Influence of cryogenic permanent magnet undulator motion error on magnetic field error and radiation intensity loss

  • Review
  • Published:
Radiation Detection Technology and Methods Aims and scope Submit manuscript

Abstract

A cryogenic permanent magnet undulator prototype designed for Chinese High Energy Photon Source Test Facility (HEPS-TF) at Institute of High Energy Physics is constructed and now commissioning. Motion precision of girders is a significant parameter to guarantee gap error so as to avoid phase error and radiation intensity loss. In order to study and minimize girder parallelism errors, RADIA and SPECTRA are used to calculate qualified motion precision. Spring Modules and single motor closed-loop feedback are designed to compensate the errors. Magnetic field is finally tuned to reach specifications. Details of the study and analysis will be presented in this paper.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  1. X. Jiang, J.Q. WANG, Q. QIN et al., Chinese high energy photon source and the test facility. SCIENTIA SINICA Phys. Mech. Astron. 44(10), 1075 (2014)

    Article  Google Scholar 

  2. Toru Hara, Takashi Tanaka, Hideo Kitamura, Cryogenic permanent magnet undulators. Phys. Rev. ST Accel. Beams 7, 050702 (2004)

    Article  ADS  Google Scholar 

  3. Y. Yang, H. Lu, S. Sun et al., Field Error Correction Considerations of Cryogenic Permanent Magnet Undulator (CPMU) for High Energy Photon Source Test Facility (HEPS-TF), in 7th International Particle Accelerator Conference (IPAC’16) (Busan, Korea, 2016), pp. 4038–4040

  4. S. C. Sun and al., Mechanical design of a cryogenic permanent magnet undulator at IHEP, in Proceeding of the IPAC17, 8th International Particle Accelerator Conference (Copenhagen, Denmark, TUPAB066, 2017)

  5. H. H. Lu et al., Development of a PrFeB cryogenic permanent magnet undulator (cpmu) prototype at IHEP, in Proceeding of the IPAC17, 8th International Particle Accelerator Conference (Copenhagen, Denmark, TUPAB064, 2017)

  6. L. Zhang and al., Design of the CPMU Vacuum System at the HEPS, in Proceeding of the IPAC17, 8th International Particle Accelerator Conference (Copenhagen, Denmark, TUPAB068, 2017)

  7. S. Shuchen et al., Research on structure design under cryogenic effect in cryogenic permanent magnet undulator of high energy photon source. Cryogenics Supercond. 12, 11–14 (2017)

    Google Scholar 

  8. C.S. Hwang, Insertion devices: wigglers and undulators. Accel. Phys. Technol. Appl. 489–511 (2014)

  9. S.H. Kim, Magnetic field calculations of a permanent magnet insertion device for the advanced photon source. IEEE Trans. Mag. 1102–1104 (1988)

  10. T. Nonaka, K. Dohmae et al., Quick-scanning x-ray absorption spectroscopy system with a servo-motor-driven channel-cut monochromator with a temporal resolution of 10 ms [J]. Rev. Sci. Instrum. 83, 083112 (2012)

    Article  ADS  Google Scholar 

  11. P. Elleaume and al., Computing 3D magnetic field from insertion devices, in Proc. PAC97, pp. 3509–3511 (1997)

  12. W. Chen, C.T. Shi, H.H. Lu et al., Development of insertion devices measurement system at IHEP. Proc. Fel Shanghai China 20, 55–6 (2011)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shu-Chen Sun.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sun, SC., Sheng, WF., Lu, HH. et al. Influence of cryogenic permanent magnet undulator motion error on magnetic field error and radiation intensity loss. Radiat Detect Technol Methods 2, 29 (2018). https://doi.org/10.1007/s41605-018-0063-1

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s41605-018-0063-1

Keywords

PACS

Navigation