Introduction

Periprosthetic joint infection (PJI) is one of the most serious complications after artificial joint replacement (AJR) [1]. Over 98% of PJIs are caused by bacterial species, most of which are Staphylococcus aureus and coagulase-negative staphylococci, which account for 50% to 60% of all PJIs [2, 3]. Notably, a variety of factors, including the surface characteristics of the orthopaedic implant material, can affect bacterial adherence and facilitate infection [4]. Staphylococcus aureus (S. aureus) is the most frequent cause of infection based on implant biomaterials [5, 6].

A number of infections are biofilm-related [7, 8]. A biofilm is an aggregation of surface-associated microbial cells encased in an extracellular polymeric substance (EPS) matrix that provides mechanical stability and resistance to environmental hazards [9, 10]. Furthermore, biofilm bacteria are 100–1000 times less susceptible to antibiotics than planktonic bacteria [11]. It is very challenging to eradicate microbes or mechanically remove biofilms from solid surfaces after the biofilms have grown [12, 13].

Debridement, antibiotics, and implant retention (DAIR) are increasingly used for acute PJIs due to less invasion and lower cost compared to two-stage device exchange. On the other hand, DAIR appears to have a higher failure rate (16–57.4%), and S. aureus PJI appears to have a lower success rate than other organisms [3, 14,15,16].

Studies have shown that many different debridement techniques, such as iodine immersion, pulse lavage (PL), and even mechanical brushing, have been used in vitro to mechanically disrupt and remove the bacterial biofilm established on implant materials [17, 18]. Iodophors are well known as an antiseptic and exhibit extensive activity against various pathogens [19]. It has also been proven that iodophors have potency against fully developed bacterial biofilms in vitro and ex vivo [20, 21]. Combining an iodophor with vancomycin is superior in reducing viable S. aureus cells in immature biofilms grown on titanium surfaces without causing significant cytotoxicity to muscle tissue [22]. Iodophors were found to eliminate bacterial growth on the surface of contaminated polyethylene implants, while hydrogen peroxide failed in one case to completely eradicate growth [23]. Rough cobalt chromium molybdenum (CoCrMo) surfaces are prone to biofilms showing more proteins and polysaccharides, while the effect of iodophor treatment is still unknown [24]. No one has studied the effect of iodophor on biofilm elimination from titanium alloy (TA), cobalt chromium molybdenum (CoCrMo), and polyethylene, which are commonly used materials for artificial joints, and compared the differences in their efficacy.

The literature states that with regard to irrigant efficacy against biofilms, povidone-iodine treatment with the application of 20 ml for 1 min results in greater reductions in nascent MRSA biofilms compared to other solutions [25]. There is also literature that determined the minimum effective exposure time required to prevent the growth of Staphylococcus aureus povidone-iodine 0.35% (Betadine) after 90 s of treatment [26]. The iodophor instructions state that the time of action of skin disinfection at the surgical site is 2 min, the time of action at injection and puncture sites is 2 min, that for disinfection of the hands before surgery is 3 min, and that for disinfection of infected sites is 3 min. We designed a 24-h biofilm infection model and carefully synthesized all the references to determine the iodophor duration of action to be 5 min.

Many studies have shown that the inhibition of biofilms by iodophors was associated with a decrease in transcription of the icaADBC operon, which in turn correlated with the activation of the icaR transcription inhibitor in S. aureus [27,28,29,30]. Bacterial adherence to the target cell is the primary stage of infection. It is determined by fnbA and fnbB (encoding fibronectin-binding proteins A and B), fib (encoding fibrinogen-binding proteins), cna (encoding collagen-binding protein), clfA and clfB (encoding clumping Factors A and B) and eno (encoding laminin-binding protein) [31]. Adherence or attachment ability and biofilm production are important for enhancing virulence factors among isolates of S. aureus [32, 33]. These studies have shown that iodophors can affect the expression of the icaADBC operon and that the virulence and adhesion of S. aureus may also be affected by icaR. clfA, clfB, fnbA, fnbB, etc.

Titanium alloy (TA), cobalt chromium molybdenum (CoCrMo), and polyethylene are commonly used materials for artificial joints. Only one study has investigated the effect of iodophor treatment on biofilm elimination from TA, CoCrMo, and polyethylene materials, but none have investigated the expression of adhesion and virulence-related genes of S. aureus after iodophor treatment. Therefore, we assume that an iodophor acts on the surface of the prosthesis to remove the biofilm and has an effect on the expression of adhesion- and virulence-related genes. In addition, there is the question of whether the effect differs for different implant materials. Therefore, we extended the study to biofilms grown on TA, CoCrMo, and polyethylene coupons and compared the efficacy of eradicating S. aureus biofilms by using an iodophor. Next, we analysed the expression of clfA, icaA, icaB, icaD, and icaR, which are related to the adhesion and virulence of S. aureus. If the treatment can reduce the expression of biofilm adhesion and virulence genes, we will be able to study the molecular mechanism of biofilm elimination, which may lead to therapeutic targets for biofilms. If it can actually remove the biofilm on the surface of the prosthesis, this will significantly improve the success rate of DAIR, which is unquestionably good news for PJI patients.

Materials and methods

Bacterial strain

This study used S. aureus ATCC 25923, provided by the Department of Clinical Laboratory, Jiaxing First Hospital. The strain was grown on tryptic soy agar (TSA; Fushenbio, Shanghai, China) at 37 °C and 5% CO2. Then, representative colonies were picked and suspended in trypticase soy broth (TSB; Fushenbio, Shanghai, China), growing at 37 ℃ overnight with agitation (200 rpm). Bacteria were harvested and resuspended in TSB, adjusted to the turbidity equivalent to 1 McFarland and diluted 1:300, achieving a final cell concentration of approximately 1 × 106 CFU/mL.

Biofilm formation on orthopaedic implants

Titanium alloy (TA), cobalt chromium molybdenum (CoCrMo), and polyethylene materials were made into 10 × 10 × 1 mm smooth coupons (AK Medical Ltd, Beijing, China), washed with an ultrasonic water washing instrument for 30 min before use, and autoclaved after drying. The coupons were placed in 24-well clear bottom microtiter plates (Corning Inc., Corning, NY). Subsequently, 1 mL of bacterial suspension was added to each well and incubated for 24 h at 37 °C and 5% CO2.

Iodophor exposure

After 24 h, the coupons were removed from the bacterial suspension, followed by either (1) exposure to 0.5 ± 0.05% iodophor (Health Essence, Beijing, China) for 5 min or (2) exposure to phosphate buffered saline (PBS; Solarbio, Beijing, China) for 5 min. Experiments were performed in triplicate.

Viable cell count

Each coupon was rinsed with sterile PBS after being exposed to the treatment arms. The rinsed coupon was placed in a 15-mL tube containing 10 mL of PBS. By applying a 35 kHz sonication frequency to 10 mL of PBS for 15 min, the biofilm was eliminated in 10 mL of PBS. A 10-s vortex interval was added between each of the three times sonication was performed. A total of 10 serial dilutions were made and plated onto TSA, which was then incubated for 24 h at 37 °C with 5% CO2. The number of CFUs, represented as CFU/cm2 was then determined.

Biofilm assays

The wells were treated for 5 min with iodophor and PBS, and after that, all of the bacteria in the basal state were eradicated by giving the wells two rounds of PBS rinsing. To stain the biofilm, 1 mL of 0.1% crystal violet staining solution (Beyotime, Shanghai, China) was applied to each well after the plates were dried at 37 °C. At room temperature, the plates were incubated for 15 min. After the stain was removed, the plates were flushed three times with PBS and then dried at 37 °C. One millilitre of 95% ethanol was used to dissolve the biofilm. Using a microplate reader (ELX800, Bio-Tek, USA), the absorbance was measured at a wavelength of λ = 570 nm after 15 min of incubation.

Confocal laser scanning microscopy (CLSM)

Confocal laser scanning microscopy (CLSM, LSM800, Zeiss, Germany) was used in the control group and treatment group to image the bacterial biofilms and confirm the CFU data. The bacterial biofilms were observed using a SYTO-9/PI Live/Dead Bacterial Double Stain Kit (Fushenbio, Shanghai, China) following the manufacturer’s instructions. The Live-Dead kit contains SYTO-9, which stains viable bacterial DNA green, and dead cells appear red when propidium iodide (PI) enters compromised bacterial cell membranes. After exposure to the treatments, the coupons were lightly dipped in sterile water three times to remove nonfirmly attached bacteria and debris. Then, after staining for 15 min at room temperature in the dark, the biofilms were rinsed with PBS to remove the extracellular dyes and observed with CLSM.

Determination of gene expression by quantitative real-time PCR (q-PCR)

Ribonucleic acid (RNA) isolation

The bacterial culture was centrifuged (5 min, 6000 RCF) after 24 h of incubation. Total RNA was subsequently isolated using a Bacteria Total RNA Isolation Kit (Sangon Biotech, Shanghai, China) according to the manufacturer’s protocol following a 5–10 min pretreatment of the cells with 50 mg of lysostaphin.

(Sangon Biotech, Shanghai, China) in 100 mL of 50 mM EDTA. Purified RNA was eluted with DNase/RNase-Free Water (Beyotime, Shanghai, China), and the integrity of the RNA was confirmed by 1% agarose gel electrophoresis. RNA quantity and purity were determined by a Microvolume UV‒Vis Spectrophotometer (NanoDrop One, Thermo Fisher Scientific, USA).

Reverse transcription

The reverse transcription reaction was performed using 5 × PrimeScript™ RT Master Mix (Perfect Real Time) (Takara Biomedical Technology, Beijing, China).

The reaction mixture (20 μL) contained is given in Table 1.

Table 1 Components for reverse transcription

After gentle mixing, reverse transcription was carried out under the following conditions: 37 °C for 15 min and 85 °C for 5 s.

Q-PCR

q-PCR was performed to detect the five genes related to biofilm formation capacity, clfA, icaA, icaB, icaD, and icaR, and the 16S reference gene (Table 2).

Table 2 Gene sequences for real-time PCR

For this purpose, PowerUp™ SYBR™ Green Master Mix (Thermo Fisher Scientific, USA) was used, following the manufacturer’s recommended protocol. The reaction mixture (20 μL) contained is given in Table 3.

Table 3 Components for real-time PCR

Run the program as follows (Tables 4, 5).

Table 4 Standard cycling mode for real-time PCR
Table 5 Melt curve stage procedure for real-time PCR

Statistical analysis

GraphPad Prism 5 software (GraphPad Prism Software, Inc.; San Diego, CA, USA) was used for statistical analysis. A two-tailed, unpaired Student's t test with equal variance was used. If p < 0.01, statistical significance was determined.

Results

Viable cell count

The number of CFUs on the coupons was used to quantify the bacteria. After 24 h, the viable cell count in the control group had grown to approximately 1010 CFU/cm2 (Fig. 1). The treatment group showed an approximate three-log reduction in CFU/cm2 compared to the control group (p < 0.001). However, there was not much difference between the CoCrMo coupons and TA coupons in the reduction of CFUs, and the polyethylene showed less reduction than the two orthopaedic implant materials.

Fig. 1
figure 1

The biofilm cell density was measured after treatment, revealing a decrease in biofilm mass. TA titanium alloy, CoCrMo cobalt chromium molybdenum. *** represent P ≤ 0.001, and there is a statistically significant difference between the two sets of data when P ≤ 0.001

Determination of antibiofilm activity

Biofilms formed by Staphylococcus aureus on the surface of different orthopaedic implant materials were quantified using crystal violet staining. The absorbance count represented the amount of biofilm formed. The amount of Staphylococcus aureus biofilm on the polyethylene surface was the largest, followed by that on CoCrMo and TA. After treatment, the absorbance of the biofilms was significantly reduced compared to that of the control group (p < 0.001). CoCrMo had the lowest absorbance values, while the other two materials had similar absorbance values. Polyethylene had the largest reduction in absorbance, followed by CoCrMo and TA (Additional file 1) (Fig. 2).

Fig. 2
figure 2

The biofilm absorbance was measured by a microplate reader, indicating a decrease in the amount of biofilm. TA titanium alloy, CoCrMo cobalt chromium molybdenum. *** represents P ≤ 0.001, and there is a statistically significant difference between the two sets of data when P ≤ 0.001

Live/dead backlight staining by confocal microscopy

Confocal microscopy was a useful method for measuring the level of biofilm debridement after exposure to the iodophor for 5 min or PBS for 5 min (Fig. 3). After exposure to the iodophor for 5 min, the luminescence of the artificial prosthesis materials was reduced. This means that the biofilm cell density and viability had been reduced. Polyethylene showed less green staining due to light transmission than CoCrMo coupons and TA coupons, either for 5 min of iodophor treatment or PBS (Additional file 2).

Fig. 3
figure 3

Confocal laser scanning microscopic images showing biofilm formation. (A: cobalt chromium molybdenum (CoCrMo) coupons exposed to the iodophor for 5 min; B: titanium alloy (TA) coupons exposed to the iodophor for 5 min; C: polyethylene coupons exposed to the iodophor for 5 min; D: cobalt chromium molybdenum (CoCrMo) coupons exposed to PBS for 5 min; E: titanium alloy (TA) coupons exposed to PBS for 5 min; F: polyethylene coupons exposed to PBS for 5 min.) Live cells are stained green, and dead cells are stained red. The scale bar represents 100 μm magnification. G-I: Scanning electron microscopy (SEM, FEI Inspect F50, ThermoFisher, USA) images to describe the surface characterization of materials. (G: cobalt chromium molybdenum (CoCrMo) coupons; H: titanium alloy (TA) coupons; I: polyethylene coupons.) Scale bars represent 100 μm and 1 μm magnification respectively

Determination of gene expression by real-time PCR

Using real-time PCR, the levels of relative gene expression were measured to determine whether the reduced ability to build biofilms in the presence of the iodophor was associated with altered expression of the icaABDR and clfA loci. Consistent with the reduction in biofilm, icaABDR expression is reduced on three artificial joint materials and clfA expression is also inhibited on titanium alloy coupons exposed to the iodophor (Additional file 1). The results are statistically significant (p ≤ 0.01) (Fig. 4).

Fig. 4
figure 4

Comparative measurement of clfA, icaA, icaB, icaD and icaR transcription in the S. aureus ATCC 25923 strain. TA titanium alloy, CoCrMo cobalt chromium molybdenum. Ns, ** and *** represent P > 0.05, P ≤ 0.01, P ≤ 0.001, and there is a statistically significant difference between the two sets of data when P ≤ 0.01

Discussion

The development of biofilms and bacterial proliferation causes an implant infection that is resistant to treatment [34]. There is an urgent need for an efficient method to remove bacterial biofilms from implants due to the significant risks of infection that could develop during the perioperative period [35]. The primary method of treating acute periprosthetic infection is surgical debridement in conjunction with certain antibiotics. For the clinical diagnosis and management of periprosthetic infections, research on the antibacterial properties of iodophors on various orthopaedic implant materials is beneficial.

In vitro, the scavenging effect of some disinfectants on biofilms has been studied. A high concentration of farnesol (30 mM) shows antimicrobial properties against bacterial biofilms [36, 37]. Hypochlorous acid, a powerful disinfectant, can break bacterial biofilms and may be useful in the treatment of orthopaedic fixative infections [38]. Hydrogen peroxide also has the same effect [39]. These results indicate that disinfectants can remove biofilms. Iodophors are also effective in removing biofilms, which supports our research [26, 27, 40].

This is the first study of the effect of iodophors on biofilm clearance from artificial joint materials. Our study revealed that the number of S. aureus organisms and the number of biofilms on the surface of TA, CoCrMo, and polyethylene coupons decreased significantly after 5 min of iodophor treatment, and the number of plate counts decreased from 1010 to 107. Several studies have shown that iodine-supported titanium implants can inhibit biofilm formation [41, 42]. Polyethylene joint prostheses are prone to infection and wear [43]. Rough cobalt chromium molybdenum (CoCrMo) surfaces are prone to biofilms showing more proteins and polysaccharides, while the effect of iodophor treatment is still unknown [24]. Perhaps the addition of iodine coatings to the other two materials will make the biofilm removal effective.

Grossman quantified S. aureus biofilm formation by crystal violet and confocal microscopy, which is a classic and standardized approach [44]. We used the same methodology for our research. After iodophor treatment, the number of biofilms in CoCrMo coupons was the lowest, followed by the TA coupons and the polyethylene coupons. Before treatment, the TA coupons had the lowest number of biofilms, followed by the CoCrMo coupons, and the polyethylene coupons had the highest. Regardless of whether the polyethylene coupon was treated, its biofilm adherence was greatest.

The results of live/dead backlight staining by confocal microscopy revealed a large number of viable bacteria (green light) on the surface of the three orthopaedic implant materials in the PBS treatment group. Comparatively, the number of viable bacteria on the surface of the three materials in the iodophor treatment group was significantly reduced to only a small number, and there were few dead bacteria (red light). Moreover, polyethylene coupons showed less fluorescence due to light transmission than the other two coupons.

PI was shown to significantly inhibit the formation of bacterial biofilms and reduce the expression of the hla, ebps, eno, fib, icaA, and icaD genes [40]. The results for icaA and icaD are consistent with ours. Our data revealed that in addition to its known antibacterial properties, iodophors can also inhibit S. aureus biofilm development at least in part by repressing the transcription of icaABDR, and the transcription of clfA was inhibited on titanium alloy coupons. Oduwole and Barakat's articles also confirmed this finding [30, 39]. The expression of the 5 genes had different inhibitory effects on different materials.

However, our study was limited in some ways. First, we did not evaluate modifications to the implant surface, such as surface roughness, which has a significant impact on implant longevity [45, 46]. And surface roughness also affects the total surface area which in turn can influence biofilms formation. Second, it may not apply to other types of bacteria, such as methicillin-resistant Staphylococcus aureus (MRSA), as we used only one strain experiment model. Third, the optimal action time and concentration of iodophors need to be further experimentally explored. More rigorous animal experiments and large-sample, multicentre, randomized controlled clinical trials are also needed, which will be carried out in the future.

In addition, it should be noted that the PCR technique may be insufficient to determine the genetic basis of biofilm production because the presence or absence of a gene does not directly indicate that the encoded protein plays a role in the ability of the staphylococci to form a biofilm in the first place. Therefore, future research should also focus on the use of advanced molecular biology techniques to gain a better understanding of the genetic basis of adhesion and virulence capacity in the Staphylococcus genus.

Conclusion

This is the first study to explore the inhibition of S. aureus biofilms and the expression of genes related to adhesion and virulence when artificial joint replacement materials (titanium alloy, cobalt chromium molybdenum, polyethylene) are exposed to the iodophor. An in vitro study showed that artificial joint materials with adherent S. aureus showed significant elimination of biofilms when exposed to an iodophor for 5 min, and the expression of icaACDR was significantly reduced. Moreover, iodophor-treated titanium alloys reduced the expression of clfA. This provides strong evidence for using iodophors clinically to treat periprosthetic joint infections without removing the artificial joints. More experimental and in vivo studies are needed to support this hypothesis in the future.