Background

Mitochondria are recgonized as the power plants of the cell and the organelles where 90% of ATP are produced (Pizzorno 2014). Since mitochondria are also involved with metabolism, ion homeostasis, and signaling pathways during different stages of the cell cycle, a long list of common diseases such as cancer, diabetes, neurodegenerative and cardiovascular disorders is now believed to be caused by or aggravated by mitochondrial dysfunction (Javadov et al. 2020). However, performing a direct and dynamic evaluation of patients with abnormal mitochondrial functionality remains challenging.

Nuclear imaging can be a powerful tool to overcome such challenge and monitor the metabolic changes in patients with mitochondrial diseases. Among all techniques that have been developed so far, monitoring mitochondrial membrane potential (ΔΨm) with lipophilic, cationic dyes has emerged as one of the most used methodologies (Ehrenberg et al. 1988). Lipophilic cations can penetrate biological membranes by passive diffusion into the cytoplasm and mitochondria due to large negative plasma and mitochondrial membrane potentials (ref.). [99mTc]Tc-Sestamibi, [99mTc]Tc-Tetrofosmin, and [99mTc]Tc-Teboroxime are the only lipophilic cations that have been approved by the FDA for single-photon emission computed tomography (SPECT) imaging (Boschi et al. 2022). However, the clinical use of [99mTc]Tc-Teboroxime has quickly declined in clinical practice due to its rapid myocardial washout (Boschi et al. 2022). To date, only [99mTc]Tc-Sestamibi and [99mTc]Tc-Tetrofosmin are routinely used as myocardial-perfusion as well as tumor imaging agents (Boschi et al. 2022; Schillaci, et al. 2013; Treglia, et al. 2007; Spanu, et al. 2005; Schillaci, et al. 2005).

In addition to SPECT, positron emission tomography (PET) is another popular nuclear imaging techniques for routine clinical practice. Compared to SPECT, PET exhibits superior sensitivity and relatively straight forward imaging quantification process after corrections for photon attenuation and scattering (Rahmim and Zaidi 2008). Following the success of [99mTc]Tc-Sestamibi and [99mTc]Tc-Tetrofosmin, triphenylmethylphosphonium-based PET radiotracers have gradually demonstrated their potentials to monitor mitochondrial functionality through visualizing its membrane potential. 11C-Labeled triphenylmethylphosphonium ([11C]TPMP) is the first triphenylmethylphosphonium-based PET radiotracer and its encouraging outcome for myocardial and tumor imaging has been well recognized (Krause et al. 1994). However, the clinical adaption of [11C]TPMP is hindered by the short half-life of 11C (T1/2: 20 min). As a consequence, 4-[18F]fluorobenzyl-triphenylphosphonium ([18F]FBnTP) (T1/2 of 18F: 109.7 min) has been developed as a next generation of the PET radiotracer to target mitochondrial activity. [18F]FBnTP has shown great promise in various animal models with mitochondrial metabolic disease (Madar et al. 2009, 2011, 2006; Higuchi et al. 2011; Momcilovic et al. 2019) and is currently under a clinical trial (NCT02204462).

Producing radiotracers with highly consistent radiochemical yield and quality is required to bring promising radiotracers from bench to bedside. [18F]FBnTP was originally reported to be synthesized through a four-step, three-pot reaction (Ravert et al. 2004a). Although the overall number of reaction steps was reduced to three (Ravert et al. 2014; Tominaga et al. 2016), such multi-step approach remains a challenge for implementing the radiosynthesis of [18F]FBnTP for routine clinical practices. According to Zhang et al., it is feasible to prepare [18F]FBnTP in one step via a copper‐mediated [18F]fluorination reaction (Zhang et al. 2016). Adopting their encouraging finding and improving upon the process, we report a detailed and highly robust technical protocol to produce the cGMP-compliant radiosynthesis of [18F]FBnTP using GE TRACERlab™ FXFN, the most widely used synthesis module for routine clinical radiopharmaceutical production. The protocol detailed herein greatly simplifies the production process and can be easily followed by anyone skilled in the art and equipped with common resources.

Materials and methods

General

The automated radiosynthesis of [18F]FBnTP via the GE TRACERlab™ FXFN was performed inside the aseptically cleaned COMECER hot cell under cGMP condition. Triphenyl(4‐(4,4,5,5‐tetramethyl‐1,3,2‐dioxaborolan‐2‐yl)benzyl)phosphonium bromide, silver trifluoromethanesulfonate (AgOTf), anhydrous acetonitrile (99.8%), N,N-dimethylformamide (DMF), 1,3-dimethyl-2-imidazolidinone (DMI), potassium carbonate, potassium trifluoromethanesulfonate, and tetrakis(pyridine)copper(II) triflate were purchased from MilliporeSigma (St. Louis, MO). The Alumina N Plus Light Cartridge (Part # WAT023561) and tC18 Plus Short Cartridge (Part # WAT036810) were acquired through Waters (Milford, MA). The ethanol 200 PROOF was obtained from Pharmco. The sterilized water for injection (SWI) and normal saline were the product of Baxter International (Deerfield, IL). All other references of ‘water’ refers to Milli-Q water (18 MΩ•cm) taken from a Millipore Milli-Q Integral 5 water purification system and were primarily used in quality control processes. Anhydrous acetonitrile (99.8%) used in the evaporation step was from MilliporeSigma. Nitrogen and argon gas used primarily in drying and transferring of solutions were provided through Matheson Tri-gas. The automation synthesis on the TRACERlab™ FXFN module was controlled by the TRACERLab FX software.

Synthesis of triphenyl(4‐(4,4,5,5‐tetramethyl‐1,3,2‐dioxaborolan‐2‐yl)benzyl)phosphonium trifluoromethanesulfonate (Fig. 1)

Fig. 1
figure 1

Synthesis scheme of triphenyl(4‐(4,4,5,5‐tetramethyl‐1,3,2‐dioxaborolan‐2‐yl)benzyl)phosphonium trifluoromethanesulfonate

To a solution of triphenyl(4-(4,4,5,5-tetramethyl-1,3,2-dioxaborolan-2-yl)benzyl)phosphonium bromide (1.12 g, 2 mmol) in 12 mL acetonitrile and 12 mL methanol was added AgOTf (0.51 g, 2 mmol) in 3 mL acetonitrile dropwise. The reaction mixture was stirred in the dark for 24 h. The resulted suspension was filtered through celite, and the solid was washed with methanol (2 × 5 mL). The combined filtrate was evaporated to remove volatile solvents. The residue was dissolved in 50 mL dichloromethane and filtered, evaporated under reduced pressure, and lyophilized overnight to obtain the title compound as a white solid (1.25 g, 99%). 1H NMR (300 MHz, CDCl3): δ 7.52 (m, 3H), 7.41–7.27 (m, 15H), 6.67 (dd, J1 = 2.38 Hz, J2 = 8.06 Hz, 2H), 4.79 (d, J = 15.6 Hz, 2H), 1.06 (s, 12H). F NMR (282 MHz, CDCl3): δ − 78.16. MS (ESI+): m/z = 479.4 [M + H]+

Automated synthesis of [18F]FBnTP

Figure 2 illustrates the radiosynthesis scheme of preparing [18F]FBnTP. [18F]Fluoride was produced by irradiating 2.5 mL of enriched [18O]H2O with 60 μAh beam current from the 16.5 MeV GE PETrace cyclotron. The [18F]Fluoride was separated from the [18O]H2O by trapping the [18F]Fluoride on the preconditioned QMA light cartridge. Following the trapping step, 0.8 mL of the solution mixture (H2O/acetonitrile = 1/1) containing 5 mg of potassium triflate and 50 µg of potassium carbonate was used to elute the [18F]fluoride from the cartridge into the reaction vessel. The solution was heated to 120 °C to remove the water and acetonitrile initially. Next, the precursor and catalyst for the reaction, triphenyl(4‐(4,4,5,5‐tetramethyl‐1,3,2‐dioxaborolan‐2‐yl)benzyl)phosphonium trifluoromethanesulfonate and tetrakis(pyridine)copper(II) triflate dissolved in either anhydrous N,N-dimethylformamide or 1,3-dimethyl-2-imidazolidinone, were added to the reaction vessel. The reaction was heated at 110 °C for 10–20 min in a closed reaction vessel to promote the substitution of the 18F for the Bpin leaving group. After the radiolabeling is completed, 2 mL of water was added into the reaction vessel to dilute the reaction mixture. The solution is then passed through a pre-conditioned Alumina N Plus Light cartridge and the eluent is injected to the semi-prep HPLC for purification. Purification was performed using a Phenomenex Luna C18 column (250 mm × 4.6 mm, 5 um) and a mixture of 50% acetonitrile: 50% 50 mM ammonium acetate solution at 5 mL/min. The product fraction was collected and diluted with SWI. This solution was passed through a Sep-Pak Plus Short tC18 cartridge to retain the desired compound followed by a rinse step with SWI to remove excess acetonitrile and ammonium acetate. The final product, [18F]FBnTP was then eluted by 1.0 mL of ethanol and reformulated with 10 mL of saline. The solution was passed through a 0.22 µm vented sterilizing filter into a sterile vial for QC sampling and dose dispensing.

Fig. 2
figure 2

Comparative radiosynthesis scheme of preparing [18F]FBnTP through the original four-step, two-pot reaction and one-step, one-pot reaction performed in this work

Figure 3 illustrates the preparation setup for the radiosynthesis of [18F]FBnTP for injection. Vials 1 through 9 were loaded with the respective reagents shown on Table 1. At position 8, a pre-conditioned QMA cartridge was installed and used as purchased. An Alumina N Plus Light Cartridge was conditioned with 10 mL of water followed by 10 mL of air and connected to the lines at position 9. At position 10, a tC18 Plus Short cartridge that was conditioned with 10 mL of ethanol and 10 mL of water followed by 10 mL of air was installed. The HPLC collection flask containing 50 mL of water was placed at position 11.

Fig. 3
figure 3

Schematic overview of the [18F]FBnTP radiosynthesis on the GE TRACERlab™ FXFN module. The numbers denoted in RED, represented the designation of item and position of reagents and consumables indicated on Table 1

Table 1 Material and reagent list used in the radiosynthesis of [18F]FBnTP via TRACERlab™ FXFN module

Quality control

The characterization of [18F]FBnTP for injection was performed on the Agilent 1260 HPLC system equipped with a variable wavelength detector and Lablogic NaI radio-detector. The analytical method for determining the identity, chemical and radiochemical purity of the [18F]FBnTP include the following conditions: The analytical peak separation flow rate was set to 1.0 mL/min through a Phenomenex Luna C-18(2) column (150 mm × 4.6 mm × 5 μm) and the UV detector @ 254 nm. Mobile Phase (A) Water with 0.01% trifluoroacetic acid and Mobile Phase (B) Acetonitrile with 0.01% trifluoroacetic acid, with isocratic hold at 60% A (2 min) and 40% B. In this condition, [18F]FBnTP was eluted at around 7.5 min.

To determine the working range amount of “cold” FBnTP present in the [18F]FBnTP for injection, HPLC analysis of the reference standard atthe concentration levels of 12.5, 25.0, 50.0, 100.0, 250.0, and 500.0 µg/mL was conducted to establish the “best-fit” calibration curve. Thus, when analyzing [18F]FBnTP product during routine production, the amount of “cold” counterpart was calculated against a single point calibration method using a working reference standard (4 mg of FBnTP standard was dissolved with 10 mL of the HPLC solution), at 20µL injection volume. The residual solvents in [18F]FBnTP for injection was determined by Agilent GC system with FID, equipped with GC Column DB200 (30 m × 0.250 mm, 0.50 µm stationary phase thickness). The system was calibrated to determine the concentration of ethanol, isopropanol, acetonitrile, and 1,3-Dimethyl-2-imidazolidinone. The calibration curve generated from this test were subsequently used for quantification of residual solvents in the validated production batches, The radionuclidic identity and purity, residual Kryptofix® [2.2.2], bacterial endotoxin, sterility. appearance, pH, and filter tests were also performed under the USP < 823 > guidelines.

Results

Automated synthesis of [18F]FBnTP

The production of [18F]FBnTP was able to be completed less than 1 h in the TRACERlab™ FXFN including the trapping of [18F]fluoride from the cyclotron to the QMA cartridge on the synthesizer. The results of [18F]FBnTP synthesis using the TRACERlab are shown in Table 2, in which the fraction between 8.5 and 11.5 min was typically collected during the HPLC purification process (Fig. 4). In an experiment to compare solvent suitability for [18F]FBnTP radiolabeling reaction, we observed that productions with starting activity in range of 37–65 GBq using N,N-dimethylformamide (DMF) as the solvent resulted in the average non-decay-corrected radiochemical yield of 6.18 ± 0.99% with radiochemical purity of 98.34 ± 1.15%. On the other hand, using 1,3-Dimethyl-2-imidazolidinone (DMI) as the reaction solvent greatly improved the 18F labeling efficacy, leading to the much higher radiochemical yield of 28.33 ± 13.92% and radiochemical purity of 99.79 ± 0.41%. The replacement to DMI solvent has also dramatically cut reaction time by half, from 20 to 10 min, which led to the reduction of overall production time to within 55 min. In addition, the apparent molar activity was significantly increased from 7.03 ± 2.11 GBq/µmol to 69.23 ± 45.62 GBq/µmol when switching 1,3-Dimethyl-2-imidazolidinone as the reaction solvent.

Table 2 Radiosynthesis of [18F]FBnTP via TRACERlab™ FXFN module
Fig. 4
figure 4

The chromatography of the [18F]FBnTP production during the HPLC purification process. Purification was performed using a Phenomenex Luna C18 column (250 mm × 4.6 mm, 5 um) and a mixture of 50% acetonitrile: 50% 50 mM ammonium acetate solution at 5 mL/min. The desired product was collected between 8.5 and 11.5 min

Quality control of [18F]FBnTP for injection

The product specifications are listed in Table 3. Figures 5 demonstrated the data results by HPLC analysis for calibration of FBnTP reference standard and Figs. 6 illustrated the data results by GC analysis for calibration of ethanol, isopropanol, acetonitrile, and 1,3-Dimethyl-2-imidazolidinone, respectively. The radiochemical purity and apparent molar activity are described in the previous section. Further HPLC analysis has confirmed that the product remained stable for 8 h post end-of-production (Fig. 7). For GC residual solvents analysis, the observedethanol concentrations ranged between 5 and 9% (v/v), whereas the concentration of acetonitrile, isoproponal, and 1,3-Dimethyl-2-imidazolidinone were negligible (Fig. 8). The pH was between 4.0 and 6.0 and the bubble point was between 70 and 75 psi. In addition, the sterility, pyrogenicity, and all other quality control tests passed specifications based on the USP < 823 > guidelines. Validation data of 3 consecutive [18F]FBnTP production batches are illustrated in Table 3.

Table 3 Product specifications of the 3 consecutive [18F]FBnTP production batches
Fig. 5
figure 5

The calibration curve of FBnTP reference standard by the HPLC analysis

Fig. 6
figure 6

The calibration curve of ethanol, isopropanol, acetonitrile, and 1,3-Dimethyl-2-imidazolidinone by the GC analysis

Fig. 7
figure 7

The HPLC analyses of [18F]FBnTP at the end of synthesis (EOS) and after 8 h of the EOS. No radiolysis was observed, and the product remained stable

Fig. 8
figure 8

The representative GC analyses of [18F]FBnTP at the end of synthesis from a production batch. While the ethanol concentration was found to be 5.65% (v/v) in this batch, isopropanol, acetonitrile and 1,3-dimethyl-2-imidazolidinone were not detected

Discussion

[18F]FBnTP is a promising PET tracer to target negative membrane potential, but its routine application in the clinic is hampered by the complicated multistep radiosynthesis. In this study, a robust synthesis protocol for the multi-dose production of [18F]FBnTP through a one-step, one-pot automated approach was successfully established on the GE TRACERlab™ FXFN radiosynthesizer.

[18F]FBnTP was initially reported to be synthesized through four-step, two-pot reactions that involves fluorination, reduction, bromination, and coupling with triphenylphosphine (Ravert et al. 2004b). A microwave-facilitated synthesis using custom hardware was later reported by the same research group (Ravert et al. 2014), and a relatively simplified three-step, two-pot reactions were further developed (Tominaga et al. 2016). Although the original four-step synthesis has been translated into an automated approach by Waldmann et al. (2018), such strategy remains a challenge for implementing the synthesis of [18F]FBnTP for routine clinical studies as most automated synthetic modules are equipped with only one reactor.

With the advancement of aromatic nucleophilic substitution through copper-mediated fluorination, Zhang et al. revealed the possibility to produce [18F]FBnTP using one-step, one-pot reaction (Zhang et al. 2016). However, the synthesis was performed manually and neither radiochemical yield nor molar activity of the purified product was reported. Resuming this possibility for translation into clinical settings, we have further developed and optimized the automated approach to produce [18F]FBnTP that is cGMP compliant. We initially followed the conditions reported by Zhang et al. (2016) using TRACERlab with higher starting activity (2.59–11.1 GBq). In contrast to the authors’ observation, we found that using tetrakis(pyridine)copper(II) triflate as the catalyst provided a higher radiolabeling efficiency in our automated module, and the formation of tetrakis(pyridine)copper(II) was not as efficiently when copper(II) triflate and pyridine were individually added for reaction. Nevertheless, the radiochemistry yields were still relatively low (6.18 ± 0.99%) and not well suited for radiotracer production on a large scale. Recently, Hoffmann et al. found 1,3-dimethyl-2-imidazolidinone to be an ideal solvent to promote copper-mediated fluorination (Hoffmann et al. 2023). The group systematically evaluated a series of complexes and identified several applicable mediators for highly efficient radiofluorination of aryl boronic and stannyl substrates. Utilization of these mediators in n-butanol/ 1,3-Dimethyl-2-imidazolidinone mixture or 1,3-Dimethyl-2-imidazolidinone alone significantly improved 18F‐labeling yields. In agreement with their findings, we have observed that 1,3-dimethyl-2-imidazolidinone not only significantly improved the radiochemical yield of [18F]FBnTP from 6.18 ± 0.99% to 28.33 ± 13.92%, but also reduced the labeling time from 20 to 10 min. However, in contrast to being able to maintain the higher 18F‐labeling yields using lower precursor amounts by Hoffmann et al., we observed reduced production yields in our case. Compared to the previous reporting of [18F]FBnTP production that requires 90–92 min on the ELIXYS FLEX/CHEM radiosynthesizer (Waldmann et al. 2018), our production time was greatly reduced to within 55 min. More importantly, all commercially available cartridges can be used directly without any modifications in our production process, resulting in an protocol for cGMP manufacturing of [18F]FBnTP for injection.

Conclusions

CGMP-compliant automated radiosynthesis and quality control of [18F]FBnTP have been established on a standard commercially available single reactor synthesizer with high activity concentration, apparent molar activity, and radiochemical purity. While the preclinical and clinical trials using [18F]FBnTP PET are currently underway, the approach reported herein mitigate the clinical adoption of this radiotracer and warrant centralized and large-scale production of [18F]FBnTP.