Abstract
Many clinical studies have shown a satisfactory clinical efficacy using bone cement-augmented pedicle screw in osteoporotic spine, however, few studies have involved the application of this type of screw in lumbar spondylolisthesis. This study aims to investigate the mid-term clinical outcome of bone cement-injectable cannulated pedicle screw (CICPS) in lumbar spondylolisthesis with osteoporosis. From 2011 to 2015, twenty-three patients with transforminal lumbar interbody fusion (TLIF) using CICPS for lumbar spondylolisthesis were enrolled in the study. Oswestry Disability Index (ODI) and Visual Analogue Scale (VAS) were used to evaluate faunctional recovery and physical pain; and operation time, blood loss and hospitalization time were recorded, respectively. Radiograph and computed tomography of lumbar spine was performed to assess loss of the intervertebral disc space height, fixation loosening, and the rate of bony fusion. The average follow-up time of 23 patients was 22.5 ± 10.2 months (range, 6–36 months). According to VAS and ODI scores, postoperative pain sensation and activity function were significantly improved (p < 0.05). The height of the intervertebral disc space was reduced by 0.4 ± 1.1 mm, and the bone graft fusion rate was 100%. No cases of internal fixation loosening or screw pullout was observed. CICPS using cement augmentation may suggest as a feasible surgical technique in osteoporotic patients with lumbar spondylolisthesis.
Similar content being viewed by others
Introduction
Lumbar spondylolisthesis is a common clinical spine disease. In elderly osteoporosis spine, the anti-pullout force of the pedicle screws is significantly inadequate owing to the poor bone quality. Intraoperative and postoperative screw loosening and other types of failure occurs frequently1. Screw failure during the operation leads to difficulties in vertebral body reduction, especially in lumbar spondylolisthesis. To solve this problem, operative segment needs to be extended or screw path augmentation needs to be carried out, which leads to the increase of operation time. However, the effect after augmentation is not accurate, screw failure may reoccur. Bony fusion failure observe during the postoperative rehabilitation process ultimately, which causes symptoms such as osphyalgia and sciatica. Therefore, improving the stability of internal fixation and increasing the bony fusion rate in lumbar spondylolisthesis with osteoporosis have always been the challenges facing spine surgeons.
Traditional methods to improve the stability of pedicle screw are as follows: (1) Increasing the length and diameter of the screws2; (2) Improving the screw design, such as expansion screw3,4; and (3) Using bone granules or bone cement such as polymethylmethacrylate (PMMA) to strengthen the screw tunnel5,6,7. Due to the poor bone quality in osteoporosis spine, most of the methods are not effective. Although PMMA augmentation is considered a reliable and feasible method up to the present time. However, screw tunnel augmentation with PMMA is a complicated procedure, which may also increase the operation time, the amount of bleeding and the risk of PMMA leakage (approximately 30%)8. Surgeons showed great anxiety about internal fixation failure especially in the treatment of lumbar spondylolisthesis with osteoporosis. Figure 1 shows a typical case of postoperative screw loosening in this condition. To overcome this problem, authors improved the design and created a new type of hollow cement-augmented pedicle screw (CAPS) named bone cement-injectable cannulated pedicle screw (CICPS).
To evaluate the results and feasibility of this technique, we retrospectively reviewed the data of 23 consecutive patients with lumbar spondylolisthesis treated with TLIF using CICPS, and summarized the incidence of complications and the clinical efficacy of PMMA augmentation.
Materials and Methods
Clinical data
CICPS design
CICPS was designed as a hollow screw rod with three side holes for bone cement outflow at the tip. The side holes were arranged from small to large. In this manner, bone cement could flow out of the side holes evenly to achieve a “Root”-like riveting strengthening effect. Less bone cement usage is needed in CICPS, which get benefit from the special side hole design. In refs. 10,11, we have described the design features of CICPS in detail.
General data
From 2011 to 2015, consecutive 23 patients compriseing 9 males and 14 females with lumbar spondylolisthesis and osteoporosis were reviewed in the study. The average age at the time of surgery was 63.3 ± 7.8 years (rang, 56–79 y). Inclusion criteria were as follows: 1. Patient age >60 years; 2. Single level lumbar spondylolisthesis (X-ray); 3. T-score <−2.5 SD on dual-energy x-ray absorptiometry9; and 4. No surgical contraindications. Exclusion criteria were as follows: 1.Allergy to the implant; 2. Normal bone mineral density (BMD); 3. Presence of other spine diseases; and 4. Infections, blood system-related diseases, or other surgical contraindications. Osteoporosis was graded according to the Jikei grading scale. There were 13 cases with level II and 10 cases with level III10. According to the Meyerding classification of spondylolysis11, 10 cases had degree I, 9 cases had degree II, and 4 cases had degree III. General information of patients is presented in Table 1. The study was approved by the Daping Hospital ethics committee (IRB, 2019149). All methods were performed in accordance with the relevant guidelines and regulations. And all patients included in this study gave their informed consent.
Surgical method
TLIF or mis-TLIF was routinely performed. The screws were placed manually according to the anatomical landmarks. The angle of the CICPS was slightly larger than that of the conventional pedicle screw, which could reduced the risk of bone cement leakage12,13. Inaddition, the following attentions were taken to ensure the augmentation effect and further reduce bone cement leakage risk: 1. CICPS suggested to keep parallel to the upper and lower endplates in the process of screwing; 2. The probe was used to detect the required screw length so that the outflow side holes was located in the anterior 2/5th of the vertebral body; and 3. CICPS was not allowed to penetrate the the pedicle wall and the lateral cortex of the vertebral body. In principle, we recommended a minimum number of CICPSs should be used13, because the revision might be very difficult. In this group, when manual findings during tapping indicated that the fixation stability might be insufficient, CICPS augmentation was used. The remaining screws adopted conventional ones.
PMMA powder and water agent were mixed together, and then, they were inserted into a special bone cement syringe. During the period of a dough-like mass viscosity, 1–2 ml of PMMA mixture was injected into the vertebral body through a special connecting device. The whole injection procedure was controlled by a C-arm machine; if PMMA leakage was observed, stop injecting immediately. A universal or single-axis screw head was adopted according to the requirements of installing rods. After the PMMA cement had completely hardened, rods were installed; and nuts were locked to reposition the slipped vertebral body. Then, routine spinal canal decompression and bone graft fusion were performed.
Postoperative treatment
In this study, antibiotics were routinely used to prevent surgical site infection in the first 48 hours. Cardiopulmonary rehabilitation training in bed was allowed in the first 24 hours, and the suction drain should be removed within 3 days when the amount of drainage fluid was less than 50 ml. Three days after surgery, the patients was encouraged to get out of bed under the protection of thoracolumbar brace. The patients needed to bear the thoracolumbar brace continuously until 3 months after operation.
Evaluation method
The operation data including operation time, blood loss, and hospitalization time in patients were recorded. To evaluate patients’ pain and functional recovery, VAS and ODI score were compared before and after surgery, respectively. Radiograph and computed tomography were used to determine pedicle screw loosening, loss of the intervertebral disc space height, and bony fusion rate. Perioperative complications, for instance, postoperative infection, PMMA and cerebrospinal fluid leakage were also recorded.
Evaluation criteria for screw loosening on an X-ray were as follows: (1) Screw displacement greater than 1 mm on a lateral radiograph14,15; and (2) Double-circle sign around the screw on an anterior radiograph16.
The method of measuring the height of the intervertebral disc space was as follows: On a lateral X-ray film, to measure the distance between the posterior edge of dislocated vertebra and the upper vertebral lamina of the lower vertebra, and that between the anterior edge of the lower vertebra and lower lamina of the dislocated vertebra. The average of these two value represented the height of the intervertebral disc space. And the difference between the heights of the intervertebral disc space before surgery and at the last follow-up was considered as the value for loss of the intervertebral disc space height.
Evaluation criteria for spinal fusion were as follows17: (1) Trabecular bone overgrew the graft area; (2) Vertebral body movement was <3 mm or the intervertebral angle change was <5 degree in the flexion-extension radiographs.
All data were measured using the picture archiving and communication systems (PACS) of the PLA Army Characteristic Medical Center. The experimental data were analyzed by using the SPSS 13.0 statistical software package. The measurement data were calculated as mean ± standard deviation (x ± s). VAS and ODI score, and imaging indicators were compared before surgery and final last follow-up using paired-t test. If p was less than 0.05, the difference was considered statistically significant.
Ethics approval and consent to participate
This trial was approved by the ethical committe of Daping Hospital affiliated to Army Medical University, Chongqing, China (IRB number: 2019149).
Results
All 23 patients were followed up for an average time period of 22.5 ± 10.2 months (range, 6–36 months). The average weight, height, and body mass index (BMI) were 48.5 ± 10.8 kg (range, 40.6–67.6 kg), 160.3 ± 6.3 cm (range, 148.2–175 cm), and 19.0 ± 1.5 kg/m2 (range, 18.4–21.4 kg/m2), respectively. The operation time was 145 ± 35 min (range, 85–220 min), the amount of bleeding was 225 ± 87 ml (range, 150–400 ml), and the hospitalization time was 7.9 ± 1.5 d (range, 6–11 d). Autologous blood transfusion was performed if necessary during the operation, and transfusion-related complications were not observed. However, One case of superficial surgical site infection was noted, and the infection was completely under control after an intravenous drip of antibiotics. One case of cerebrospinal fluid (CSF) leakage was observed. The drainage tube was removed after 1 week of bed rest, and then the incision healed completely.
A total of 85 CICPSs and 7 conventional screws were implanted. Each of the CICPSs were injected with approximately 1.0–2.0 ml of PMMA cement. Cement was not observed in the vertebral pedicle or spinal canal. No pulmonary embolism were detected in postoperative CT. Four patients developed cement leakage in the vertebral venous plexus without any neurological symptoms. There were no directly injuries to the nerves, blood vessels, and internal organs during the operation due to screw placement. During PMMA injection procedure, bone cement spillage at the device joint and surgical field contamination also did not occur. According to the criteria, no screw loosening was observed in all CICPSs and conventional screws. Fusion was achieved in all cases (Table 1).
The VAS and ODI scores were changed from 7.06 ± 2.67 points and 24.57 ± 10.63% preoperatively to 1.73 ± 0.81 points and 55.12 ± 28% at the last follow-up. Pain and dysfunction were improved in patients (VAS, p = 0.015, ODI, p = 0.003). The fusion rate of bone graft was 100%, and screw loosening was not observed. The intervertebral disc space height was 7.8 ± 3.7 mm before surgery, 10.1 ± 2.3 mm after surgery and 9.7 ± 1.2 mm at the last follow-up. This value was significantly increased after surgery compared with before surgery(p = 0.036). And the intervertebral disc space height was reduced by 0.4 ± 1.1 mm at the last follow-up compared with after surgery. There was no significant difference between these two periods (p = 0.62). The results are shown in Table 2 and the typical cases are shown in Figs. 2 and 3.
Discussion
Using a pedicle screw system to reconstruct the displaced vertebral body and perform bone fusion is still the main surgical method for patients in lumbar spondylolisthesis with osteoporosis18. Many studies have demonstrated the stability of pedicle screw is significantly reduced in osteoporotic spine with a screw loosening rate up to 12%19,20. Okuyama et al.19 reported that for every 10 mg/cm2 reduction in BMD, the maximum pullout force reduced by 60 N. When BMD was <80 to 90 mg/cm2, a pedicle screwcould not provide sufficient stability when special augmented method were required.
PMMA cement augmentation is considered a reliable and feasible method up to the present time. The traditional method is to inject PMMA into a preset screw tunnel, and then insert a screw. PMMA will disperses uncontrollably leading to a risk of leakage into the spinal canal, intervertebral foramen or vertebral venous plexus21. Moreover, PMMA releases a large amount of heat during the polymerization reaction. Neurologic damage will occur when PMMA closes to the spinal cord or nerve root22. More serious complications also could be observed such as pulmonary embolism23, paraplegia24, or death25.
To prevent this series of complications, hollow CAPS is considered an optional technique that has broad application prospects26,27. Chen et al.28 revealed the following findings: (1) Bone cement mainly flows out from the proximal side hole of CAPS, conversely, there is almost no cement outflow from the distal side hole; (2) In case of the same cement usage, the closer the proximal side hole to screw head, the more significant the increase of the pullout force but the higher the risk of cement leakage into spinal canal. Therefore, authors designed the side holes arranging from small to large on the anterior 2/5th of the screw rod. This design may increase the cement amount outflow from the distal side hole, and then, evenly distributed in the vertebral body. By this method, the cement-leakage risk may be reduced in clinical application.
Revising experience of CAPS is barely reported up to now. It may be very difficult to remove the screws after cement hardened. Once screw loosening or wound infection in the restoration stage, patients will face a disastrous consequences. Therefore, the indications for CAPS using in patients needs further discussion. Based on the published literature, patients with vertebral osteoporosis is a necessary prerequisite for using CAPS in various studies, which is considered as a general consensus. The most commonly followed surgical indications include vertebral fractures, neurological deficit seriously decreasing quality of life, kyphosis with persistent symptoms and progressive kyphosis. In addition, Sawakami et al.21, Park et al.29 and Cho et al.30 had achieved satisfactorily clinical efficacy in the treatment of patients with pseudoarthrosis following Kummell’s lesion and vertebral fractures. So they considered secondary pseudarthrosis is one of the indications for CAPS augmentation. However, authors suggest the indications for using CICPS should include the following aspects: (1) Persistence low-back pain with aggravation; (2) Severe osteoporosis and conventional screw showed an inadequate holding force during the operation; (3) Progressive spondylolisthesis; (4) Symptoms and signs of cauda equina or nerve root; and (5) Patients with high weight.
Authors reviewed all the published literature pertaining to the use of CAPS in osteoporotic spine cases. Only three researches performed a controlled study relating to CAPS and noncement screws. El Saman et al.31 noted the loosening rate of CAPSs is 4.3%, whereas in noncement screws group, the loosening rate was 62.8%. Thus, a significantly lower loosening rate was showed in CAPSs compared to noncement ones. Sawakami et al.21 reported the screw loosening rate of CAPS was significantly lower than that of the control group (29.4% vs. 71.4%), meanwhile, a statistically significant increase was showed in fusion rate of CAPS group (94.1% vs. 76.1%). Patients’ back pain relieved obviously at follow-up (64.7%), and no PMMA-cement related complications was observed. Seo et al.32 reported two patients suffered from neurologic deficit due to PMMA leakage, but VAS and ODI was achieved a significant improvement in both cement and noncement groups. However, five cases of screw loosening occurred in the noncement group that further required a revision surgery for augmentation technology. Although, the first two studies used CAPS in patients with Kummell’s lesion and the last 1 in pseudoathrosis. We may conclude CAPS was possible to achieve satisfactory results in patients with osteoporosis.
Four clinical studies used CAPS in lumbar spondylolisthesis with osteoporosis were found. Pinera et al.8 investigated the clinical and radiological outcome of 23 patients with degenerative lumbar instability and osteoporosis treated with fusion using a type of CAPS. Pain and function improved at 6 months and this status was maintained at the final follow-up. The PMMA leakage rate was 29.3%. Three deep infections and one superfificial infection occured (17.4%). No clinical or radiological cases of non-fusion were observed. Jang et al.33 reported a comparative clinical studies. They evaluated 34 patients (17 patients with CAPS and 17 patients without cement augmentation) undergoing pedicle screw fixation for lumbar spondylolisthesis with osteoporosis. The results showed there was no difference in low back pain relief (VAS) between the two types of screw. No major perioperative complication in both groups. One patient (CAPS group, 5.9%) underwent revision surgery for the removal of a drainage tube, and one patient (noncement group, 5.9%) underwent revision surgery because of subcutaneous fluid collection. There was no events of radiological loosening, or pulling out of screws. Chandra et al. evaluated 25 patients separately underwent open-TLIF34 and minimally invasive-TLIF35 using CAPS fixation for lumbar spondylolisthesis. In the two studies, there was a statistically significant improvement in the VAS and ODI scores postoperatively. No events of radiological loosening, or pulling out of screws were observed. None of the patients had postoperative wound infection. Only one event of PMMA leakage was occured intraoperatively in open-TLIF operation (4%).
Authers used CICPSs in 23 patients with lumbar spondylolisthesis and osteoporosis. 4 patients (17.4%) were observed PMMA leakage, determined by X-ray film, without any neurological symptoms. In most studies, PMMA leakage presented no symptoms or only mild symptoms such as transient sensorimotor deficit. Janssen et al.36 reported that the incidence of asymptomatic PMMA leakage was 66.7% and that of symptoms was 5.5%. In symptomatic cases, 1.2% of the patients needed revision surgery to remove the screws and cement. Martín-Fernández et al.37 observed a 62.3% incidence of spinal leakage in 313 patients. 1.55% of the cases had symptoms which were presented as radicular pain of lower limbs. Lubansu et al.38 summarized some suggested tips to prevent bone cement leakage. However, up to now, the leakage rate of bone cement showed big difference26,34,35, which reason might be related to the small sample size or different screw design in different studies.
Pedicle screws with cement augmentation provided a strong holding force for the restruction of slipped vertebrae and maintain its stability to achieve interbody fusion. In the study, the height of intervertebral space maintained well during the follow up and all cases achieved bony fusion. Fixation loosening or backout was not observed in all CICPSs and no cases required revision. Similarly, the fusion rates were 100% in CAPS group compared with the noncement group in study by Sawakami et al.21. However, in control group, 3 (14.3%) cases occoured pedicle screw pullout and one of them required reoperation to stabilize the spine. Another 5 noncement cases needed to perform revision surgery reported by Seo et al.32. Martín-Fernández et al.37 reported the highest revision rate (17.9%) of the patients using CAPS. However, the revision reason for these 56 cases was not fixation loosening, but the adjacent segment-related issues such as pseudo-arthrosis formation and adjacent vertebral fracture.
Singh V et al.39 did a systematic analysis for cement-augmented screw. The results showed that the most commonly methods to evaluate faunctional recovery and physical pain were ODI and VAS scale. The average VAS score before surgery was 8.4 (range 8–9.2) compared to 2.3 (range 1.42–4.8) at the last follow up. The average improvement ODI for assessment of faunctional recovery was 42.1. Good to excellent clinical effect was reported in all these patients using CAPS. Vas and ODI are also used as evaluation indexes in our study. Last follow-up VAS was 1.73 compared with 7.06 preoperatively and ODI improved from 24.57 to 55.12. CICPS also showed a great improvement in pain relief and function recovery similar to these series.
Elderly patients, especially over 69 years old, were noticed a high incidence of complications with internal fixation treatment40. Singh V et al.39 reported 16 (1.5%) patients was observed superficial infection which treated with antibiotics; and 21 (2.1%) cases noted deep infection after surgery which were performed a debridement. The number of cement pulmonary embolism was 16 cases (1.5%). Cauda equina syndrome and cerebrospinal fluid leakage was noted in 1 patient and 3 ones, respectively. In our study, one case (8.6%) of superficial infection and one case (8.6%) of dural leak occurred. No overall cement pulmonary embolism and deep surgical site infection were observed. However, up to the present no enough evidence to prove CICPS reducing the risk of complications in elderly patients.
This study has several limitations. Firstly, the sample size is small and the follow-up time is short, thus a study with more patients and longer follow-up duration is needed to further confirm our results. Secondly, since the effectiveness of CICPS had been biomechanically evaluated before13, here only clinical evaluation was performed. A controlled randomized study could be suggested for further study. Finally, standard application protocol of CAPS should be developed to avoid the catastrophic consequences of excessive application, which will be our future research focus.
In summary, CICPS is a clinically safe and effective means which is used to augment pedicle screws in lumbar spondylolisthesis with osteoporosis. Up to present no enough evidence to recommend CAPS for osteoporotic spine. However, CICPS using PMMA augmentation may be considered a feasible surgical technique. This study could provide evidence-based basis for developing the guidelines of the CAPS application, especially in lumbar spondylolisthesis with osteoporosis.
Data availability
The datasets generated and analyzed during the present study are available from the corresponding author on reasonable request.
References
Patel, V. et al. MicroCT evaluation of normal and osteoarthritic bone structure in human knee specimens. J. Orthop. Res. 21, 6–13 (2003).
Schwartz, Z. et al. Effect of micrometer-scale roughness of the surface of Ti6Al4V pedicle screws in vitro and in vivo. J. Bone Jt. Surg. Am. 90, 2485–2498 (2008).
Mummaneni, P. V., Haddock, S. M., Liebschner, M. A., Keaveny, T. M. & Rosenberg, W. S. Biomechanical evaluation of a double-threaded pedicle screw in elderly vertebrae. J. Spinal Disord. Tech. 15, 64–68 (2002).
Inceoglu, S., Ferrara, L. & McLain, R. F. Pedicle screw fixation strength: pullout versus insertional torque. Spine J. 4, 513–518 (2004).
Yi, X., Wang, Y., Lu, H., Li, C. & Zhu, T. Augmentation of pedicle screw fixation strength using an injectable calcium sulfate cement: an in vivo study. Spine . 33, 2503–2509 (2008).
Bostan, B. et al. A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions. Acta Orthop. Traumatol. Turc. 43, 272–276 (2009).
Liu, D. et al. Augmentation of pedicle screw stability with calcium sulfate cement in osteoporotic sheep: biomechanical and screw-bone interfacial evaluation. J. Spinal Disord. Tech. 24, 235–241 (2011).
Pinera, A. R. et al. Instrumented lumbar arthrodesis in elderly patients: Prospective study using cannulated cemented pedicle screw instrumentation. Eur. Spine J. 20(3 suppl), 408–414 (2011).
Kanis, J. A., Melton, L. J., Christiansen, C., Johnston, C. C. & Khaltaev, N. The diagnosis of osteoporosis. J. Bone Min. Res. 9, 1137–1141 (1994).
Soshi, S., Shiba, R., Kondo, H. & Murota, K. An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine. 16, 1335–1341 (1991).
Meyerding, H. W. Spondylolisthesis: surgical treatment and results. Surg. Gynecol. Obstet. 54, 371–377 (1932).
Liu, Y. et al. Biomechanical and finite element analyses of bone cement-Injectable cannulated pedicle screw fixation in osteoporotic bone. J. Biomed. Mater. Res. B Appl. Biomater. 104, 960–967 (2016).
Dai, F. et al. Surgical treatment of the osteoporotic spine with bone cement-injectable cannulated pedicle screw fixation: technical description and preliminary application in 43 patients. Clin. 70, 114–119 (2015).
Wu, J. C. et al. Pedicle screw loosening in dynamic stabilization: incidence, risk, and outcome in 126 patients. Neurosurg. Focus. 31, E9 (2011).
Ko, C. C. et al. Screw loosening in the Dynesys stabilization system: radiographic evidence and effect on outcomes. Neurosurg. Focus. 28, E10 (2010).
Dakhil-Jerew, F., Jadeja, H., Cohen, A. & Shepperd, J. A. Inter-observer reliability of detecting Dynesys pedicle screw using plain X-rays: a study on 50 post-operative patients. Eur. Spine J. 18, 1486–1493 (2009).
Lowe, T. G., Tahernia, A. D., O’Brien, M. F. & Smith, D. A. Unilateral transforaminal posterior lumbar interbody fusion (TLIF): indications, technique, and 2-year results. J. Spinal Disord. Tech. 15, 31–38 (2002).
Harrington, J. F. Jr. & Park, M. C. Single level arthrodesis as treatment for midcervical fracture subluxation: a cohort study. J. Spinal Disord. Tech. 20, 42–48 (2007).
Okuyama, K. et al. Influence of bone mineral density on pedicle screw fixation: a study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients. Spine J. 1, 402–407 (2001).
Lonstein, J. E. et al. Complications associated with pedicle screws. J. Bone Jt. Surg. Am. 81, 1519–1528 (1999).
Sawakami, K. et al. Polymethylmethacrylate augmentation of pedicle screws increases the initial fixation in osteoporotic spine patients. J. Spinal Disord. Tech. 25, E28–E35 (2012).
Wilkes, R. A., Mackinnon, J. G. & Thomas, W. G. Neurological deterioration after cement injection into a vertebral body. J. Bone Jt. Surg. Br. 76, 155 (1994).
Jang, J. S., Lee, S. H. & Jung, S. K. Pulmonary embolism of polymethylmethacrylate after percutaneous vertebroplasty: a report of three cases. Spine . 27, E416–418 (2002).
Lee, B. J., Lee, S. R. & Yoo, T. Y. Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: a case report. Spine . 27, E419–422 (2002).
Childers, J. C., Jr. Cardiovascular collapse and death during vertebroplasty. Radiology. 228, 902; author reply 902–903 (2003).
Frankel, B. M., Jones, T., Wang, C. Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery. 61, 531–537; discussion 537–538 (2007).
Fransen, P. Increasing pedicle screw anchoring in the osteoporotic spine by cement injection through the implant. Technical note and report of three cases. J. Neurosurg. Spine. 7, 366–369 (2007).
Chen, L. H. et al. Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: influences of radial hole and pilot hole tapping. Clin. Biomech. 24, 613–618 (2009).
Park, S. J., Kim, H. S., Lee, S. K. & Kim, S. K. Bone cement-augmented percutaneous short segment fixation: an effective treatment for Kummell’s disease? J. Korean Neurosurg. Soc. 58, 54–59 (2015).
Cho, Y. Posterior vertebrectomy and circumferential fusion for the treatment of advanced thoracolumbar Kummell disease with neurologic deficit. Asian Spine J. 11, 634–640 (2017).
El Saman, A. et al. Reduced loosening rate and loss of correction following posterior stabilization with or without PMMA augmentation of pedicle screws in vertebral fractures in the elderly. Eur. J. Trauma. Emerg. Surg. 39, 455–460 (2013).
Seo, J. H., Ju, C. I., Kim, S. W., Kim, J. K. & Shin, H. Clinical efficacy of bone cement augmented screw fixation for the severe osteoporotic spine. Korean J. Spine. 9, 79–84 (2012).
Jang, S. H., Lee, J. H., Cho, J. Y., Lee, H. Y. & Lee, S. H. The efficacy of hydroxyapatite for screw augmentation in osteoporotic patients. Neurol. Med. Chir. 53, 875–881 (2013).
Chandra, V. V. et al. Segmental polymethylmethacrylate-augmented fenestrated pedicle screw fixation for lumbarspondylolisthesis in patients with osteoporosis- A case series and review of literature. Neurol. India. 65, 89–95 (2017).
Chandra Vemula, V. R., Prasad, B. C., Jagadeesh, M. A., Vuttarkar, J. & Akula, S. K. Minimally invasive transforaminal lumbar interbody fusion using bone cement-augmented pedicle screws for lumbar spondylolisthesis in patients with osteoporosis. Case series and review of literature. Neurol. India. 66, 118–125 (2018).
Janssen, I. et al. Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine. Spine J. 2, 837–844 (2017).
Martín-Fernández, M. et al. Potential risks of using cement-augmented screws for spinal fusion in patients with low bone quality. Spine J. 17, 1192–1199 (2017).
Lubansu, A., Rynkowski, M., Abeloos, L., Appelboom, G. & Dewitte, O. Minimally invasive spinal arthrodesis in osteoporotic population using a cannulated and fenestrated augmented screw: Technical description and clinical experience. Minim. Invasive Surg. 2012, 507826 (2012).
Singh, V., Mahajan, R., Das, K., Chhabra, H. S. & Rustagi, T. Surgical trend analysis for use of cement augmented pedicle screws in osteoporosis of spine: a systematic review (2000–2017). Glob. Spine J. 9, 783–795 (2019).
Daubs, M. D., Lenke, L. G., Cheh, G., Stobbs, G. & Bridwell, K. H. Adult spinal deformity surgery. complications and outcomes in patients over age 60. Spine. 32, 2238–2244 (2007).
Acknowledgements
This work was supported by grants from the National Natural Science Foundation of China (No. 81902257).
Author information
Authors and Affiliations
Contributions
Yao-yao Liu and Fei Dai designed/performed most of the investigation, data analysis and wrote the manuscript; Fei Dai, Peng Liu and Jian-hua Zhao performed the operations; Jun Xiao provided imaging assistance; Jun Xiao, Xiang Yin and Ming-yong Liu contributed to interpretation of the data and analyses. All of the authors have read and approved the manuscript.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Liu, Yy., Xiao, J., Yin, X. et al. Clinical efficacy of Bone Cement-injectable Cannulated Pedicle Screw Short Segment Fixation for Lumbar Spondylolisthesis with Osteoporosise. Sci Rep 10, 3929 (2020). https://doi.org/10.1038/s41598-020-60980-w
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-020-60980-w
- Springer Nature Limited
This article is cited by
-
Anatomic distribution of basivertebral foramen with a magistral form in vertebral bodies of T10~L5 and its clinical significance for extensive epidural cement leakage in cement-augmented pedicle screw fixation: a multicenter case–control study
Journal of Orthopaedic Surgery and Research (2024)
-
Second-generation bone cement-injectable cannulated pedicle screws for osteoporosis: biomechanical and finite element analyses
Journal of Orthopaedic Surgery and Research (2023)
-
Is 3D-printed prosthesis stable and economic enough for anterior spinal column reconstruction after spinal tumor resection? A retrospective comparative study between 3D-printed off-the-shelf prosthesis and titanium mesh cage
European Spine Journal (2023)
-
Comparison of predictive performance for cage subsidence between CT-based Hounsfield units and MRI-based vertebral bone quality score following oblique lumbar interbody fusion
European Radiology (2023)
-
Clinical evaluation of the efficacy of a new bone cement-injectable cannulated pedicle screw in the treatment of spondylolysis-type lumbar spondylolisthesis with osteoporosis: a retrospective study
BMC Musculoskeletal Disorders (2022)