Abstract
When exposed to air, coal catches fire due to self-oxidation. Coal mine fire is one of the major sources of particulate matter (PM) emissions in coal mining areas. Coal mine is widespread in India with Jharia Coalfield having a number of coal seams and coal dumps under fire. The understanding of magnitude and character of particulate matter emitted from coal mine fire areas is important in order to understand its health impacts, about which not many studies have been carried out. The paper presents findings of a study aimed to characterize physical and chemical properties of airborne respirable particle (PM10) in the fire-affected area at Jharia Coalfield, India. The study was carried out for a period of 8 months from October 2011 to June 2012. The mean concentrations of PM10 were 338.0, 369.0, and 357.0 μg m−3 during summer, winter, and post-monsoon, respectively. Scanning electron microscopy (SEM) showed the presence of rounded, spherical, and oval formed particulate in ambient air that is characteristics of combustion sources. Dominance of irregular-shaped particulate in all samples indicated road dust as the source. Abundance of fine PM (<4 mm) indicated burning process to be the source. For the “qualitative analysis,” techniques like Fourier transform infrared (FTIR) spectroscopy, gas chromatography–mass spectrometry (GC-MS), and inductively coupled plasma optical emission spectrometry (ICP-OES) were used. Chemical analysis shows the presence of elements like Fe, Al, Cu, Si, Na, Cr, Mn, Zn, Cd, Ni, K, and Pb. Anionic concentrations of SO4 2−, NO3 −,Cl−, F−, and PO4 2− were analyzed using ion chromatography. Carbonaceous aerosol analysis results indicated that concentrations of carbonaceous species were 19.51 μg m−3 for organic carbon (OC) and 238.0 μg m−3 for elemental carbon (EC) in PM10 samples.
Similar content being viewed by others
References
APHA (1977) Standard methods for the examination of water and wastewater. American Public Health Association
Berry IG (1974) Selected powder diffraction data for mineralogy, joint committee on powder diffraction standards, & American society for testing and materials. Swanthmore, Pennsylvaina
Bharat Coking Coal limited (BCCL): Master Plan for dealing with fire, subsidence and rehabilitation in the leasehold of BCCL. Central Mine Planning & Design Institute Ltd Regional Institute – 2 Dhanbad (2008). Accessed 25 February 2015
Borai EH, El-Sofany EA, Abdel-Halim AS (2002) Speciation of hexavalent Chromium in atmospheric particulate samples by selective extraction and ion chromatographic determination. Trends Anal Chem 21:741–745
Cole CF, Zapert JG (1995) Air Quality Dispersion Model Validation at Three Stone Quarries. National Stone Association, Washington, D.C. 14884
CPCB (2009) National Ambient Air Quality Standards (NAAQS). Central Pollution Control Board, India
Das BK, Mandal SM, Bhattacharya J (2012) Understanding of the biochemical events in a chemo-bioreactor during continuous acid mine drainage treatment. Environ Earth Sci 66:607–614
Gautam S, Patra AK (2015) Dispersion of particulate matter generated at higher depths in opencast mines. Environ Techol Innov 3:11–27
Ghose MK, Majee SR (2007) Characteristics of hazardous airborne dust around an indian surface coal mining area. Environ Monit Assess 130:17–25
Hystad P, Paul JV, Mark SG, Crouse DL, Johnson K (2015) Canadian Cancer Registries Epidemiology Research Group: Exposure to traffic-related air pollution and the risk of developing breast cancer among women in eight Canadian provinces: a case–control study. Environ Int 74:240–248
Janssen NA, Gerlofs-Nijland ME, Lanki T, Salonen RO, Cassee F, Hoek G, Fischer P, Brunekreef B, Krzyzanowski M (2012) Health effects of black carbon. World Health Organization, Copenhagen
Jones T, Blackmore P, Leach M, Berube K, Sexton K, Richards R (2002) Characterisation of airborne particles collected within and proximal to an opencast coalmine: South Wales, U.K. Environ. Monit Assess 75:293–312
Khillare PS, Sarkar S (2012) Airborne inhalable metals in residential areas of Delhi, India: distribution, source apportionment and health risks. Atmos Pollut Res 3:46–54
Kocbach A, Johansen BV, Schwartz PE, Namork E (2005) Analytical electron microscopy of combustion particles: a comparison of vehicle exhaust and wood smoke. Sci Tot Environ 346:231–243
Li W, Shao L, Wang Z, Shen R, Yang S, Tang U (2010) Size, composition, and mixing state of individual aerosol particles in a south China coastal city. J Environ Sci 22(4):561–569
Li-ding C (1999) Environmental problems in a coal mining area affected by coal fires – A case study in Ruqigou Coalfield, Ningxia, China. J Environ Sci 11(1):23–32
Lippmann M (2012) Particulate matter (PM) air pollution and health: regulatory and policy implications. Air Qual Atmos Health 5:237–241
Martinelli N, Olivieri O, Girelli D (2013) Air particulate matter and cardiovascular disease: a narrative review. Eur J Intern Med 24(4):295–302
Pachauri T, Singla V, Satsangi A, Lakhani A, MaharajKumari K (2013) SEM-EDX Characterization of Individual Coarse Particles in Agra, India. Aerosol Air Qual Res 13(2):523–536
Pandey B, Agrawal M, Singh S (2014) Assessment of air pollution around coal mining area: emphasizing on spatial distributions, seasonal variations and heavy metals, using cluster and principal component analysis. Atmos Pollut Res 5:79–86
Park M, Luo S, Kwon J, Stock TH, Delclos G, Kim H, Yun-Chul H (2013) Effects of air pollution on asthma hospitalization rates in different age groups in metropolitan cities of Korea. Air Qual Atmos Health 6:543–551
Pipal AS, Satsangi GP (2015) Study of carbonaceous species, morphology and sources of fine (PM2.5) and coarse (PM10) particles along with their climatic nature in India. Atmos Res 154:103–115
Pipal AS, Kulshrestha A, Taneja A (2011) Characterization and morphological analysis of airborne PM2.5 and PM10 in Agra located in North Central India. Atmos Environ 45:3621–3630
Pipal AS, Jan R, Satsangi PG, Tiwari S, Taneja A (2014) Study of surface morphology, elemental composition and origin of atmospheric aerosols (PM2.5 and PM10) over Agra, India. Aerosol Air Qual Res 14:1685–1700
Pitts BJF, Pitts Jr. JN (2000) Chemistry of the Upper and Lower Atmosphere. In: Finlayson-Pitts BJ, Pitts JN (eds) Academic Press, San Diego. ISBN 9780122570605, http://dx.doi.org/10.1016/B978-012257060-5/50000-9
Prabha J, Singh G, Sinha IN (2006) Emission factor equation for haul roads: the Indian perspective. Ind J Air Pollut Control 1:37–43
Querol X, Alastuey A, Lopez-Soler A, Mantilla E, Plana F (1996) Mineralogy of atmospheric particles around a large coal- fire power station. Atmos Environ 30:3557–3571
Ragosta M, Caggiano R, D’Emilio M, Sabia S, Trippetta S, Macchiato M (2006) PM10 and heavy metal measurements in an industrial area of southern Italy. Atmos Res 81:304–319
Rengarajan R, Sarin MM, Sudheer AK (2007) Carbonaceous and inorganic species in atmospheric aerosols during wintertime over urban and high-altitude sites in North India. J GeophysRes 112, D21307. doi:10.1029/2006JD008150
Rout TK, Masto RE, Ram LC (2012) Assessment of human health risks from heavy metals in outdoor dust samples in a coal mining area. Environ Geochem Health. doi:10.1007/s10653-012-9499-2
Senthilkumar R (2014) Characterization of minerals in air dust particles in the state of Tamilnadu, India through FTIR, XRD and SEM analysis. Infrared Phys Technol 67:30–41
Shaka H, Saliba NA (2004) Concentration measurements and chemical composition of p M10–2.5 and PM2.5 at a coastal site in Beirut, Lebanon. Atmos Environ 38:523–531
Sinha S, Roy D, Singh G (2012) Assessment and impact of air pollution in Patherdih Coal Washery, Jharia coalfield, Eastern India. Ind Min Eng 53(1):22–30
Tripathy DP, Panigrahi DC, Singh G (2009) Determination of soil pollution index and soil infiltration rates in some non-fire and fire areas of Jharia coalfield.IXth International mine ventilation congress New Delhi, India 10–13
Tsiouri V, Kakosimos KE, Kumar P (2015) Concentrations, sources and exposure risks associated with particulate matter in the Middle East Area—a review. Air QualAtmos Health 8:67–80
World Health Organization (WHO) (2005) WHO Air Quality Guidelines Global Update, World Health Organization, Geneva, 496 http://www.euro.who.int/__data/assets/pdf_file/0005/78638/E90038.pdf. Accessed 24 Feb 2015
Xie RK, Seip HM, Leinum JR, Winje T, Xiao JS (2004) Chemical characterization of individual particles (PM10) from ambient air in Guiyang city, China. Sci Total Environ 343:261–272
Yousefli S (2011) Analyzing the causes of blistering in sintered iron parts: a case study in the Iran powder metallurgy complex. Powder Metall Progress 1:149–152
Zhang X, Chen W, Ma C, Zhan S (2013) Modeling particulate matter emissions during mineral loading process under weak wind simulation. Sci Tot Environ 449:168–173
Acknowledgments
The authors would like to express their special gratitude to Indian School of Mines, Dhanbad (India), for providing all necessary facilities and conducting field work required for this work.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Roy, D., Gautam, S., Singh, P. et al. Carbonaceous species and physicochemical characteristics of PM10 in coal mine fire area—a case study. Air Qual Atmos Health 9, 429–437 (2016). https://doi.org/10.1007/s11869-015-0355-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11869-015-0355-2