Abstract
Results of the analysis and upgrading of the high-voltage pulse generator circuit in the proton injector for operation with a 100-Hz pulse repetition rate are presented.
Similar content being viewed by others
References
Belov, A.C., Frolov, O.T., Nikulin, E.S., Yakushev, V.P., and Zubets, V.N., Proc. RUPAC-2012, St. Petersburg, Russia. 2012 http://accelconfwebcernch/AccelConf/ rupac2012/papers/tuppb036pdf
Feschenko, A.V., Kvasha, A.I., and Serov, V.L., Probl. At. Sci. Technol., Ser. Nucl. Phys. Invest., 2014, no. 3, p. 32.
Drugakov, A.N., Feschenko, A.V., Kvasha, A.I., Naboka, A.N., and Serov, V.L., Proc. RUPAC-2012, St. Petersburg, Russia, 2012. http://accelconfweb. cernch /AccelConf/rupac2012/papers/ moppa023
Derbilov, V.I., Esin, S.K., Nikulin, E.S., Frolov, O.T., and Yakushev, V.P., Probl. At. Sci. Technol., Ser. Nucl. Phys. Invest., 2004, no. 1, p. 13.
Belov, Yu.V., Gryzlov, A.I., Malyshev, I.F., Zvontsov, A.G., Torgovanov, E.I., Esin, S.K., Kolobanov, E.I., and Yakushev, V.P., Trudy VIII Vsesoyuznogo soveshchaniya po uskoritelyam zaryazhennykh chastits (Proc. 8th All-Union Meeting on Charged Particle Accelerators), Dubna: OIYaI, 1983, vol. 2, p. 159.
Zubets, V.N., Derbilov, V.I., Esin, S.K., Klenov, V.S., Nikulin, E.S., Frolov, O.T., and Yakushev, V.P., Probl. At. Sci. Technol., Ser. Nucl. Phys. Invest., 1999, no. 4, p. 38.
Zubets, V.N., Derbilov, V.I., Esin, S.K., Nikulin, E.S., Frolov, O.T., and Yakushev, V.P., Trudy XIII Mezhdunarodnoi konferentsii po elektrostaticheskim uskoritelyam (Proc. 13th Int. Conf. on Electrostatic Accelerators), Obninsk, 2000, GNTs RF FEI, p. 174.
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © A.S. Belov, V.N. Zubets, L.P. Nechaeva, E.S. Nikulin, A.V. Turbabin, O.T. Frolov, 2016, published in Pribory i Tekhnika Eksperimenta, 2016, No. 2, pp. 48–53.
Rights and permissions
About this article
Cite this article
Belov, A.S., Zubets, V.N., Nechaeva, L.P. et al. Operation mode of the proton injector in the linac of the Institute for Nuclear Research with a 100-Hz pulse repetition rate. Instrum Exp Tech 59, 203–208 (2016). https://doi.org/10.1134/S0020441216020032