Abstract
We sought to minimize streak artifacts caused by beam hardening on chest CT scan, obtain high-quality CT images and compare image quality and dose between with and without iodine and bismuth shielding material to protect superficial organs. During CT, the radiation dose was measured and the images evaluated before using the shielding material, iodine and bismuth. A body phantom of polymethyl methacrylate (PMMA) measuring 32 cm was used for image quality and radiation dose measurement according to the shielding material of the CT scan. During CT, phantom noise was measured to be 11.49 HU without shielding, 12.95 HU with bismuth, and 14.67 HU with iodine (p > 0.05). Based on the dose, in the absence of the shielding material, the shielding with iodine showed a dose reduction effect of 40.64% at 11 o'clock and 35.74% at 1 o'clock. In the case of bismuth shielding, the dose at 11 o'clock was decreased to 34.06% and the dose at 1 o'clock was decreased to 34.32%. Dose reduction was observed prior to the use of the shielding material and the application of the iodine and bismuth shielding materials (p < 0.05). In phantom chest CT, the dose reduction of the superficial organs using iodine and bismuth, a radiation shielding material, was confirmed.
Similar content being viewed by others
References
D.J. Brenner, E.J. Hall, N. Engl, J. Med. 357, 2277 (2007)
C. Hohl, J.E. Wildberger, C. Süss, C. Thomas, G. Mühlenbruch, T. Schmidt, D. Honnef, R.W. Günther, A.H. Mahnken, Acta. Radiol. 47, 562 (2006)
J. Geleijns, M. Salvadó Artells, W.J. Veldkamp, M. López Tortosa, A. Calzado Cantera, Eur. Radiol. 16, 2334 (2006)
J.R. Curtis, Radiol. Technol. 81, 428 (2010)
T. Henzler, M. Hanley, E. Arnoldi, G. Bastarrika, U.J. Schoepf, H.C. Becker, J. Thorac. Imaging. 25, 213 (2010)
K.D. Hopper, S.H. King, M.E. Lobell, T.R. TenHave, J.S. Weaver, Radiology 205, 853 (1997)
Y.H. Lee, E.T. Park, P.K. Cho, H.S. Seo, B.K. Je, S.I. Suh, Am. J. Roentgenol. 196, 611 (2011)
M.H. Yilmaz, D. Yaşar, S. Albayram, I. Adaletli, H. Ozer, M. Ozbayrak, Eur. J. Radiol. 61, 138 (2007)
M. Mazonakis, A. Tzedakis, J. Damilakis, N. Gourt-soyiannis, Eur. Radiol. 17, 1352 (2007)
Z. Li, W. Zhou, X. Zhang, Y. Gao, S. Guo, Sci. Rep. 11, 4384 (2011)
Mousa, K. Kusminarto, G.B. Suparta, Int. J. Appl. Eng. Res. 12, 10589 (2017)
R.E. Alvarez, A. Macovski, Phys. Med. Biol. 21, 733 (1976)
X. Wang, D. Meier, K. Taguchi, D.J. Wagenaar, B.E. Patt, E.C. Frey, Med. Phys. 38, 1534 (2011)
C.T. Chantler, K. Olsen, R.A. Dragoset, J. Chang, A.R. Kishore, S.A. Kotochigova, D.S. Zucker, NIST, Physical Measurement Laboratory (2005)
M. Bahreyni Toosi, M. Nazery, H. Zare, Iran. J. Radiat. Res. 4, 21 (2006)
W.J. Lee, D.C. Kweon, Radiat. Effects Defects Solids 176, 368 (2021)
Y.H. Seong, J. Korean Phys. Soc. 67, 1 (2015)
D.A. Leswick, M.M. Hunt, S.T. Webster, D.A. Fladeland, Radiology 249, 572 (2008)
M.Y. Jung, D.C. Kweon, S.I. Kwon, J. Radiol. Sci. Technol. 23, 307 (2009)
B.L. Fricke, L.F. Donnelly, D.P. Frush, T. Yoshizumi, V. Varchena, S.A. Poe, J. Lucaya, Am. J. Roentgenol. 180, 407 (2003)
M.H. Yilmaz, S. Albayram, D. Yaşar, H. Ozer, I. Adaletli, D. Selçuk, C. Akman, A. Altuğ, J. Comput. Assist. Tomogr. 31, 138 (2007)
J.E. Ngaile, C.B. Uiso, P. Msaki, R. Kazema, Radiat. Protdosim. 130, 490 (2008)
J. Wang, X. Duan, J.A. Christner, S. Leng, K.L. Grant, C.H. McCollough, Radiology 262, 191 (2012)
J. Wang, X. Duan, J.A. Christner, S. Leng, L. Yu, C.H. McCollough, Med. Phys. 38, 6084 (2011)
P.M. Colletti, O.A. Micheli, K.H. Lee, Am. J. Roentgenol. 200, 503 (2013)
P. Mehnati, R. Malekzadeh, M.Y. Sooteh, Radiol. Phys. Technol. 12, 6 (2019)
J. Wang, X.D. Meier, K. Taguchi, D.J. Wagenaar, B.E. Patt, Med. Phys. 38, 1534 (2011)
D.C. Kweon, B.S. Seo, J.W. Choi, K.R. Dong, W.K. Chung, Radiat. Effects Defects Solids 175, 672 (2020)
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Kweon, D.C., Lee, JW. & Choi, J. Protection of superficial organs using bismuth and iodine shielding during computed tomography in phantoms. J. Korean Phys. Soc. 81, 59–67 (2022). https://doi.org/10.1007/s40042-022-00482-2
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s40042-022-00482-2