Abstract
Purpose
To present the first results of intraoperative irradiation (IORT) in breast cancer with a low-energy photon system used as partial breast irradiation (PBI) or as an anticipated boost before whole breast hypo-fractionated irradiation (IORT + WBI), concerning tolerance, side effects, quality of life, and patient-reported outcomes.
Materials and methods
Eighty patients treated with an Intrabeam® system of 50 kV X-rays received a 20 Gy dose intraoperatively were included. Moderate daily hypofractionation of 2.7 Gy in 15 fractions up to 40.5 Gy was administered if high-risk factors were present. Acute post-operative toxicity, surgery complications, chronic toxicity, patient-reported cosmesis and Breast-Q questionnaire were performed at follow-up visits.
Results
Thirty-one patients were treated as PBI and the remaining 49 as IORT + WBI. Only the IORT + WBI group presented acute toxicity, mainly mild acute dermatitis (11 patients) and one subacute mastitis. A total of 20 patients presented fibrosis (18 patients grade I, 2 patients grade II), 15 (30.5%) patients in the IORT + WBI group and 3 (9.6%) patients in the group of PBI. The cosmesis evaluation in 73 patients resulted poor, fair, good or excellent in 2, 7, 38 and 26 patients, respectively. In PBI group Breast-Q scored higher, especially in terms of their psychosocial well-being (78 vs 65) and satisfaction with radiation-induced toxicity (77 vs 72, respectively) compared to IORT + WBI group.
Conclusion
IORT is a well-tolerated procedure with low toxicity, good cosmesis and favorable patient-reported outcomes mainly when administered as PBI.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Breast cancer has a high incidence, representing 11.6% of all neoplasms in all countries [1]. The results of randomized studies have shown that conservative surgery and radiotherapy are as effective as mastectomy in terms of local control [2, 3], and conservative treatment even can offer better survival rate [4]. Whole-breast irradiation (WBI) reduces ipsilateral recurrence [5], but can produce skin toxicity and fibrosis, especially when boosting the tumor bed [6]. Accelerated partial breast irradiation (APBI) focuses irradiation only to tumor bed with margin, as recurrences occur more frequently in this area [7] and allows shorter treatment duration while sparing healthy tissue. Several randomized trials comparing APBI to WBI demonstrated similar tumor control after 5 years in selected patients [8]. GEC- ESTRO and ASTRO have provided guidelines for the selection of treatment in patients eligible for APBI [9, 10]. Many APBI techniques have been developed, including brachytherapy [11], external radiation therapy [12], and intraoperative radiation therapy (IORT) [13, 14]. IORT allows an extremely short radiation treatment time during surgery and decreases the hospital visits for adjuvant radiation therapy. Also, direct irradiation of the surgical bed is performed and allows better protection of nearby organs at risk. Moreover, intraoperative radiotherapy can administer tumor boost dose and avoid the geographic miss in patients who require WBI [15].
This article presents the first results of the application of IORT with a 50 kV photon system, both as PBI or as an anticipated boost before hypo-fractionated irradiation (IORT + WBI), concerning tolerance, side effects, quality of life, and acceptance reported by patients.
Materials and methods
Inclusion of patients
Patients evaluated in our breast unit between June 2018 and February 2020 who received IORT were included in the study and distributed in two groups: the PBI group, that, according to ASTRO consensus [10] for partial breast irradiation, comprised patients with infiltrating tumors smaller than 3 cm, grade I or II, no extensive or high-grade intraductal component, free surgical margins, positive hormone receptors, and uninvolved nodes, or also pure intraductal tumors grade I or II less than 2.5 cm, detected by screening mammography; and the IORT + WBI group, comprising cases that did not meet the criteria for exclusive PBI (including age less of 50 years or receiving neoadjuvant treatment) and for who the IORT was complemented with external radiotherapy after surgery or after adjuvant systemic treatment when indicated.
IORT procedure
Patients were given a post-lumpectomy radiation therapy dose before the completion of their surgery using an Intrabeam® system (Carl Zeiss Meditec, Oberkochen, Germany) that utilizes a point source of X-rays of 50 kV energy that provides the dose by means of a spherical applicator that allows effective irradiation at 1–1.5 cm depth. All patients received a 20 Gy dose prescribed at applicator surface. The irradiation time varied depending on the applicator size used and ranged between 17 and 40 min. In Fig. 1 distribution of diameter applicator sized are shown. The chosen applicator was attached to the accelerator and easily inserted into the surgical cavity and held in position by a provisional purse string suture. Irradiation was always carried out with staff remaining outside the operating room. After irradiation, the provisional suture was released, the applicator was withdrawn, and the intervention was completed.
Postoperative evaluation and treatment
In the post-operative evaluation, all patients were visited 3–4 weeks after surgery to determine if additional irradiation was needed based on the pathological result and our hospital guidelines. When necessary, WBI was scheduled after surgery or after chemotherapy-based systemic treatment. In these cases, the breast was irradiated with moderate daily hypofractionation of 2.7 Gy in 15 fractions up to 40.5 Gy total dose.
Follow-up
The follow-up was carried out at 1, 3, 6, 9, and 12 months, evaluating acute post-operative toxicity, surgery complications, chronic toxicity, patient-reported cosmesis, and also the health-related quality of life using the Breast-Q questionnaire designed to reflect the patient's perception of the results of surgery and their degree of satisfaction in different aspects related to the treatment of their breast cancer [16]. The questionnaires were answered one year after the surgery, obtaining a score from 0 to 100 in the different domains included, where a higher value represents a more favorable result. Change of more than 10 points on a scale from 0 to 100 is considered clinically relevant results [17].
Results
Patient and tumor characteristics
A total of 80 patients with early breast cancer treated with IORT were included. Follow-up was between 12 and 28 months (median = 18). The characteristics of the patients were: mean age of 63 years (range 30–86), 63 patients (78.7%) were postmenopausal, 14 (17.5%) were premenopausal and 3 (3.8%) were perimenopausal.
There was a history of previous neoplasia in 13 patients of which 10 were contralateral and 3 were ipsilateral, thus treated at the time of relapse (one without previously receiving radiotherapy after the first conservative treatment). The clinical and pathological characteristics of the included patients are presented in Table 1. The margin after resection was free in all patients. Five patients (4.3%) were treated with neoadjuvant chemotherapy and 18 patients (22.5%) with adjuvant chemotherapy.
Received treatments
Of the patients included in the study, 31 (38.8%) were treated with intraoperative radiotherapy as PBI, without requiring subsequent adjuvant irradiation. The remaining 49 patients (61.3%) received IORT + WBI and in nine patients (11.2%) the lymph node areas were also irradiated.
Postoperative and acute radiation toxicity
Postsurgical seroma occurred in 38 cases, 17 (54.8%) patients in the PBI group, and 21 (42.9%) patients in the IORT + WBI group. Three patients required drainage puncture. The toxicity of the patients who received external radiotherapy is presented in Table 2. Only in the IORT + WBI group acute skin toxicity was reported, mainly mild dermatitis in 11 patients, and one patient presented subacute mastitis at mid-term follow-up.
Chronic toxicity and cosmesis
A total of 20 patients presented fibrosis (18 patients with grade I fibrosis, 2 patients with grade II) distributed as follows: 15 (30.5%) patients in the IORT + WBI group and 3 (9.6%) patients in the PBI group. The cosmesis evaluation in 74 patients resulted in 27, 38, 7, and 2 patients with excellent, good, fair, and poor cosmesis, respectively.
Patient reported outcomes
Of the total patients included, 67 patients (84%) completed the Breast-Q questionnaires, 26 (84%) in the PBI group, and 41 (84%) in the IORT + WBI group. It is noteworthy that patients with PBI reported the highest scores in general, especially in terms of their psychosocial well-being (78 vs 66). and were also more satisfied with radiation-induced toxicity (77 vs 72, respectively). In addition, PBI patients reported better sexual well-being and satisfaction with their surgeon than IORT + WBI patients (75 vs 65, 96 vs 86). Satisfaction with breasts and satisfaction with information were seen without significant difference between IORT + WBI group and PBI group (66 vs 68, 68 vs 70). On the other hand, physical well-being, satisfaction with medical team and satisfaction with office staff in IORT + WBI group performed better (72 vs 66, 94 vs 92, 98 vs 93, respectively), see Fig. 2.
Discussion
PBI techniques and outcomes
APBI has good efficacy in selected patients as shown in several trials. In the Pòlgar study utilizing brachytherapy, were found no differences in local recurrence between WBI and APBI (5.1% vs 5.9%). The APBI patients had significantly fewer moderate to severe late side effects, and excellent cosmetic result [18]. APBI can also be performed by external irradiation [19]. In the RAPID Trial [20], APBI was not inferior to WBI in preventing ipsilateral relapse in node-negative breast cancer. The NSABP B-39/RTOG 0413 trial has confirmed this equivalence and the absolute difference at 10 years was also small (< 1.6%) between arms [21].
IORT rationale and trials
Another alternative to partial irradiation is IORT, a suitable technique which allows small volumes of treatment and skin protection with a positive impact on the late toxicity and cosmesis. In the updated ASTRO consensus and after revision of the published evidence, IORT was included as an option to perform PBI, remarking the need of careful selection of patients to be included outside a clinical trial (“suitable group”) [10]. The radiobiological differences of the available IORT available techniques made difficult their direct comparison.
The first experiences of IORT have been carried out with mobile accelerators that provide irradiation by means of an electron beam. The ELIOT trial included 1305 patients, comparing WBI to PBI with electron IORT. At five years follow-up, the relapse rate was significantly higher in IORT group than in WBI group, and overall survival was not different between the two groups [22]. The improved patient selection allows better results in terms of disease control [23].
More recently, the TARGIT-A trial, using 50 kV X-rays with Intrabeam®, 3451 patients were randomized to receive WBI (1730 patients) or IORT (1721 patients). Wound-related complications were the same between groups, but there was significantly less grade 3 or 4 toxicity related to radiotherapy complications with IORT than with WBI [24]. Also, a better cosmesis result is observed through computer-assisted objective system [25], and overall better quality of life [26]. With a longer follow-up (median 8.6 years, maximum 18.9 years), no statistically significant differences were found for local recurrence-free survival (hazard ratio 1.13; 95% CI 0.91–1.41; p = 0.28) [27], but there were significantly fewer deaths in the IORT group than in the WBI group, attributable to fewer deaths from cardiovascular causes and other cancers.
In our study patients submitted to intraoperative PBI resulted in an excellent tolerance and mild toxicity. The main secondary effect was seroma presented in half of the series but in the majority of cases was resolved without treatment. Only 9.6% of patients present mild fibrosis and the cosmetic results is good or excellent in 96% of cases.
IORT + WBI
In addition, IORT is also an option for performing an anticipated tumor bed boost [28]. Fastner et al. [29] published the results of IORT with electrons as a boost and showed that reduce recurrence in breast cancer, with only 16 (0.8%) recurrences observed in the breast (p = 0.031). A randomized case III trial comparing 10 Gy IORT as a boost with WBI and external irradiation boost at standard fractionation demonstrated iso-efficacy of both arms while obtaining better cosmetic results in IORT boost arm [30]. In HIOB trial combining electron IORT and hypo-fractionated WBI the tolerance was excellent and cosmesis appearance was not altered after 3 years evaluation [31]. Our results in the group of IORT + WBI have shown acute dermatitis after hypo-fractionated WBI and a discrete trend to higher fibrosis and less favorable cosmesis but comparable to standard fractionation schedules after IORT.
Patient-reported outcomes
There is little research about patient-reported outcomes in the setting of IORT. Patients in TARGIT A trial tended to self-report better outcomes for breast-related quality of life (QOL), and they experienced fewer symptoms and better results in breast-related QOL [32]. In our series, the PBI patients have overall higher scores in the quality of life and satisfaction tests, recover their psychosocial well-being earlier, and have a lower perception of radiotherapy adverse effects. However, they show poorer scores on the physical well-being scale, which could be partially explained by the slightly older age of patients selected for PBI. In terms of patient comfort, IORT prolongs the surgical procedure for only an additional short period but, dramatically shortens, or in selected cases perhaps even replaces, post-operative radiation therapy. In patients with IORT + WBI it seems to have no impact of hypo-fractionated irradiation at well-being evaluations.
Conclusions
According to our study, IORT shows low toxicity, good cosmesis, and good quality of life for patients. When administered as an anticipated boost, prior to hypo-fractionated WBI there is a trend towards greater toxicity, but the cosmesis results remain quite good and comparable to those reported in the literature.
Availability of data and materials
All data are available for analysis and review in electronic records.
References
Wild CP, Weiderpass E, Stewart BW. World Cancer Report: Cancer Research for Cancer Prevention. Lyon, France: International Agency for Research on Cancer. 2020. http://publications.iarc.fr/586. Accessed 1 May 2021.
Fisher B, Anderson S, Bryant J, Margolese RG, et al. Twenty-year follow-up of a randomized trial comparing total mastectomy, lumpectomy and lumpectomy plus irradiation for the treatment of invasive breast cancer. New Eng J Med. 2002;16:1233–41. https://doi.org/10.1056/NEJMoa022152.
Veronesi U, Cascinelli N, Mariani L, Marco G, et al. Twenty-year follow-up of a randomized study comparing breast-conserving surgery with radical mastectomy for early breast cancer. N Engl J Med. 2002;16:1227–32. https://doi.org/10.1056/NEJMoa020989.
Almahariq M, Quinn T, Siddiqui Z, et al. Breast conserving therapy is associated with improved overall survival compared to mastectomy in early-stage, lymph node-negative breast cancer. Radiother Oncol. 2020;142:186–94. https://doi.org/10.1016/j.radonc.2019.09.018.
Fisher ER, Anderson S, Redmond C, Fisher B. Ipsilateral breast tumor recurrence and survival following lumpectomy and irradiation: pathological findings from NSABP protocol B-06. Semin Surg Oncol. 1992;8:161–6.
Barteling H, Maignon P, Poortmans P, et al. Whole-breast irradiation with or without a boost for patients treated with breast-conserving surgery for early breast cancer: 20-year follow-up of a randomised phase 3 trial. Lancet Oncol. 2015;16(1):47–56. https://doi.org/10.1016/S1470-2045(14)71156-8.
Holland R, Veling SHJ, Mravunac M, et al. Histologic multifocality of Tis, T1–2 breast carcinomas: implications for clinical trials of breast-conserving surgery. Cancer. 1985;56:979–90. https://doi.org/10.1002/1097-0142(19850901)56:5%3c979::aid-cncr2820560502%3e3.0.co;2-n.
Livi L, Meattini I, Marrazzo L, et al. Accelerated partial breast irradiation using intensity-modulated radiotherapy versus whole breast irradiation: 5-year survival analysis of a phase 3 randomised controlled trial. Eur J Cancer. 2015;51(4):451–63. https://doi.org/10.1016/j.ejca.2014.12.013.
Polgar C, Van Limbergen E, Potter R, et al. Patient selection for accelerated partial-breast irradiation (APBI) after breast conserving surgery: recommendations of the Groupe European de Curie therapy-European Society for Therapy Radiology and Oncology (GEC-ESTRO) breast cancer working group based on clinical evidence (2009). Radiother Oncol. 2010;94(3):264–73. https://doi.org/10.1016/j.radonc.2010.01.014.
Correa C, Harris EE, Leonardi MC, et al. Accelerated partial breast irradiation: executive summary for the update of ASTRO evidence-based consensus statement. Pract Radiat Oncol. 2017;7(2):73–9. https://doi.org/10.1016/j.prro.2016.09.007.
Strnad V, Ott OJ, Hildebrandt G, et al. 5-year results of accelerated partial breast irradiation using sole interstitial multicatheter brachytherapy versus whole-breast irradiation with boost after breast-conserving surgery for low-risk invasive and in situ carcinoma of the female breast: a randomised, phase 3, non-inferiority trial. Lancet. 2016;387(10015):229–38. https://doi.org/10.1016/S01406736(15)00471-7.
Mozsa E, Meszaros N, Major T, et al. Accelerated partial breast irradiation with external beam three-dimensional conformal radiotherapy. Five-year results of a prospective phase II clinical study. Strahlenther Onkol. 2014;190(5):444–50. https://doi.org/10.1007/s00066-014-0633-1.
Holmes DR. Intraoperative radiotherapy in breast conserving surgery. J Surg Oncol. 2014;110(1):68–74. https://doi.org/10.1002/jso.23620.
Veronesi U, Orecchia R, Luini A, et al. Full-dose intraoperative radiotherapy with electrons during breast-conserving surgery: experience with 590 cases. Ann Surg. 2005;242(1):101–6. https://doi.org/10.1097/01.sla.0000167927.82353.bc.
Kaiser J, Kronberger C, Moder A, et al. Intraoperative tumor bed boost with electrons in breast cancer of clinical stages I through III: updated 10-year results. Int J Radiat Oncol Biol Phys. 2018;102(1):92–101. https://doi.org/10.1016/j.ijrobp.2018.05.028.
Pusic AL, Klassen AF, Scott AM, et al. Development of a new patient-reported outcome measure for breast surgery: the BREAST-Q. Plast Reconstr Surg. 2009;124(2):345–53. https://doi.org/10.1097/PRS.0b013e3181aee807.
Osoba D, Rodrigues G, Myles J, Zee B, Pater J. Interpreting the significance of changes in health-related quality-of-life scores. J Clin Oncol. 1998;16:139–44. https://doi.org/10.1200/JCO.1998.16.1.139.
Polgár C, Ott OJ, Hildebrandt G, et al. Late side-effects and cosmetic results of accelerated partial breast irradiation with interstitial brachytherapy versus whole-breast irradiation after breast-conserving surgery for low-risk invasive and in-situ carcinoma of the female breast: 5-year results of a randomised, controlled, phase 3 trial. Lancet Oncol. 2017;18(2):259–68. https://doi.org/10.1016/S1470-2045(17)30011-6.
Rodríguez N, Sanz X, Dengra J, Foro P, Membrive I, Anna R, Quera JQ, Fernández VE, Pera O, Lio J, Lozano J, Algara M. Five-year outcomes, cosmesis, and toxicity with 3-dimensional conformal external beam radiation therapy to deliver accelerated partial breast irradiation. Int J Radiat Oncol Biol Phys. 2013;87(5):1051–7. https://doi.org/10.1016/j.ijrobp.2013.08.046.
Whelan TJ, Julian JA, Berrang TS, et al. External beam accelerated partial breast irradiation versus whole breast irradiation after breast conserving surgery in women with ductal carcinoma in situ and node-negative breast cancer (RAPID): a randomized controlled trial. Lancet. 2019;394(10215):2165–72. https://doi.org/10.1016/S0140-6736(19)32515-2.
Vicini FA, Cecchini RS, White JR, et al. Long-term primary results of accelerated partial breast irradiation after breast-conserving surgery for early-stage breast cancer: a randomised, phase 3, equivalence trial. Lancet. 2019;394(10215):2155–64. https://doi.org/10.1016/S0140-6736(19)32514-0.
Veronesi U, Orecchia R, Maisonneuve P, et al. Intraoperative radiotherapy versus external radiotherapy for early breast cancer (ELIOT): a randomised controlled equivalence trial. Lancet Oncol. 2013;14(13):1269–77. https://doi.org/10.1016/S1470-2045(13)70497-2.
Veronesi U, Orecchia R, Luini A, et al. Intraoperative radiotherapy during breast conserving surgery: a study on 1,822 cases treated with electrons. Breast Cancer Res Treat. 2010;124(1):141–51. https://doi.org/10.1007/s10549-010-1115-5.
Vaidya JS, Wenz F, Bulsara M, et al. Risk-adapted targeted intraoperative radiotherapy versus whole-breast radiotherapy for breast cancer: 5-year results for local control and overall survival from the TARGIT-A randomised trial. Lancet. 2014;383:603–13. https://doi.org/10.1016/S0140-6736(13)61950-9.
Corica T, Nowak AK, Saunders CM, et al. Cosmetic outcome as rated by patients, doctors, nurses and BCCT.core software assessed over 5 years in a subset of patients in the TARGIT-A Trial. Radiat Oncol. 2018;13:68–77. https://doi.org/10.1186/s13014-018-0998-x.
Welzel G, Boch A, Sperk E, et al. Radiation-related quality of life parameters after targeted intraoperative radiotherapy versus whole breast radiotherapy in patients with breast cancer: results from the randomized phase III trial TARGIT-A. Radiat Oncol. 2013;8:9. https://doi.org/10.1186/1748-717X-8-9.
Vaidya JS, Bulsara M, Baum M, et al. Long term survival and local control outcomes from single dose targeted intraoperative radiotherapy during lumpectomy (TARGIT-IORT) for early breast cancer: TARGIT-A randomised clinical trial. BMJ. 2020;370:m2836. https://doi.org/10.1136/bmj.m2836.
Sedlmayer F, Reitsamer R, Wenz F, et al. Intraoperative radiotherapy (IORT) as boost in breast cancer. Radiat Oncol. 2017;12:23. https://doi.org/10.1186/s13014-016-0749-9.
Fastner G, Sedlmayer F, Merz F, et al. IORT with electrons as boost strategy during breast conserving therapy in limited stage breast cancer: long term results of an ISIORT pooled analysis. Radiother Oncol. 2013;108(2):279–86. https://doi.org/10.1016/j.radonc.2013.05.031.
Ciabattoni A, Gregucci F, Fastner G, et al. IOERT versus external beam electrons for boost radiotherapy in stage I/II breast cancer: 10-year results of a phase III randomized study. Breast Cancer Res. 2021;23(1):46. https://doi.org/10.1186/s13058-021-01424-9.
Fastner G, Reitsamer R, Urban B, et al. Toxicity and cosmetic outcome after hypofractionated whole breast irradiation and boost-IOERT in early stage breast cancer (HIOB): First results of a prospective multicenter trial (NCT 01343459). Radiother Oncol. 2020;146:136–42. https://doi.org/10.1016/j.radonc.2020.02.001.
Corica T, Nowak A, Saunders C, et al. Cosmesis and breast-related quality of life outcomes following intra-operative radiotherapy for early breast cancer: a sub-study of the TARGIT-A trial. Int J Radiat Oncol Biol Phys. 2016;96(1):55–64. https://doi.org/10.1016/j.ijrobp.2016.04.024.
Funding
Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
All authors declare they have no conflict of interest except Dr Algara that has received consulting honoraria from Sysmex and Aristo and speaking honoraria from Siemens and Roche.
Ethical approval
This study has been approved by our institutional review ethics board and is in accordance to ethical standards of 1964 Helsinki Declaration for medical research.
Consent to participate
All patients included signed informed consent to the participation in the study.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Li, X., Sanz, J., Argudo, N. et al. Intraoperative irradiation in breast cancer: preliminary results in 80 patients as partial breast irradiation or anticipated boost prior to hypo-fractionated whole breast irradiation. Clin Transl Oncol 24, 829–835 (2022). https://doi.org/10.1007/s12094-021-02728-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12094-021-02728-0