Background

Aortic stenosis is the most common acquired heart valve disease in the adult and the surgical aortic valve replacement (SAVR) remains the treatment of choice with good outcomes and long-term results [1,2,3,4]. However, patients with comorbidities carry a higher surgical risk and, therefore, they might benefit from recently developed minimally invasive techniques and technologies. Since 2007, the transcatheter aortic valve implantation (TAVI) has become a widely-accepted alternative to open heart surgery in patients with high-risk profiles and, so far, more than 200′000 procedures have already been performed worldwide, mostly with the CoreValve™ (Medronic, Minneapolis, MN) and the SAPIEN™ (Edwards Lifesciences, Irvine, CA) valve families with good hospital and mid-term results [5,6,7,8]. The two arms of the PARTNER trial have proven the safety and efficacy of TAVI in inoperable and high-risk patients with superior results when compared to medical treatment and non-inferior results when compared to standard surgery [7, 8]. Moreover, recently published studies have also shown good valve hemodynamic parameters in early and mid-term follow-ups and in intermediate-risk patients [9,10,11,12,13,14,15].

Alternative access routes have been explored but the two most popular are still the transapical (TA) and the transfemoral (TF): however, patient attribution to these accesses is still questionable in absence of a severe peripheral vascular disease. We compared the outcome of our first 180 consecutive TA and TF TAVI patients and we identified risk factors for postoperative hospital mortality, vascular complications and stroke.

Methods

In the database, we identified the first 90 TA-TAVI cases (TA-group) and the first 90 TF-TAVI cases (TF-group) performed from 2009 to 2014. In our institution, TA-TAVI was performed since 2009 while TF-TAVI were scheduled since 2010. During the same period of time, only few transaortic TAVI have been performed and they are not included in the study.

Clinical variables were prospectively collected in the hospital database and then retrospectively analysed to compare the two groups and to identify risk factors for hospital mortality (30 days mortality or within hospital stay), neurological events (stroke) and vascular complications (major vascular complications including access-site related complications, aortic dissections, aortic root rupture and tamponade due to ventricular rupture) using the VARC-2 definitions described elsewhere [16]. All patients signed informed consents for the index procedure, for the use of clinical data in medical research and for clinical data analysis (Patients included in the Swiss TAVI Registry approved by the Ethics Committee of the Vaud State in Switzerland).

Patients selection criteria

Patients suffering from severe symptomatic aortic valve stenosis with concomitant comorbidities were studied for inclusion in the TAVI program. Standard inclusion criteria for TAVI were used to identify good candidates and the Logistic Euro-SCORE was calculated for all patients to predict hospital mortality. In order to proceed with transcatheter interventions the final decision came from the hospital Heart-Team, in particular concerning patients not fulfilling standard criteria (i.e. younger patients with severe liver disease or patients with porcelain aortas).

Important exclusion criteria for both TA and TF approach were the presence of concomitant severe valvular or coronary disease not suitable for percutaneous procedure, severe left ventricular dysfunction with ejection fraction below 20% and severe patient frailty evaluated by the Heart-Team, which consists of a cardiologist, a surgeon (both coordinators for the TAVI program), an anaesthesiologist, a radiologist and a geriatrician.

An important observation is that during the study period, transapical and transfemoral procedures were not equally distributed (Fig. 1). This was due to the access-site selection process performed by the Heart-Team that embraced, during the years, the launch of new “low-profile” transfemoral devices leading to more valves implanted transfemorally.

Fig. 1
figure 1

Transapical and transfemoral TAVI distribution in our hospital during the study period

All patients enrolled in the TAVI program underwent complementary trans-thoracic echocardiogram, coronary angiogram and three-dimensional cardiovascular computed tomography scan (3D CT-scan) to analyse alternative access routes and to determine the valve size. Peripheral vascular access routes smaller than 6 mm diameter or presenting severe annular calcifications were not considered good access sites for transfemoral TAVR, such as the presence of abdominal aorta aneurysms and vessel tortuosity. In these cases, TA was considered the best option. Pre-dilation of small ilio-femoral arteries was never attempted. The aortic valve annulus was assessed by injected aortic CT-scan and trans-oesophageal echocardiography using the diameter, the area and the perimeter for the stent-valve sizing. Patients with chronic kidney failure underwent CT-scan and coronary angiograms with low-dose of contrast.

Ta-Tavi

TA-TAVI were performed under general anaesthesia through a left antero-lateral mini-thoracotomy at fifth intercostal space. Intraoperative imaging included trans-oesophageal echocardiography to confirm the valve size and fluoroscopy. The apexes were prepared with concentric reinforced purse-string sutures and the devices were the Sapien™ (2009–2010), the Sapien™ XT (2011–2013) and the Sapien™ 3 (2014) valves (Edwards Lifesciences, Irvine, CA). At the beginning of our series, complication-free patients used to be transferred intubated to the intensive care unit while, after getting more experienced, patients were rapidly extubated in the cath-lab and transferred to the intermediate care unit. As previously reported, echo-guided TA-TAVI were performed without contrast injections [17].

Tf-Tavi

Patients with good vascular access underwent TF-TAVI under general anaesthesia. According to our policy, the vascular access was surgically performed with a 3 cm skin incision at the groin in order to puncture the femoral artery under direct vision and prevent collateral damage. Cardiac imaging was similar to TA-TAVI while the devices were the Sapien™ valves, as mentioned above, but also the Medtronic CoreValve™ (Medtronic inc, Minneapolis, MN). All complication-free patients were extubated in the cath-lab and transferred to the intermediate care unit.

Statistical analysis

Statistical analysis was performed using R (version 3.2.2). Continuous variables are summarized as mean ± Standard Deviation and a t-test is used to compare the two groups. Categorical variables are presented as numbers and proportions (%) and a χ2 test or a Fisher exact test is used to compare the two groups. Selected categorical and continuous variables were analysed as risk-factors for hospital mortality (death occurring within 30 days or during the same hospitalization), disabling neurological complications and major vascular complications, using univariate logistic regression. A p-value below 0.05 was considered statistically significant.

Results

Baseline clinical characteristics are described in Tables 1 and 2. Mean age was 80 ± 8.5 and 83 ± 8.4 years, in the TA and TF-group, respectively (p = 0.014), while the sex distribution was similar (50% male patients in the TA-group and 41% in the TF-group, p = 0.231).

Table 1 Demographics, symptoms, risk factors
Table 2 Preoperative imaging and valve hemodynamic

TA-group presented higher prevalence of comorbidities: more vascular disease (TA:79%, TF:22%, p < 0.001), chronic pulmonary disease (TA:32%, TF:10%, p < 0.001), higher prevalence of previously performed vascular surgery (TA:14%, TF:4%, p = 0.039), higher coronary disease (TA:60%, TF:40%, p = 0.007), more previously performed coronary surgery (TA:21%, TF:9%, p = 0.022) and more previously performed cardiac surgery (TA:28%, TF:17%, p = 0.073). Thirteen percent of patients in the TA-group had a porcelain aorta, versus none in the TF-group. More patients with critical preoperative state were included in the TA-group (TA:14%, TF:2%, p = 0.005) and the logistic Euro-SCORE was higher in the TA-group (36 ± 15% for the TA-group compared to 25 ± 4% for the TF-group; p < 0.001).

Successful implantation rate was 100% with longer procedural time in the TF-group (TA:98 ± 33 min, TF:127 ± 56 min, p < 0.001). Twelve patients had redo valve-in-valve for degenerated aortic bioprosthesis, while seven patients received two stent-valves because of a stent-valve malpositioning or migration of the previously implanted stent-valve.

Mean valve size and valve size distribution are listed in Table 3.

Table 3 Procedural data

With regards to hospital mortality and complication, variables were analysed using VARC-2 definitions (Table 4). Mortality for the two groups was similar (TA:9%, TF:10%, p = 0.799) with a learning curve effect at the beginning of our experience. Main cause of death in TA-group was respiratory failure (3%), whereas in the TF-group was disabling stroke (3%). Major vascular complications (including access-related vascular complication, aortic dissection, acute leg ischemia and aortic rupture) occurred more often in the TF-group (TA:3%, TF:11%, p = 0.081) whereas major/life-threatening bleeding (including cardiac tamponade) (TA:3%, TF:4%, p = 1), disabling stroke (TA:2%, TF:3%, p = 1), and bailout valve-in-valve for valve migration or malpositioning (TA:3%, TF:4%, p = 1) were equally distributed (Fig. 2). Re-thoracotomy for bleeding was performed in three TA and a percutaneous pericardial drainage for tamponade was urgently performed in two TF without further surgical exploration. Three patients in TA-group required dialysis.

Table 4 Hospital outcome
Fig. 2
figure 2

Postoperative complications of TA and TF TAVI according to the VARC-2 definitions

As per the onset of new conduction abnormalities leading to pacemaker implantation, five devices were implanted in the TF-group (2 in Sapien™ valves and 3 in CoreValves™) and two in the TA-group (p = 0.444).

Echocardiographic controls showed similar peak (TA:17 ± 9.4 mmHg, TF:18 ± 9.5, mmHg; p = 0.219) and mean transvalvular gradients (TA:9.2 ± 5.1 mmHg, TF:9.7 ± 5.5 mmHg; p = 0.563) in both groups. Mild to severe paravalvular leaks were detected more in TF cases (TA:5%, TF:25%, p < 0.001) (Table 4). Nevertheless, moderate and severe paravalvular leaks were 0% in TA and 3% in TF patients.

Selected variables were analysed as risk factors for hospital mortality (Table 5), major vascular complications (Table 6) and disabling neurological complications according to the VARC-2 definitions (Table 7).

Table 5 Univariate logistical regression analysis for hospital mortality (N:180)
Table 6 Univariate logistical regression analysis for major vascular complications (N:180)
Table 7 Univariate logistical regression analysis for neurological complications (N:180)

Concerning the hospital mortality, some variables were statistically related to a higher risk of death: critical preoperative state (p = 0.026; OR, 4.25; 95% CI, 1.19–15.24), major vascular complications (p = 0.001; OR, 8.07; 95% CI, 2.28–28.53), stent-valve migration (p = 0.014; OR, 21.6; 95% CI, 1.85–252), life-threatening bleeding (p = 0.001; OR, 16.41; 95% CI, 3.31–81.29), disabling stroke (p = 0.003; OR, 17.25; 95% CI, 2.66–112), renal failure (p = 0.022; OR, 10.73; 95% CI, 1.41–81.73), postoperative dialysis (p = 0.014; OR, 21.6; 95% CI, 1.85–252) and need for emergency cardiopulmonary bypass (p = 0.003; OR, 34.71; 95% CI, 3.38–356) (Table 5). Early extubation (defined as extubation within 4 h since the end of the index procedure) represents a protective factor against hospital mortality (p = 0.001; OR, 0.16; 95% CI, 0.05–0.48).

About risk factors for major vascular complications, use of emergency cardiopulmonary bypass was associated with higher rate of vascular injury (p = 0.010; OR, 15; 95% CI, 1.93–116) (Table 6). Concerning risk factors for disabling stroke, postoperative acute renal failure and dialysis were associated with poor neurological outcome (p = 0.035; OR, 14.33; 95% CI, 1.21–169; and p = 0.020; OR, 21.62; 95% CI, 1.61–290, respectively) (Table 7).

Discussion

Since the beginning of transcatheter aortic valve therapies, the two main access routes are the transfemoral and the transapical ones, allowing for placement of balloon-expandable and self-expanding valves of different size. However, the allocation to one of these two access routes is still questionable and based, at the time being, on the presence of a severe vascular disease of the aorta or ilio-femoral vessels, or on the possibility of performing the TF case under sedation [18,19,20,21,22].

In our experience, patients allocated to the two groups (all performed under general anaesthesia) showed different comorbidity patterns: patients in the TA-group presented higher prevalence of comorbidities, higher logistic Euro-SCORE and were more often in a preoperative critical state. Thus, according to the fact that all patients with severe vascular disease were automatically included in the TA-group, we faced a TA population carrying a higher risk profile compared to the TF population. However, the hospital mortality rate and neurological outcome were similar.

Hospital mortality of our first TAVI series is in-line with published preliminary results of TA vs TF showing rates ranges between 5% and 15%, without statistical differences between the groups [18,19,20,21,22]. In a retrospective study, Van der Boon reported hospital mortality of 6.4% for TF and 15.7% for TA whereas in a prospective study including thousand TAVI from Schymik and al. the mortality was 6.5% for TF and 6.1% for TA [19, 21]. Murarka and al. also reported promising mortality rates of 4.5% for TF and 5.3% for TA in a retrospective single-centre experience [22]. However, none of these three aforementioned studies was able to demonstrate a statistically significant difference between the two popular approaches.

In our report, neurological outcome showed similar results for TA and TF (stroke = TA:2%, TF:3%, p = 1) and we didn’t observe a significant difference. Our results are similar to published data. Schymik described 2.3% of stroke in the TF-group and 1.7% in the TA-group with a non-significant p-value between the groups. Other published series show similar conclusions [18,19,20,21,22].

If we consider paravalvular leaks and access-related vascular injuries, we identified a discrepancy in favour for the TA approach. In particular, the mild to severe paravalvular leak incidence (TA:6%, TF:26%, p < 0.001) of our patients was similar to the one published in a retrospective study from Greason and co-workers who reported 12% of mild to severe paravalvular leak in TF versus 8.4% in the TA group [18]. Nevertheless, the incidence of moderate-severe PVL only is low in our groups and almost similar between the two population. Murarka and colleagues as well, have observed similar results between TA and TF with 7.6% of moderate-severe paravalvular leaks in TF-group and 7% in TA-group (p = 0.999) [22]. The reason for some discrepancies in paravalvular leak rate in the 2 techniques can be due to the more direct and more precise valve positioning during TA cases but this is not proved yet. Moreover, as far as paravalvular leaks are concerned, we have to admit that, in our experience, we have seen a great improvement after the launch of last-generation Sapien™ 3 valve featuring an innovative outer skirt preventing leaks. Therefore, we can speculate that, in the future, the use of this valve (or other stent-valves addressing the issue of paravalvular leaks with improved technologies) will reduce the incidence of clinically-relevant leaks.

Regarding the major access-related vascular complication rate in our group, this was higher in TF patients but the result is not statistically significant (TA:3%, TF:11%, p = 0.081). In comparison, if we look at recent publications we can see that the incidence of this complication is more prevalent in TF as well: Schymik reported 17.5% of major vascular complications in TF versus 2.5% in TA (p = <0.0001) [19]. Murarka and colleagues observed similar trend, with 12.1% of major vascular complications in the TF-group versus 0% in the TA-group [22]. New generation devices with low-profile introducer sheaths and small delivery systems will help decreasing the incidence of access site vascular complications in future reports.

As long as the intensive care unit length of stay and extubation time are concerned, in our study these numbers were slightly longer for TA-TAVI patients and this finding is justified by the fact that at the beginning TA patients were all transferred, intubated, to the intensive care unit and then transferred to the intermediate care unit on postoperative day one. On the other hand, since the beginning, complication-free transfemoral TAVI cases were rapidly extubated in the cath-lab and transferred to the intermediate care unit. However, these results are not comparable with other centres as local hospital policies and daily practice can be very different and, sometimes, they can change with acquired experience.

An important point of discussion is the development of new TAVI devices: new generations of stent-valve equipment have more performant designs and low-profile delivery systems assuring lower incidence of paravalvular leak and vascular injury. This development can have a great impact in future reports on TAVI mortality and morbidity allowing for the use of these new devices in mid-risk and younger patients.

Our study presents some limitations. It is a retrospective study describing the hospital outcome of first cases of TA and TF TAVI performed at our Institution with a relatively small number of patients. The population included the preliminary TAVI experience of our hospital and, therefore, a physiologic learning curve can have negatively affected the first-period clinical outcome. The patient-selection process has also changed during the study period as well as the use of new-generation devices.

Conclusion

In conclusion, this study shows our first TAVI experience and results are similar to published data. Based on our findings, we can confirm that transcatheter techniques are promising and provide good hospital outcomes. Improved surgeons’ and cardiologists’ skills and the advent of last-generation devices will facilitate the stent-valve delivery and will help improving the risk of vascular complication, neurological complication and paravalvular leak, also for use in intermediate-risk patients.