Internal fixation devices, and specifically bone plate and screw assemblies, are among the most common implantable medical devices that a failure analyst may encounter. These devices most often fracture by fatigue crack initiation and growth. This article discusses potential root causes of internal fixation device fractures and describes the process of metallurgical and nondestructive examination of these assemblies. Two fractured internal fixation device case studies are reviewed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Source: ASM Handbook Vol. 23 [2]

Fig. 2

Source: ASM Handbook Vol. 23 [2]

Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14

Similar content being viewed by others

References

  1. O. Pohler, in Failures of Orthopedic Implants, ASM Handbook, Failure Analysis and Prevention, vol. 11, 9th edn, ed. by W. T. Becker, R.J. Shipley (ASM International, Metals Park, 1986), pp. 670–694

  2. B. A. James, in Medical Device Failure Analysis, ASM Handbook, Materials for Medical Devices, vol. 23, 1st edn. ed by R. Narayan (ASM International, Metals Park, 2012), p. 343–359

  3. Standard Specification and Test Method for Metallic Bone Plates. ASTM F 382-14, ASTM Volume 13.01 Medical and Surgical Materials and Devices (I)

  4. S. Koh, R.P. Morris, R.M. Patterson, J.P. Kearney, W.L. Buford Jr., S.F. Viegas, Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study. J. Hand Surg. Am. 31(5), 771–779 (2006)

    Article  Google Scholar 

  5. M.L. Villarraga, in Clinical Performance of Rods, Plates, Screws and Cages, Spine Technology Handbook, 1st edn. ed by S.M. Kurtz, A.A. Edidin (Elsevier, New York, 2006), pp. 209–240

  6. L.D. Zardiackas, L.D. Dillon, in Failure Analysis of Metallic Orthopedic Devices, Encyclopedic Handbook of Biomaterials and Bioengineering Part B: Applications, vol. 1, 1st edn. ed by D.L. Wise, D.J. Trantolo, D.E. Altobelli, M.J. Yaszernski, J.D. Gresser, E.R. Schwartz (CRC Press, New York, 1995), pp. 123–170

  7. H.K. Uhthoff, P. Poitras, D.S. Backman, Internal plate fixation of fractures: short history and recent developments. J. Orthop. Sci. 11(2), 118–126 (2006)

    Article  Google Scholar 

  8. S. Lovald, S. Kurtz, Applications of polyetheretherketone in trauma, arthroscopy, and cranial defect repair, in PEEK Biomaterials Handbook, 1st edn., ed. by S. Kurtz (Elsevier, New York, 2012), pp. 243–260

    Chapter  Google Scholar 

  9. S.M. Perren, Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J. Bone Joint Surg. Br. 84(8), 1093–1110 (2002)

    Article  Google Scholar 

  10. http://www.cdc.gov/healthyweight/assessing/bmi/Index.html

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ryan P. Birringer.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Birringer, R.P., Ganot, G.S. & James, B.A. Failure Analysis of Internal Fixation Medical Devices: Overview and Case Studies. J Fail. Anal. and Preven. 16, 849–857 (2016). https://doi.org/10.1007/s11668-016-0159-1

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11668-016-0159-1

Keywords

Navigation