Contact Stress and Wear Analysis of Zirconia Against Alumina for Normal and Physically Demanding Loads in Hip Prosthesis

  • Published:
Journal of Bionic Engineering Aims and scope Submit manuscript

Abstract

Risky gait activities lead to severe wear in orthopaedic implants during postoperative periods. The aim of the present study is to predict the linear and volumetric wear of zirconia (ZrO2) vs alumina (Al2O3) hip implants subject to risky and normal gait activities. Initially, the gait loads pertaining to risky gait activities were converted to equivalent normal loads. Then using the computed normal loads, friction and wear coefficients of ZrO2 ball against Al2O3 disc were calculated from Pin-on-Disc (POD) tribometer under dry and lubricating conditions. Saline solution, a bio-lubricant was utilized for lubrication purpose to mimic synovial fluid properties. Nineteen gait activities stair ascending or descending, carrying load, lifting load and ladder up or down etc., grouped as A, B, C and D were used to determine friction and wear coefficients. Finite Element Method (FEM) was employed to predict the wear of the bearing couple. The developed contact pressure for these gait activities was then utilized to compute linear and volumetric wear for 2 million cycles. Our findings suggests that, patients regularly involved in group C and D type gait activities were likely to cause more wear which may accelerate early implant failure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Stolk J, Verdonschot N, Huiskes R. Stair climbing is more detrimental to the cement in hip replacement than walking. Clinical Orthopaedics and Related Research®, 2002, 405, 294–305.

    Article  Google Scholar 

  2. Varady P A, Glitsch U, Augat P. Loads in the hip joint during physically demanding occupational tasks: A motion analysis study. Journal of Biomechanics, 2015, 48, 3227–3233.

    Article  Google Scholar 

  3. Mall N A, Nunley R M, Zhu J J, Maloney W J, Barrack R L, Clohisy J C. The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene. Clinical Orthopaedics and Related Research®, 2011, 469, 372–381.

    Article  Google Scholar 

  4. Wagner M. Medium-term results of a modern metal-on-metal system in total hip replacement. Arthroplasty, Springer-Verlag, Tokyo, Japan, 2001, 49–62.

    Google Scholar 

  5. Lhotka C, Szekeres T, Steffan I, Zhuber K, Zweymüller K. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. Journal of Orthopaedic Research, 2003, 21, 189–195.

    Article  Google Scholar 

  6. Yoo J J, Kim Y M, Yoon K S, Koo K H, Kim J W, Nam K W, Kim H J. Contemporary alumina-on-alumina total hip arthroplasty performed in patients younger than forty years: A 5-year minimum follow-up study. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2006, 78, 70–75.

    Article  Google Scholar 

  7. Affatato S, Ruggiero A, Merola M. Advanced biomaterials in hip joint arthroplasty. A review on polymer and ceramics composites as alternative bearings. Composites Part B: Engineering, 2015, 83, 276–283.

    Article  Google Scholar 

  8. Stewart T D, Tipper J L, Insley G, Streicher R M, Ingham E, Fisher J. Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation. The Journal of Arthroplasty, 2003, 18, 726–734.

    Article  Google Scholar 

  9. Borruto A. A new material for hip prosthesis without considerable debris release. Medical Engineering & Physics, 2010, 32, 908–913.

    Article  Google Scholar 

  10. Mojumder S, Sikdar S, Ghosh S K. Experimental study of wear for implant materials under dry sliding conditions. Industrial Lubrication and Tribology, 2017, 69, 828–832.

    Article  Google Scholar 

  11. Saklakoğlu N, Saklakoğlu İ E, Short K T, Collins G A. Tribological behavior of PIII treated AISI 316 L austenitic stainless steel against UHMWPE counterface. Wear, 2006, 261, 264–268.

    Article  Google Scholar 

  12. Aherwar A, Patnaik A, Bahraminasab M, Singh A. Preliminary evaluations on development of new materials for hip joint femoral head. Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications, 2019, 233, 885–899.

    Article  Google Scholar 

  13. Aherwar A, Singh A, Patnaik A. A study on mechanical behavior and wear performance of a metal-metal Co-30Cr biomedical alloy with different molybdenum addition and optimized using Taguchi experimental design. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2018, 40, 213.

    Article  Google Scholar 

  14. Borjali A, Monson K, Raeymaekers B. Friction between a polyethylene pin and a microtextured CoCrMo disc, and its correlation to polyethylene wear, as a function of sliding velocity and contact pressure, in the context of metal-on-polyethylene prosthetic hip implants. Tribology international, 2018, 127, 568–574.

    Article  Google Scholar 

  15. Henak C R, Kapron A L, Anderson A E, Ellis B J, Maas S A, Weiss J A. Specimen-specific predictions of contact stress under physiological loading in the human hip: validation and sensitivity studies. Biomechanics and Modeling in Mechanobiology, 2014, 13, 387–400.

    Article  Google Scholar 

  16. Shankar S, Nithyaprakash R. Wear prediction on silicon nitride bearing couple in human hip prosthesis using finite element concepts. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 2014, 228, 717–724.

    Article  Google Scholar 

  17. Nithyaprakash R, Shankar S, Uddin M S. Computational wear assessment of hard on hard hip implants subject to physically demanding tasks. Medical & Biological Engineering & Computing, 2018, 899–910.

  18. Shankar S, Nithyaprakash R. Predicting the wear of soft-on-hard bearing couples for human hip prosthesis using finite element concepts. Journal of Mechanics in Medicine and Biology, 2016, 16, 1650020.

    Article  Google Scholar 

  19. Liu F, Fisher J. Effect of an edge at cup rim on contact stress during micro-separation in ceramic-on-ceramic hip joints. Tribology International, 2017, 113, 323–329.

    Article  Google Scholar 

  20. Alkhatib S E, Mehboob H, Tarlochan F. Finite element analysis of porous titanium alloy hip stem to evaluate the biomechanical performance during walking and stair climbing. Journal of Bionic Engineering, 2019, 16, 1103–1115.

    Article  Google Scholar 

  21. Sun C N, Wang L, Kang J F, Li D C, Jin Z M. Biomechanical optimization of elastic modulus distribution in porous femoral stem for artificial hip joints. Journal of Bionic Engineering, 2018, 15, 693–702.

    Article  Google Scholar 

  22. Curreli C, Di Puccio F, Mattei L. Application of the finite element submodeling technique in a single point contact and wear problem. International Journal for Numerical Methods in Engineering, 2018, 116, 708–722.

    Article  MathSciNet  Google Scholar 

  23. Elkins J M, O’Brien M K, Stroud N J, Pedersen D R, Callaghan J J, Brown T D. Hard-on-hard total hip impingement causes extreme contact stress concentrations. Clinical Orthopaedics and Related Research®, 2011, 469, 454–463.

    Article  Google Scholar 

  24. Shankar S, Nithyaprakash R, Santhosh B R, Uddin M S, Pramanik A. Finite element submodeling technique to analyze the contact pressure and wear of hard bearing couples in hip prosthesis. Computer Methods in Biomechanics and Biomedical Engineering, 2020, 23, 422–431.

    Article  Google Scholar 

  25. Guezmil M, Bensalah W, Mezlini S. Tribological behavior of UHMWPE against TiAl6V4 and CoCr28Mo alloys under dry and lubricated conditions. Journal of the Mechanical Behavior of Biomedical Materials, 2016, 63, 375–385.

    Article  Google Scholar 

  26. Xiong F, Manory R R. The effect of test parameters on alumina wear under low contact stress. Wear, 1999, 236, 240–245.

    Article  Google Scholar 

  27. Davim J P, Marques N. Evaluation of tribological behaviour of polymeric materials for hip prostheses application. Tribology Letters, 2001, 11, 91–94.

    Article  Google Scholar 

  28. Guezmil M, Bensalah W, Mezlini S. Tribological behavior of CoCr28Mo/CoCr28Mo pair in the presence of bio-lubrication. Journal of Bionic Engineering, 2018, 15, 703–712.

    Article  Google Scholar 

  29. Luo Y, Yang L, Tian M C. Influence of bio-lubricants on the tribological properties of Ti6Al4V alloy. Journal of Bionic Engineering, 2013, 10, 84–89.

    Article  Google Scholar 

  30. Shankar S, Nithyaprakash R, Sugunesh A P, Selvamani K A, Uddin M S. Experimental and finite element wear study of silicon nitride against alumina for hip implants with bio-lubricant for various gait activities. Silicon, 2020, https://doi.org/10.1007/s12633-020-00462-w.

  31. Marshek K, Chen H. Discretization pressure-wear theory for bodies in sliding contact. Journal of Tribology, 1989, 111, 95–100.

    Article  Google Scholar 

  32. Archard J F. Contact and rubbing of flat surfaces. Journal of Applied Physics, 1953, 24, 981–988.

    Article  Google Scholar 

  33. Queiroz R D, Oliveira A L L, Trigo F C, Lopes J A. A finite element method approach to compare the wear of acetabular cups in polyethylene according to their lateral tilt in relation to the coronal plane. Wear, 2013, 298, 8–13.

    Article  Google Scholar 

  34. Fialho J C, Fernandes P R, Eça L, Folgado J. Computational hip joint simulator for wear and heat generation. Journal of Biomechanics, 2007, 40, 2358–2366.

    Article  Google Scholar 

  35. Uddin M S, Zhang L C. Predicting the wear of hard-on-hard hip joint prostheses. Wear, 2013, 301, 192–200.

    Article  Google Scholar 

  36. Essner A, Sutton K, Wang A. Hip simulator wear comparison of metal-on-metal, ceramic-on-ceramic and crosslinked UHMWPE bearings. Wear, 2005, 259, 992–995.

    Article  Google Scholar 

  37. Suh M S, Chae Y H, Kim S S. Friction and wear behavior of structural ceramics sliding against zirconia. Wear, 2008, 264, 800–806.

    Article  Google Scholar 

  38. Shankar S, Nithyaprakash R. Effect of radial clearance on wear and contact pressure of hard-on-hard hip prostheses using finite element concepts. Tribology Transactions, 2014, 57, 814–820.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Subramaniam Shankar.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Shankar, S., Nithyaprakash, R., Sugunesh, P. et al. Contact Stress and Wear Analysis of Zirconia Against Alumina for Normal and Physically Demanding Loads in Hip Prosthesis. J Bionic Eng 17, 1045–1058 (2020). https://doi.org/10.1007/s42235-020-0078-4

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s42235-020-0078-4

Keywords

Navigation