Abstract
The long-term stability of the counting and spectrometric characteristics of a fused silica proportional counter has been investigated to assess its applicability to search for an admixture of sterile neutrinos. The results of continuous measurements of the K-peak position in the spectrum of deposited energies from decay of 37Ar traces in a counter filled with CO2 are presented. It is shown that the gas amplification remained stable within 0.1% during 1 month of continuous measurements at an initial isotope activity of approximately 100 Bq. This estimate of the stability of a fused silica counter is 5 times better than the values published earlier.
Similar content being viewed by others
REFERENCES
Abdurashitov, D.N., Berlev, A.I., Likhovid, N.A., Lokhov, A.V., Tkachev, I.I., and Yants, V.E., Phys. At. Nucl., 2015, vol. 78, no. 2, p. 268. https://doi.org/10.1134/S1063778815020027
Abdurashitov, D.N., Malyshkin, Yu.M., Matushko, V.L., and Suerfu, B., Nucl. Instrum. Methods Phys. Res., Sect. B, 2016, vol. 373, p. 5. https://doi.org/10.1016/j.nimb.2016.02.029
Kuz’minov, V.V., Likhovid, N.A., and Novikov, V.M., Prib. Tekh. Eksp., 1990, no. 4, p. 86.
Danshin, S., Kopylov, A., and Yants, V., Nucl. Instrum. Methods Phys. Res., Sect. A, 1994, vol. 349, nos. 2–3, p. 466. https://doi.org/10.1016/0168-9002(94)91212-2
Abdurashitov, J.N., Gavrin, V.N., Girin, S.V., Gorbachev, V.V., Gurkina, P.P., Ibragimova, T.V., Kalikhov, A.V., Khairnasov, N.G., Knodel, T.V., Matveev, V.A., Mirmov, I.N., Shikhin, A.A., Veretenkin, E.P., Vermul, V.M., Yants, V.E., et al., Phys. Rev. C: Nucl. Phys., 2006, vol. 73, p. 045805. https://doi.org/10.1103/PhysRevC.73.045805
Browne, E. and Firestone, R.B., Table of Radioactive Isotopes, New York: Wiley, 1986.
Endt, P.M., Nucl. Phys. A, 1990, vol. 521, p. 1. https://doi.org/10.1016/0375-9474(90)90598-G
http://www.gnu.org/software/octave.
Blum, W., Riegler, W., and Rolandi, L., Particles Detection with Drift Chambers, Berlin, Heidelberg: Springer, 2008.
ACKNOWLEDGMENTS
We are grateful to T. Chuvil’skaya, V. Yantz, and S. Zadorozhnyi for the opportunity and assistance in conducting the measurements. We also thank I. Tkachev, V. Pantuev, and A. Nozik for the fruitful discussion and constructive criticism of the experimental results. This work was supported by the Russian Foundation for Basic Research (grant no. 17-02-00361-a).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated by N. Goryacheva
Rights and permissions
About this article
Cite this article
Abdurashitov, D.N., Chernov, V.G. The Long-Term Stability of a Fused-Silica Proportional Counter. Instrum Exp Tech 62, 5–9 (2019). https://doi.org/10.1134/S0020441218060143
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S0020441218060143