Abstract
The present study aims to study the indoor and outdoor air quality in an urban center and its immediate rural areas. The measurements of particulate matter (PM10 and PM2.5) and the Air Quality Index (AQI) during cooking hours in the morning, daytime, and evening, using a real-time portable air sampler were performed as a part of the study. Five residential colonies in urban and rural localities of a North Indian city Lucknow, covering a total of sixty households (HHs), were selected for detailed sampling over a period of two months (February and March 2018). A major difference in the cooking pattern was observed in urban and rural localities in terms of the use of cooking fuels. The average indoor PM2.5 concentrations in urban and rural HHs were 115.4 µg/m3 and 337.2 µg/m3, respectively. These values were 1.3 and 7.8 times higher than the outdoor PM2.5 concentration levels. Similarly, the average indoor PM10 concentrations in urban and rural HHs were 178.3 µg/m3 and 362.4 µg/m3, respectively. These values were 1.2 and 4.8 times higher than the outdoor levels. The average AQI be the highest (368.8) for rural indoors, primarily due to biomass burning, and the lowest (84.9) for rural outdoors during the sampling period. A majority (> 70%) of the rural HHs, with women being the most susceptible groups for the exposure, reported ailments like prolonged coughing and eye irritation during cooking hours, while urban HHs were relatively better off. The difference in the indoor and outdoor urban and rural air quality was observed to be the least during the daytime and evening, indicating the variations in emission patterns during the cooking hours. It is expected that the outcome of this study will help in taking progressive measures to reduce the emission of particulate matter while cooking, especially in vulnerable rural households.
Similar content being viewed by others
Data availability
The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.
References
Agarwal A, Jain A, Kogta S (2017) Air pollution and quality monitoring using IoT. https://repository.iiitd.edu.in/xmlui/handle/123456789/557
Andresen PR, Ramachandran G, Pai P, Maynard A (2005) Women’s personal and indoor exposures to PM2. 5 in Mysore, India: impact of domestic fuel usage. Atmos Environ 39(30):5500–5508. https://doi.org/10.1016/j.atmosenv.2005.06.004
Arif M, Kumar R, Kumar R, Zusman E, Singh RP, Gupta A (2018) Assessment of indoor and outdoor black carbon emissions in rural areas of Indo-Gangetic Plain: seasonal characteristics, source apportionment and radiative forcing. Atmos Environ 191:227–240. https://doi.org/10.1016/j.atmosenv.2018.07.057
Arora P, Jain S, Sachdeva K (2014) Laboratory based assessment of cookstove performance using energy and emission parameters for North Indian cooking cycle. Biomass Bioenerg 69:211–221. https://doi.org/10.1016/j.biombioe.2014.07.012
Balakrishnan K, Sankar S, Parikh J, Padmavathi R, Srividya K, Venugopal V, Pandey VL (2002) Daily average exposures to respirable particulate matter from combustion of biomass fuels in rural households of southern India. Environ Health Perspect 110(11):1069–1075. https://doi.org/10.1289/ehp.021101069
Basu AK, Byambasuren T, Chau NH, Khanna N (2020) Cooking fuel choice, indoor air quality and child mortality in India. Indoor Air Quality and Child Mortality in India. IZA Discussion Paper No. 13295, SSRN: https://ssrn.com/abstract=3614243
Bentayeb M, Norback D, Bednarek M, Bernard A, Cai G, Cerrai S, Annesi-Maesano I (2015) Indoor air quality, ventilation and respiratory health in elderly residents living in nursing homes in Europe. Eur Respir J 45(5):1228–1238. https://doi.org/10.1183/09031936.00082414
Butt EW, Rap A, Schmidt A, Scott CE, Pringle KJ, Reddington CL, Spracklen DV (2016) The impact of residential combustion emissions on atmospheric aerosol, human health, and climate. Atmos Chem Phys 16(2):873–905. https://doi.org/10.5194/acp-16-873-2016
Chen C, Zhao B (2011) Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factor. Atmos Environ 45(2):275–288. https://doi.org/10.1016/j.atmosenv.2010.09.048
Cohen AJ, Brauer M, Burnett R, Anderson HR, Frostad J, Estep K, Forouzanfar MH (2017) Estimates and 25-year trends of the global burden of disease attributable to ambient air pollution: an analysis of data from the Global Burden of Diseases Study 2015. Lancet 389(10082):1907–1918. https://doi.org/10.1016/S0140-6736(17)30505-6
Colbeck I, Nasir ZA, Ali Z (2010) Characteristics of indoor/outdoor particulate pollution in urban and rural residential environment of Pakistan. Indoor Air 20(1):40–51. https://doi.org/10.1111/j.1600-0668.2009.00624.x
Cusworth DH, Mickley LJ, Sulprizio MP, Liu T, Marlier ME, DeFries RS, Gupta P (2018) Quantifying the influence of agricultural fires in northwest India on urban air pollution in Delhi, India. Environ Res Lett 13(4):044018. https://doi.org/10.1088/1748-9326/aab303
de la Sota C, Lumbreras J, Pérez N, Ealo M, Kane M, Youm I, Viana M (2018) Indoor air pollution from biomass cookstoves in rural Senegal. Energy Sustain Dev 43:224–234. https://doi.org/10.1016/j.esd.2018.02.002
Fan G, Xie J, Yoshino H, Yanagi U, Hasegawa K, Kagi N, Liu J (2018) Indoor environmental conditions in urban and rural homes with older people during the heating season: a case in a cold region, China. Energy Build 167:334–346. https://doi.org/10.1016/j.enbuild.2018.01.064
Gopalakrishnan P, Saravanakumar P, Joshi NN, Harish B, Jeyanthi J (2021) Review on indoor air quality in Indian buildings. In: IOP Conference Series: Materials Science and Engineering (Vol. 1145, No. 1, p. 012037). IOP Publishing. https://doi.org/10.1088/1757-899X/1145/1/012037
Houselisting and Housing Census Data Highlights—2011. https://censusindia.gov.in/2011-common/censusdata2011.html. Last Accessed 16 Oct 2018
India P (2011) Census of India 2011 provisional population totals. New Delhi: Office of the Registrar General and Census Commissioner
IndiaSpend (2017) Designing a new #Breathe human interface for real-time air quality monitoring data. https://www.indiaspend.com/the-air-we-breathe/design-anew-breathe-human-interface-for-real-time-air-qualitymonitoring-data-76441. Accessed 10 Aug 2020
Kamal R, Srivastava AK, Kesavachandran CN, Bihari V, Singh A (2021) Chronic obstructive pulmonary disease (COPD) in women due to indoor biomass burning: a meta analysis. Int J Environ Health Res. https://doi.org/10.1080/09603123.2021.1887460
Kankaria A, Nongkynrih B, Gupta SK (2014) Indoor air pollution in India: implications on health and its control. Indian J Commun Med off Publ Indian Assoc Prev Soc Med 39(4):203. https://doi.org/10.4103/0970-0218.143019
Klein F, Farren NJ, Bozzetti C, Daellenbach KR, Kilic D, Kumar NK, El Haddad I (2016a) Indoor terpene emissions from cooking with herbs and pepper and their secondary organic aerosol production potential. Sci Rep 6(1):1–7. https://doi.org/10.1038/srep366232016a
Klein F, Platt SM, Farren NJ, Detournay A, Bruns EA, Bozzetti C, El Haddad I (2016b) Characterization of gas-phase organics using proton transfer reaction time-of-flight mass spectrometry: cooking emissions. Environ Sci Technol 50(3):1243–1250. https://doi.org/10.1021/acs.est.5b04618,%202016b
Landrigan PJ, Fuller R, Acosta NJR, Adeyi O, Arnold R, Basu N, Zhong M (2018) The lancet commission on pollution and health. Lancet 391(10119):462–512. https://doi.org/10.1016/s0140-6736(17)32345-0
Lawrence A, Fatima N (2014) Urban air pollution and its assessment in Lucknow City—the second largest city of North India. Sci Total Environ 488:447–455. https://doi.org/10.1016/j.scitotenv.2013.10.106
Li C, Kang S, Chen P, Zhang Q, Guo J, Mi J, Smith KR (2012) Personal PM2. 5 and indoor CO in nomadic tents using open and chimney biomass stoves on the Tibetan Plateau. Atmos Environ 59:207–213. https://doi.org/10.1016/j.atmosenv.2012.05.033
Liu T, Wang Z, Wang X, Chan CK (2018) Primary and secondary organic aerosol from heated cooking oil emissions. Atmos Chem Phys 18(15):11363–11374. https://doi.org/10.5194/acp-18-11363-2018,%202018
Masera OR, Saatkamp BD, Kammen DM (2000) From linear fuel switching to multiple cooking strategies: a critique and alternative to the energy ladder model. World Dev 28(12):2083–2103. https://doi.org/10.1016/S0305-750X(00)00076-0
Masiwal R, Sawlani R, Singh R, Chakraborty M, Shukla DK, Ranjan A, Sharma C (2021). Indoor Air Pollution in Indian Rural Kitchen. https://doi.org/10.1007/s12647-021-00472-y
Massey D, Masih J, Kulshrestha A, Habil M, Taneja A (2009) Indoor/outdoor relationship of fine particles less than 2.5 μm (PM2. 5) in residential homes locations in central Indian region. Build Environ 44(10):2037–2045. https://doi.org/10.1016/j.buildenv.2009.02.010
Massey D, Kulshrestha A, Masih J, Taneja ABEJ (2012) Seasonal trends of PM10, PM5. 0, PM2. 5 & PM1. 0 in indoor and outdoor environments of residential homes located in North-Central India. Build Environ 47:223–231. https://doi.org/10.1016/j.buildenv.2011.07.018
Mondal NK, Konar S, Banerjee A, Datta JK (2011) A comparative assessment of status of indoor air pollution of few selected families of rural and urban area of Burdwan town and its adjoining area. Int J Environ Sci 1(5):736–743
Nair VS, Moorthy KK, Alappattu DP, Kunhikrishnan PK, George S, Nair PR, Reddy RR (2007) Wintertime aerosol characteristics over the Indo-Gangetic Plain (IGP): impacts of local boundary layer processes and long-range transport. J Geophys Res Atmos. https://doi.org/10.1029/2006JD008099
Pandey VL, Chaubal A (2011) Comprehending household cooking energy choice in rural India. Biomass Bioenerg 35(11):4724–4731. https://doi.org/10.1016/j.biombioe.2011.09.020
Pandey A, Venkataraman C (2014) Estimating emissions from the Indian transport sector with on-road fleet composition and traffic volume. Atmos Environ 98:123–133. https://doi.org/10.1016/j.atmosenv.2014.08.039
Pandey A, Sadavarte P, Rao AB, Venkataraman C (2014) Trends in multi-pollutant emissions from a technology-linked inventory for India: II. Residential, agricultural and informal industry sectors. Atmos Environ 99:341–352. https://doi.org/10.1016/j.atmosenv.2014.09.080
Pandey A, Brauer M, Cropper ML, Balakrishnan K, Mathur P, Dey S, Dandona L (2021) Health and economic impact of air pollution in the states of India: the Global Burden of Disease Study 2019. Lancet Planetary Health 5(1):e25–e38. https://doi.org/10.1016/S2542-5196(20)30298-9
Pohekar SD, Kumar D, Ramachandran M (2005) Dissemination of cooking energy alternatives in India—a review. Renew Sustain Energy Rev 9(4):379–393. https://doi.org/10.1016/j.rser.2004.05.001
Ramachandra TV (2009) Emissions from India’s transport sector: state wise synthesis. Atmos Environ 43(34):5510–5517. https://doi.org/10.1016/j.atmosenv.2009.07.015
Sidhu MK, Ravindra K, Mor S, John S (2017) Household air pollution from various types of rural kitchens and its exposure assessment. Sci Total Environ 586:419–429. https://doi.org/10.1016/j.scitotenv.2017.01.051
Singh A, Jamal S (2012) A study of risk factors associated with indoor air pollution in the low income households in Aligarh city, India. J Environ Res 3(1):1–8. http://www.e3journals.org/JERM
Sudha DK (2000) Gender roles. APH Publishing, Delhi
Taneja A, Saini R, Masih A (2008) Indoor air quality of houses located in the urban environment of Agra, India. Ann N Y Acad Sci 1140(1):228–245. https://doi.org/10.1196/annals.1454.033
Tyagi B, Choudhury G, Vissa NK, Singh J, Tesche M (2021) Changing air pollution scenario during COVID-19: redefining the hotspot regions over India. Environ Pollut 271:116354. https://doi.org/10.1016/j.envpol.2020.116354
WHO (2018) World Health Organization. Retrieved from Household air pollution and health. https://www.who.int/newsroom/fact-sheets/detail/household-air-pollution-and-health. Accessed on 25 Nov 2018
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare no conflict of interest associated with this publication.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Shukla, D., Dutta, V. Indoor Air Quality Monitoring of Urban and Rural Households of a North Indian City During Cooking Hours. Aerosol Sci Eng 6, 86–98 (2022). https://doi.org/10.1007/s41810-021-00126-1
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s41810-021-00126-1