Abstract
The parameters of detectors based on CdZnTe crystals with a sensitive volume of approximately 1500 mm3 are investigated. It is shown that at room temperature the characteristics of these detectors are high enough for spectrometry of γ rays from 241Am, 57Co, 137Cs, and 60Co sources.
Similar content being viewed by others
References
Bavdaz, M., Peacock, A., and Owens, A., Nucl. Instrum. Methods Phys. Res., A, 2001, vol. 458, nos. 1−2, p. 123. https://doi.org/10.1016/S0168-9002(00)01033-0
Devanathan, R., Corrales, L.R., Gao, F., and Weber, W.J., Nucl. Instrum. Methods Phys. Res., A, 2006, vol. 565, no. 2, p. 637. https://doi.org/10.1016/j.nima.2006. 05.085
Owens, A., Bavdaz, M., Andersson, H., Gagliardi, T., Krumrey, M., Nenonen, S., Peacock, A., Taylor, I., and Tröger, L., Nucl. Instrum. Methods Phys. Res., A, 2002, vol. 484, nos. 1–3, p. 242. https://doi.org/10.1016/S0168-9002(01)01956-8
Shorohov, M., Tsirkunova, I., Loupilov, A.V., Budtz-Jorgensen, C., and Kuvvetli, I., Nucl. Instrum. Methods Phys. Res., A, 2007, vol. 576, no. 1, p. 80. https://doi.org/10.1016/j.nima.2007.01.124
Niraula, M., Nakamura, A., Aoki, T., Tomita, Y., and Hatanaka, Y., Nucl. Instrum. Methods Phys. Res., A, 2002, vol. 491, nos. 1–2, p. 168. https://doi.org/10.1016/S0168-9002(02)01175-0
Sordo, S.D., Abbene, L., Caroli, E., Mancini, A.M., Zappettini, A., and Ubertini, P., Sensors, 2009, vol. 9, no. 5, p. 3491. doi doi 10.3390/s90503491
Dorogov, P., Ivanov, V., Loutchanski, A., Grigorjeva, L., and Milles, D., IEEE Trans. Nucl. Sci., 2012, vol. 59, no. 5, p. 2375. doi 10.1109/TNS.2012.2212460
http://bsi.lv/en/products/czt-cdte-detectors-andassociate/
Sowinska, S.M., Hennard, G., Feder, D., Hage-Ali, M., Koebel, J.M., Zumbiehl, A., Ayoub, M., and Siffert, P., IEEE Trans. Nucl. Sci., 2002, vol. 49, no. 6, p. 3306. doi 10.1109/TNS.2002.806239
Bolotnikov, E., Abdul-Jabbar, N.M., Babalola, S., Camarda, G.S., Cui, Y., Hossain, A., Jackson, E., Jackson, H., James, J.R., Luryi, A.L., and James, R. B., Proc. SPIE, 2007, vol. 6706, p. 670603.
Bolotnikov, A.E., Camarda, G.C., Carini, G.A., Fiederle, M., Li, L., McGregor, D.S., McNeil, W., Wright, G.W., and James, R.B., IEEE Trans. Nucl. Sci., 2006, vol. 53, no. 2, p. 607. doi 10.1109/TNS.2006. 871509
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © V.B. Brudanin, Yu.B. Gurov, S.V. Rozov, V.G. Sandukovsky, E.A. Yakushev, 2018, published in Pribory i Tekhnika Eksperimenta, 2018, No. 1, pp. 13–16.