Quantification of Myocardial Perfusion Defect Size in Rats: Comparison between Quantitative Perfusion SPECT and Autoradiography

  • Research Article
  • Published:
Molecular Imaging and Biology Aims and scope Submit manuscript

Abstract

Purpose

Ultra-high resolution single-photon emission computed tomography (SPECT) system, using multiple pinhole collimators, has been applied to the imaging of small rodents. We aimed to compare the myocardial infarction (MI) area on quantitative perfusion single-photon emission computed tomography (QPS; Cedars-Sinai Medical Center, USA) with that on high-resolution autoradiography in rat model to determine the accuracy of perfusion defect measurement by QPS.

Procedures

After thoracotomy, rats (n = 9) had their left coronary arteries occluded and reperfused before injection with 185 MBq [99mTc] methoxyisobutylisonitrile ([99mTc]MIBI) for SPECT and autoradiography. Healthy rats (n = 28) were similarly scanned to create a normal database on which to base QPS. The MI area on SPECT images was analysed automatically by QPS software. For the autoradiography images, regions of interest for MI were set at 1 mm intervals.

Results

In normal rats, [99mTc]MIBI accumulated throughout the left ventricles, and a polar map of ventricular perfusion showed the lowest and highest uptakes in the inferior (68 % ± 4 %) and anterior (92 % ± 5 %) walls, respectively. In the rat MI model, the percentage of polar map with reduced [99mTc]MIBI uptake correlated strongly with the percentage of left ventricle with MI on autoradiography (r2 = 0.90).

Conclusions

QPS can quantitatively evaluate MI severity on myocardial perfusion images in rats, with comparable results to autoradiography. This widely available software could promote the development of new techniques for analysing cardiac images in small animals.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Taki J, Wakabayashi H, Inaki A, Imanaka-Yoshida K, Hiroe M, Ogawa K, Morooka M, Kubota K, Shiba K, Yoshida T, Kinuya S (2013) 14C-methionine uptake as a potential marker of inflammatory processes after myocardial ischemia and reperfusion. J Nucl Med 54(3):431–437. https://doi.org/10.2967/jnumed.112.112060

    Article  PubMed  CAS  Google Scholar 

  2. Taki J, Inaki A, Wakabayashi H, Imanaka-Yoshida K, Ogawa K, Hiroe M, Shiba K, Yoshida T, Kinuya S (2010) Dynamic expression of tenascin-C after myocardial ischemia and reperfusion assessment by 125I-anti-tenascin-C antibody imaging. J Nucl Med 51(7):1116–1123. https://doi.org/10.2967/jnumed.109.071340

    Article  PubMed  CAS  Google Scholar 

  3. van der Have F, Vastenhouw B, Ramakers RM, Branderhorst W, Krah JO, Ji C, Staelens SG, Beekman FJ (2009) U-SPECT-II : an ultra-high-resolution device for molecular small-animal imaging. J Nucl Med 50(4):599–606. https://doi.org/10.2967/jnumed.108.056606

    Article  PubMed  Google Scholar 

  4. Golestani R, Wu C, Tio RA, Zeebregts CJ, Petrov AD, Beekman FJ, Dierckx RAJO, Boersma HH, Slart RHJA (2010) Small-animal SPECT and SPECT / CT : application in cardiovascular research. Eur J Nucl Med Mol Imaging 37(9):1766–1777. https://doi.org/10.1007/s00259-009-1321-8

    Article  PubMed  PubMed Central  Google Scholar 

  5. Go V, Bhatt MR, Hendel RC (2004) The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging. J Nucl Med 45:912–922

    PubMed  Google Scholar 

  6. Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, Pohost GM, Williams KA, American College of Cardiology Foundation Appropriate Use Criteria Task Force, American Society of Nuclear Cardiology, American College of Radiology, American Heart Association, American Society of Echocardiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, Society of Nuclear Medicine (2009) APPROPRIATE USE CRITERIA ACCF / ASNC / ACR / AHA / ASE / SCCT / SCMR / SNM 2009 Appropriate Use Criteria for Cardiac Radionuclide Imaging. J Am Coll Cardiol 53(23):2201–2229. https://doi.org/10.1016/j.jacc.2009.02.013

    Article  PubMed  Google Scholar 

  7. Hachamovitch R, Berman DS, Shaw LJ, Kiat H, Cohen I, Cabico JA, Friedman J, Diamond GA (1998) Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death differential stratification for risk of cardiac death and myocardial infarction. Circulation 97(6):535–544. https://doi.org/10.1161/01.CIR.97.6.535

    Article  PubMed  CAS  Google Scholar 

  8. Sharir T, Germano G, Kang X et al (2001) Prediction of myocardial infarction versus cardiac death by gated myocardial perfusion SPECT: risk stratification by the amount of stress-induced ischemia and the poststress ejection fraction. J Nucl Med 42:831–838

    PubMed  CAS  Google Scholar 

  9. Germano G, Kavanagh PB, Slomka PJ et al (2007) Quantitation in gated perfusion SPECT imaging : the cedars-sinai approach. J Nucl Cardiol 14(4):433–454. https://doi.org/10.1016/j.nuclcard.2007.06.008

    Article  PubMed  Google Scholar 

  10. Strydhorst JH, Leenen FH, Ruddy TD, Wells RG (2011) Reproducibility of serial left ventricle perfusion, volume, and ejection fraction measurements using multiplexed multipinhole SPECT in healthy rats and rats after myocardial infarction. J Nucl Med 52(8):1285–1293. https://doi.org/10.2967/jnumed.111.088658

    Article  PubMed  Google Scholar 

  11. Vanhove C, Lahoutte T, Defrise M, Bossuyt A, Franken PR (2005) Reproducibility of left ventricular volume and ejection fraction measurements in rat using pinhole gated SPECT. Eur J Nucl Med Mol Imaging 32(2):211–220. https://doi.org/10.1007/s00259-004-1649-z

    Article  PubMed  Google Scholar 

  12. Lahoutte T (2007) Monitoring left ventricular function in small animals. J Nucl Cardiol 14(3):371–379. https://doi.org/10.1016/j.nuclcard.2007.04.014

    Article  PubMed  Google Scholar 

  13. Constantinesco A, Choquet P, Monassier L, Israel-Jost V, Mertz L (2005) Assessment of left ventricular perfusion, volumes, and motion in mice using pinhole gated SPECT. J Nucl Med 46(6):1005–1011

    PubMed  Google Scholar 

  14. Roelants V, Delgaudine M, Walrand S, Lhommel R, Beguin Y, Jamar F, Vanoverschelde JL (2012) Myocardial infarct size quantification in mice by SPECT using a novel algorithm independent of a normal perfusion database. EJNMMI Res 2(1):64. https://doi.org/10.1186/2191-219X-2-64

    Article  PubMed  PubMed Central  Google Scholar 

  15. Branderhorst W, Vastenhouw B, Beekman FJ (2010) Pixel-based subsets for rapid multi-pinhole SPECT reconstruction. Phys Med Biol 55(7):2023–2034. https://doi.org/10.1088/0031-9155/55/7/015

    Article  PubMed  Google Scholar 

  16. Miwa K, Inubushi M, Takeuchi Y, Katafuchi T, Koizumi M, Saga T, Sasaki M (2015) Performance characteristics of a novel clustered multi-pinhole technology for simultaneous high-resolution SPECT / PET. Ann Nucl Med 29(5):460–466. https://doi.org/10.1007/s12149-015-0966-6

    Article  PubMed  CAS  Google Scholar 

  17. Slomka PJ, Nishina H, Berman DS et al (2004) Automatic quantification of myocardial perfusion stress-rest change : a new measure of ischemia. J Nucl Med 45:183–192

    PubMed  Google Scholar 

  18. Milavelts JJ, Miller TD, Hodge DO et al (1998) Accuracy of single-photon emission computed tomography myocardial perfusion imaging in patients with stents in native coronary arteries. Am J Cardiol 82:857–861

    Article  Google Scholar 

  19. Amanullah AM, Kita H, Friedman JD et al (1996) Adenosine Technetium-99 m Sestamibi myocardial perfusion SPECT in women: diagnostic efficacy in detection of coronary artery disease. J Am Coll Cardiol 27(4):803–809. https://doi.org/10.1016/0735-1097(95)00550-1

    Article  PubMed  CAS  Google Scholar 

  20. Liu Z, Kastis GA, Stevenson GD, Barrett HH, Furenlid LR, Kupinski MA, Patton DD, Wilson DW (2002) Quantitative analysis of acute myocardial infarct in rat hearts with ischemia-reperfusion using a high-resolution stationary SPECT system. J Nucl Med 43(7):933–939

    PubMed  PubMed Central  Google Scholar 

  21. Acton PD, Thomas D, Zhou R (2006) Quantitative imaging of myocardial infarct in rats with high resolution pinhole SPECT. Int J Cardiovasc Imaging 22(3-4):429–434. https://doi.org/10.1007/s10554-005-9046-7

    Article  PubMed  PubMed Central  Google Scholar 

  22. Wu MC, Gao DW, Sievers RE, Lee RJ, Hasegawa BH, Dae MW (2003) Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice. J Am Coll of Cardiol 42(3):576–582. https://doi.org/10.1016/S0735-1097(03)00716-2

    Article  Google Scholar 

  23. Vrachimis A, Hermann A, Máthé D et al (2012) Systemic evaluation of 99mTc-tetrofosmin versus 99mTc-sestamibi to study murine myocardial perfusion in small animal SPECT/CT. EJNMMI Res 2(1):21. https://doi.org/10.1186/2191-219X-2-21

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  24. Wu C, van der Have F, Vastenhouw B, Dierckx RAJO, Paans AMJ, Beekman FJ (2010) Absolute quantitative total-body small-animal SPECT with focusing pinholes. Eur J Nucl Med Mol Imaging 37(11):2127–2135. https://doi.org/10.1007/s00259-010-1519-9

    Article  PubMed  PubMed Central  Google Scholar 

  25. Taki J, Higuchi T, Kawashima A, Tait JF, Muramori A, Matsunari I, Nakajima K, Vanderheyden JL, Strauss HW (2007) 99mTc-Annexine-V uptake in a rat model of variable ischemic severity and reperfuision time. Cir J 71(7):1141–1146. https://doi.org/10.1253/circj.71.1141

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hiroshi Wakabayashi.

Ethics declarations

Conflict of Interest

The authors declare that they have no conflict of interest.

Ethical Approval

All applicable international, national, and/or institutional guidelines for the care and use of animals were followed.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wakabayashi, H., Taki, J., Inaki, A. et al. Quantification of Myocardial Perfusion Defect Size in Rats: Comparison between Quantitative Perfusion SPECT and Autoradiography. Mol Imaging Biol 20, 544–550 (2018). https://doi.org/10.1007/s11307-018-1159-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11307-018-1159-1

Key words

Navigation