. Consequently, ionizing radiation with doses ranging from 25 to 200 Gy was found to be capable of modifying the microstructure of dental composites and improve their properties as well (Behr et al. 2005; Vaishnavi et al. 2010). It was reported that radiation exposure might be able to reorganize the residual chemical groups of low molecular weight inside the polymer matrix to obtain a beneficial effect (Von-Fraunhofer et al. 1989), which in turn might explain the significant increase in FS in the present study. Moreover, Vaishnavi et al. (2010) concluded that mechanical properties of dental composites irradiated with higher doses would further optimize the material properties, which came in agreement with the results of the present study.

On the other hand, the results of this study disagreed with the study of Haque et al. (2001). They found that FS was not improved by the exposure to gamma radiation. The difference in resin composites used might be the reason of such disagreement.

Regarding the effect of factor resin composite material on the DC%, Herculite XRV Ultra had a significantly higher DC% values compared to Z250 XT and Grandio (Table 4). This difference in the compositions of the tested resin composites in this study could play a major role in the difference in the DC% values of the tested composites (Abed et al. 2015). It was reported that different monomers exhibit different DC%, in the following increasing order: BIS-GMA < BIS-EMA < UDMA < TEGDMA (Sideridou et al. 2002). BIS-GMA, the strong intramolecular hydrogen bonding of its hydroxyl groups (-OH) and the presence of rigid aromatic nuclei interactions given by the aromatic rings in its structure are the reasons for being the most viscous and least flexible monomer. On the other hand, UDMA is a less viscous, and a more flexible monomer compared to BIS-GMA and thus has increased the reactivity and higher DC% was obtained. This is because of the weak hydrogen bond of its amine group compared to that of the hydroxyl groups present in BIS-GMA (Khatri et al. 2003). Also, characteristic chain transfer reactions might exist due to the presence of the amine groups in its urethane structure of UDMA, which could provide an alternative path for the continuation of polymerization and hence increase the monomer conversion (Sideridou et al. 2002). Regarding the TEGDMA, it has the least viscosity and the highest DC% among the different monomer systems and considered as the main contributor for polymerization (Floyd and Dickens 2006; Sgarbi et al. 2010). TEGDMA has a better plasticizing effect on BIS-GMA than UDMA and BIS-EMA, which could result in a synergistic effect of components of BIS-GMA/TEGDMA organic matrix mixture on the polymerization rate (Sideridou et al. 2002). Herculite XRV Ultra contains a higher TEGDMA/BIS-GMA ratio, which could enhance its flowable consistency (Alshali et al. 2013). On the other hand, Z250 XT contains the high molecular weight BIS-EMA monomer in addition to BIS-GMA and UDMA monomers. BIS-EMA is a bulky monomer with a stiff central phenyl ring core that might enhance the mechanical performance of the material, yet it can significantly restrict the mobility of UDMA monomers and decrease their reactivity and ultimate conversion value (Alshali et al. 2013).

Additionally, Herculite XRV Ultra has the least filler wt% compared to Grandio and Z250 XT. Increasing the filler wt% in the resin composite material resulted in a decrease in DC% (Halvorson et al. 2009). Light penetration was found to be more in case of low-filled composites than denser ones. Light transmission within the resin matrix could be considerably attenuated by the frequent scattering caused by the densely distributed fillers within the resin matrix of the resin composites (Turssi et al. 2005). Additionally, high filler load might have contributed to lower DC% values by decreasing the composite’s translucency (Bucuta and Ilie 2014). Correspondingly, Grandio resin composite exhibits the higher filler loading among all tested resin composites. Increasing amounts of the inorganic filler could increase the overall surface area contacted by the polymerizing matrix phase. Therefore, the polymer mobility in its immediate vicinity could be restricted (Halvorson et al. 2009; Rastelli et al. 2012), reducing the linking potential between the polymer chains which would finally result in lower monomer conversion results (Shah and Stansbury 2014).

On the other hand, there was a statistically insignificant difference between Z250XT and Grandio in their FS, which both materials showed a statistically significant higher FS compared to Herculite XRV Ultra (Table 8). According to Kim et al. (2002), the filler system characteristics have a great influence on the different mechanical properties of resin composites. Moreover, increasing the filler content of a resin composite could lead to an increase of the Young’s modulus, thus its resistance to deformation improved (Beun et al. 2007). Generally, strength and fracture energy increased by the presence of a closely spaced disperse phase in a brittle material. In addition, the presence of filler particles in the crack path resulted in cracks pinning (Belli et al. 2014), which led to a significant toughening mechanism in the nanocomposites (Albdiry et al. 2013). On the contrary, Park et al 2014, found a low correlation between FS and filler content, highlighting the fact that FS depended more on the presence of internal defects such as cracks or voids that were generated during manufacturing process of the dental composites (Mecholsky 1995; Bona et al. 2003). Grandio and Z250 XT contain higher filler wt% compared to Herculite XRV Ultra, according to their manufacturers. Furthermore, the presence of pre-polymerized fillers in Herculite XRV Ultra might contribute to lower FS of the material, which was observed in previous studies (Randolph et al. 2016; Blackham et al. 2009). Pre-polymerized fillers lack active binding sites and are difficult to silanize resulting in poor integration in the resin matrix (Randolph et al. 2016). The bond between pre-polymerized fillers and the polymer matrix is thus regarded as a weak spot, capable of causing reduction in strength properties (Ferracane 1995). Grandio showed a higher yet statistically insignificant difference when compared to Z250 XT, which might indicate that the effect of its higher filler wt% was offset by other factors. The presence of aromatic cycles in monomers like Bis-GMA and Bis-EMA in Z250 XT composite, resulting in reduced cyclization and increased cross-linking in the polymer, hence the mechanical properties could be improved (Sideridou et al. 2002). Moreover, the presence of zirconium fillers and small sized filler particles might contribute to increased mechanical strength due to increased filler surface area to the filler particle content (Halvorson et al. 2009).

For the effect of factor storage time on the DC% of the different resin composites, the results showed that both 3-m and 6-m storage time exhibited statistically significant higher DC% values compared to 24-h storage time (Table 5). An increase in the DC% was observed over time (Mohamad et al. 2007; Ghavami-Lahiji et al. 2018; Tonetto et al. 2013), with the highest value was found at 7 days after the initial light curing of resin composites post-curing (Tonetto et al. 2013). Leprince et al. 2009, showed that the post-cure polymerization could start within the 24-h following light curing, but it continued in a slower rate. In this regard, the conclusion was raised, which suggested that the polymerization reaction might not be terminated by the end of the light curing cycle. However, the residual radicals could convert the double bonds over a prolonged time leading to an increase in the DC% (Zissis et al. 2008). As the polymerization reaction progresses, both propagation and termination reactions became of limited diffusion due to the restriction of the pendant groups’ mobility, which occurred via developing a highly cross-linked network polymer, in a process known as auto-deceleration. As a result, some radicals got trapped within the heterogeneous network and can persist for extended periods (Burtscher 1993; Elliott et al. 2001). However, these trapped radicals could encounter pendant groups with time, resulting in additional conversion (Schneider et al. 2006). Moreover, there were other ‘trapped’ active components in the polymer network in addition to the free radicals, such as free monomers, pendant double bonds, and photo-initiators that might have a positive significant effect on the DC% of the resin composites (Leprince et al. 2013). Final conversion might therefore be controlled by diffusion limitations of the reacting groups and not by the amount of the uncured monomers (Lovell et al. 1999). In order to drive small molecules to diffuse into the polymer matrix and make such radicals able to react with any remaining double bonds within the network, studies suggested that inducing a swelling within the matrix of the tested composites by a solvent, which could promote a diffusion reaction and increased the mobility of the system (Leprince et al. 2009, 2010; Truffier-Boutry et al. 2006). Neves et al. (2013), compared the effect of water and ethanol treatments, and they concluded that the reduction of the residual monomer content was found to be higher with ethanol solutions compared to water, which emphasized the effect of the storage media on increasing the diffusion reaction in the stored resin composite. Ethanol act as solvent for resin monomer, and could successfully penetrate the polymer matrix, expanding the space between polymer chains and accelerated water sorption to the polymer matrix. This could promote residual monomer diffusion from the polymer (Fujii et al. 2002). The increased effect of ethanol penetration into the polymer matrix could be attributed to its solubility parameter value which was found to be closer to that of the monomer than that of the water solubility parameter. Correspondingly, the higher proportion of ethanol in the used solution might lead to a more significant reduction of the residual monomer content by diffusion (Neves et al. 2013).

Nevertheless, the results of the current study showed that there was a statistically significant difference between the three storage periods for the FS of the investigated composites. The 24-h revealed the highest mean FS values, while 6-m showing the least statistically significant values (Table 9). The deterioration tendency of FS after storage in alcohol has also been observed in previous studies (Schmidt and Ilie 2012; Drummond et al. 2004; Zhang and Xu 2008), which could be related to the increased solubility of the resin matrix in alcohol. This could enable the solution to penetrate easier into the matrix, thus allowed for greater access to the filler, leading to their leaching and faster deterioration of resin composites (Drummond et al. 2004; Schmidt and Ilie 2012). The FS is much more impaired by more eluted monomers caused by the higher penetration capacity of the alcohol (Zhang and Xu 2008). Moreover, nano-sized fillers have large surface to volume ratio which was observed to increase the water uptake of resin composites (Curtis et al. 2008). This might contribute to the great impact of the alcohol solution. On the other hand, Schwartz and Söderholm (2004) have discussed the possibility that fine filler particles might attribute to a lower plasticizing effect. The low inter-particle spacing present between smaller particles might lead to a reduced diffusion of plasticizing agents (Schwartz and Söderholm 2004). Sideridou et al. (2009) came in disagreement with the results of this study, as they found that storage in ethanol had no impact on the flexure strength of the tested resin composites. Although one of their tested composites was a nanohybrid one, its filler concentration (77 wt%) was lower than the filler concentration of the resin composites used in this study. Another cause for the disagreement was the storage time, which was from 3 to 6 times more than the storage time in the study of Sideridou et al.

Composites with increased cross-link density and low residual monomer have been shown to exhibit a greater wear resistance, hardness, and flexural strength (Ferracane et al. 1997; Ferracane and Greener 1986). Campos et al. (2015), found that ionizing radiation can induce a post cure reaction, which consequently resulted in an increase in both the DC% and FS of resin composites. This was come partly in agreement and partly in disagreement with the results of this study, as radiation exposure did not affect the DC%, while it had a positive significant effect on the FS. The DC% of resin composite system was generally believed to affect the mechanical properties of resin composites (Prasanna et al. 2007; Krämer et al. 2008). There was a common assumption that the higher the conversion of double bonds, the greater the mechanical strength of the resin composites (Lovell et al. 2003). This was not confirmed in the present study, as there was no significant correlation between the DC% of the different resin composites and their FS results (Pearson Correlation = 0.188 and P = 0.76). Variation in the relative amounts of different monomers in the matrix could have a varying effect on the mechanical properties of resin composites (Peutzfeldt 1997). The amount of inorganic filler is a main determinant of FS in the highly filled composite. For this reason, it was reported that to compare the DC% and the FS, the tested resin composites should contain the approximate amount of filler (Lee et al. 2006).

Conclusions

Under the limitations of this study, the following conclusions could be suggested:

  1. 1.

    Radiation exposure had no impact on the final DC% of the investigated resin composites, while it had a positive impact effect on their FS.

  2. 2.

    Resin composites with different filler loadings affected the DC% and FS of the tested resin composites.

  3. 3.

    Storage in ethanol positively influenced the DC%, but it weakened the tested resin composites mechanically, as increasing the storage time in ethanol induced further decreasing in the FS of the tested resin composites.

Nevertheless, it becomes of importance to conduct clinical studies to evaluate the effect of radiation exposure, not only on the soft tissues and teeth, but also on the performance of the existing restorations. This could help clinicians to take the appropriate decision, whether to replace the existing restorations after the exposure to radiation in the head-and-neck region, or try to find a more conservative way, as repair, to treat the failed ones.