The long-term stability of the counting and spectrometric characteristics of a fused silica proportional counter has been investigated to assess its applicability to search for an admixture of sterile neutrinos. The results of continuous measurements of the K-peak position in the spectrum of deposited energies from decay of 37Ar traces in a counter filled with CO2 are presented. It is shown that the gas amplification remained stable within 0.1% during 1 month of continuous measurements at an initial isotope activity of approximately 100 Bq. This estimate of the stability of a fused silica counter is 5 times better than the values published earlier.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.

Similar content being viewed by others

REFERENCES

  1. Abdurashitov, D.N., Berlev, A.I., Likhovid, N.A., Lokhov, A.V., Tkachev, I.I., and Yants, V.E., Phys. At. Nucl., 2015, vol. 78, no. 2, p. 268. https://doi.org/10.1134/S1063778815020027

    Article  Google Scholar 

  2. Abdurashitov, D.N., Malyshkin, Yu.M., Matushko, V.L., and Suerfu, B., Nucl. Instrum. Methods Phys. Res., Sect. B, 2016, vol. 373, p. 5. https://doi.org/10.1016/j.nimb.2016.02.029

    Google Scholar 

  3. Kuz’minov, V.V., Likhovid, N.A., and Novikov, V.M., Prib. Tekh. Eksp., 1990, no. 4, p. 86.

  4. Danshin, S., Kopylov, A., and Yants, V., Nucl. Instrum. Methods Phys. Res., Sect. A, 1994, vol. 349, nos. 2–3, p. 466. https://doi.org/10.1016/0168-9002(94)91212-2

    Google Scholar 

  5. Abdurashitov, J.N., Gavrin, V.N., Girin, S.V., Gorbachev, V.V., Gurkina, P.P., Ibragimova, T.V., Kalikhov, A.V., Khairnasov, N.G., Knodel, T.V., Matveev, V.A., Mirmov, I.N., Shikhin, A.A., Veretenkin, E.P., Vermul, V.M., Yants, V.E., et al., Phys. Rev. C: Nucl. Phys., 2006, vol. 73, p. 045805. https://doi.org/10.1103/PhysRevC.73.045805

    Article  ADS  Google Scholar 

  6. Browne, E. and Firestone, R.B., Table of Radioactive Isotopes, New York: Wiley, 1986.

    Google Scholar 

  7. Endt, P.M., Nucl. Phys. A, 1990, vol. 521, p. 1. https://doi.org/10.1016/0375-9474(90)90598-G

    Article  ADS  Google Scholar 

  8. http://www.gnu.org/software/octave.

  9. Blum, W., Riegler, W., and Rolandi, L., Particles Detection with Drift Chambers, Berlin, Heidelberg: Springer, 2008.

    Google Scholar 

Download references

ACKNOWLEDGMENTS

We are grateful to T. Chuvil’skaya, V. Yantz, and S. Zadorozhnyi for the opportunity and assistance in conducting the measurements. We also thank I. Tkachev, V. Pantuev, and A. Nozik for the fruitful discussion and constructive criticism of the experimental results. This work was supported by the Russian Foundation for Basic Research (grant no. 17-02-00361-a).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to D. N. Abdurashitov.

Additional information

Translated by N. Goryacheva

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Abdurashitov, D.N., Chernov, V.G. The Long-Term Stability of a Fused-Silica Proportional Counter. Instrum Exp Tech 62, 5–9 (2019). https://doi.org/10.1134/S0020441218060143

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0020441218060143

Navigation