Abstract
A very simple method to measure the effect of the backscatter from secondary collimators into the beam monitor chambers in linear accelerators equipped with multi-leaf collimators (MLC) is presented here. The backscatter to the monitor chambers from the upper jaws of the secondary collimator was measured on three beam-matched linacs by means of three methods: this new methodology, the ecliptic method, and assessing the variation of the beam-on time per monitor unit with dose rate feedback disabled. This new methodology was used to assess the backscatter characteristics of asymmetric over-traveling jaws. Excellent agreement between the backscatter values measured using the new methodology introduced here and the ones obtained using the other two methods was established. The experimental values reported here differ by less than 1 % from published data. The sensitivity of this novel technique allowed differences in backscatter due to the same opening of the jaws, when placed at different positions on the beam path, to be resolved. The introduction of the ecliptic method has made the determination of the backscatter to the monitor chambers an easy procedure. The method presented here for machines equipped with MLCs makes the determination of backscatter to the beam monitor chambers even easier, and suitable to characterize linacs equipped with over-traveling asymmetric secondary collimators. This experimental procedure could be simply implemented to fully characterize the backscatter output factor constituent when detailed dosimetric modeling of the machine’s head is required. The methodology proved to be uncomplicated, accurate and suitable for clinical or experimental environments.
Similar content being viewed by others
Notes
Linacs located at CSSSG-Hôpital de Gatineau, Gatineau QC, Canada.
References
Kubo H (1989) Telescopic measurement of backscattered radiation from secondary collimator jaws to a beam monitor chamber using a pair of slits. Med Phys 16:295
Huang PH, Chu J, Bjärngard BE (1987) The effect of collimator backscatter radiation on photon output of linear accelerators. Med Phys 14:268
Liu HH, Mackie TR, McCullough EC (2000) Modeling photon output caused by backscattered radiation into the monitor chamber from collimator jaws using a Monte Carlo technique. Med Phys 27:737
Sanz DE, Alvarez GD, Nelli FE (2007) Ecliptic method for the determination of backscatter into the beam monitor chambers in photon beams of medical accelerators. Phys Med Biol 52:1647
Zhu TC, Ahnesjö A, Lam KL, Li XA, Ma CMC, Palta JR, Sharpe MB, Thomadsen B, Tailor RC (2009) Report of AAPM Therapy Physics Committee Task Group 74: in-air output ratio, Sc, for megavoltage photon beams. Med Phys 36:5261
Cranmer-Sargison G, Weston S, Evans JA, Sidhu NP, Thwaites DI (2011) Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors. Med Phys 38:6592
Ahnesjö A, Knoos T, Montelius A (1992) Application to the convolution method for calculation of output factors for therapy photon beams. Med Phys 19:295
Eclipse algorithms reference guide: chapter 4 photon beam source model, Varian medical systems, Inc. (2011)
Zavgorodni S, Alhakeem E, Townson R (2014) Monitor backscatter factors for the Varian 21EX and TrueBeam linear accelerators: measurements and Monte Carlo modelling. Phys Med Biol 59:911
Yang Y, Xing L, Boyer AL, Song Y, Hu Y (2002) A three-source model for the calculation of head scatter factors. Med Phys 29:2024
Sharpe MB, Jaffray DA, Battista JJ, Munro P (1995) Extrafocal radiation: a unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams. Med Phys 22:2065
Acknowledgments
I would like to thank Dr. Sergei Zavgorodni for kindly giving permission for using the data on backscatter measured by his team and for providing valuable comments on this manuscript. I want to express gratitude also to Ms. Debbie Wright for her valuable help in revising this document, and to my daughters Franca Nelli and Anna Nelli for their collaboration in producing some of the figures used here.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Nelli, F.E. An MLC-based version for the ecliptic method for the determination of backscatter into the beam monitor chambers in photon beams of medical accelerators. Australas Phys Eng Sci Med 39, 221–228 (2016). https://doi.org/10.1007/s13246-015-0413-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13246-015-0413-y