Skip to main content
Log in

Simultaneous Preconcentration of Cd(II) and Pb(II) with N,N′-bis(4-methoxysalicylidene) Ethylenediamine Coated Silica Gel Prior to Determination by Flame Atomic Absorption Spectrometry

  • Published:
Water, Air, & Soil Pollution Aims and scope Submit manuscript

Abstract

In this paper, a silica gel-based new sorbent was prepared with a Schiff base, called as N,N′-bis(4-methoxysalicylidene) ethylenediamine (MSE). The modified silica gel (Si-MSE) was used for simultaneous separation and preconcentration of Cd(II) and Pb(II) from aqueous solutions. Determination of analyte concentrations in eluates were achieved by flame atomic absorption spectrometry (FAAS). The analytical variables including pH, flow rate, and sample volume for sorption and flow rate, eluent concentration, and eluent volume for elution, were optimized by central composite design (CCD). HNO3 was used as eluent and maximum preconcentration factor was found to be 200. Limit of detections (LODs) were found to be 49.6 ng L−1 and 1.3 μg L−1 for Cd(II) and Pb(II), respectively. Validation of the developed method was performed by using certified reference material (TMDA-53.3) and mixed metal standard. The methodology was applied for determination of Cd(II) and Pb(II) in natural water samples and satisfactory results were obtained.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  • Ahmed, S. A. (2008). Alumina physically loaded by thiosemicarbazide for selective preconcentration of mercury(II) ion from natural water samples. Journal of Hazardous Materials, 156, 521–529.

    Article  CAS  Google Scholar 

  • Baran, E. K., & Yaşar, S. B. (2010). Copper and iron determination with [N, N′-Bis(salicylidene)-2,2′-dimethyl-1,3-propanediaminato] in edible oils without digestion. Journal of the American Oil Chemists’ Society, 87, 1389–1395.

    Article  CAS  Google Scholar 

  • Bartyzel, A., & Cukrowska, E. M. (2011). Solid phase extraction method for the separation and determination of chromium(III) in the presence of chromium(VI) using silica gel modified by N,N′-bis-(α-methylsalicylidene)-2,2-dimethyl-1,3-propanediimine. Analytica Chimica Acta, 707, 204–209.

    Article  CAS  Google Scholar 

  • Eklund, G., Linden, A., Tallkvist, J., & Oskarsson, A. (2003). Bioavailability of cadmium from in vitro digested infant food studied in caco-2 cells. Journal of Agricultural Food Chemistry, 51(14), 4168–4174.

    Article  CAS  Google Scholar 

  • Ferreira, S. L. C., Queiroz, A. S., Fernandes, M. S., & Santos, H. C. (2002). Application of factorial designs and Doehlert matrix in optimization of experimental variables associated with the preconcentration and determination of vanadium and copper in seawater by inductively coupled plasma optical emission spectrometry. Spectrochimica Acta B: Atomic Spectroscopy, 57, 1939–1950.

    Article  Google Scholar 

  • Ferreira, S. L. C., Santos, W. N. L., Bezerra, M. A., Lemos, V. A., & Bosque-Sendra, J. M. (2003). Use of factorial design and Doehlert matrix for multivariate optimisation of an on-line preconcentration system for lead determination by flame atomic absorption spectrometry. Analytical and Bioanalytical Chemistry, 375(3), 443–449.

    CAS  Google Scholar 

  • Guo, Y., Din, B., Liu, Y., Chang, X., Meng, S., & Tian, M. (2004). Preconcentration of trace metals with 2-(methylthio)aniline-functionalized XAD-2 and their determination by flame atomic absorption spectrometry. Analytica Chimica Acta, 504(2), 319–324.

    Article  CAS  Google Scholar 

  • Komjarova, I., & Blust, R. (2006). Comparison of liquid-liquid extraction, solid-phase extraction and co-precipitation preconcentration methods for the determination of cadmium, copper, nickel, lead and zinc in seawater. Analytica Chimica Acta, 576(2), 221–228.

    Article  CAS  Google Scholar 

  • Lara, R. F., Wuilloud, R. G., Salonia, J. A., Olsina, R. A., & Martinez, L. D. (2001). Determination of low cadmium concentrations in wine by on-line preconcentration in a knotted reactor coupled to an inductively coupled plasma optical emission spectrometer with ultrasonic nebulization. Fresenius’ Journal of Analytical Chemistry, 371(7), 989–993.

    Article  CAS  Google Scholar 

  • Lemos, V. A., Novaes, C. G., & Bezerra, M. A. (2009). An automated preconcentration system for the determination of manganese in food samples. Journal of Food Composition and Analysis, 22(4), 337–342.

    Article  CAS  Google Scholar 

  • Li, Q., Ouyang, R., Xu, G., & Liu, G. (2005). Cadmium preconcentration from aqueous environmental samples using microcrystalline phenolphthalein modified by crystal violet. Analytical Letters, 38(12), 1987–1998.

    Article  CAS  Google Scholar 

  • Li, P., Hu, B., & Li, X. (2012). Zirconia coated stir bar sorptive extraction combined with large volume sample stacking capillary electrophoresis-indirect ultraviolet detection for the determination of chemical warfare agent degradation products in water samples. Journal of Chromatography A, 1247, 49–56.

    Article  CAS  Google Scholar 

  • Ozcelik, G., Imamoglu, M., Yildiz, S. Z., & Kara, D. (2012). Chemically modified silica Gel with N-(2-aminoethyl)-salicylaldimine for simultaneous solid phase extraction and preconcentration of Cu(II), Ni(II), Cd(II) and Zn(II) in waters. Water, Air, & Soil Pollution, 223, 5391–5399.

    Article  CAS  Google Scholar 

  • Qu, R., Wang, M., Sun, C., Zhang, Y., Ji, C., Chen, H., Meng, Y., & Yin, P. (2008). Chemical modification of silica-gel with hydroxyl- or amino-terminated polyamine for adsorption of Au(III). Applied Surface Science, 255(5), 3361–3370.

    Article  CAS  Google Scholar 

  • Sabermahani, F., Hassani, Z., & Faramarzpoor, M. (2013). The use of silica gel modified with allyl 6-methyl-4-phenyl-2-thioxo-1,2,3,4-tetrahydropyrimidine-5-carboxylate for selective separation and preconcentration of lead in environmental samples. Environmental Monitoring Assessment, 185(6), 4969–4976.

    Article  CAS  Google Scholar 

  • Shah, F., Soylak, M., Kazi, T. G., & Afridi, H. I. (2013). Preconcentration of lead from aqueous solution with activated carbon cloth prior to analysis by flame atomic absorption spectrometry: a multivariate study. Journal of Analytical Atomic Spectrometry, 28, 601–605.

    Article  CAS  Google Scholar 

  • Shemirani, F., Mirroshandel, A. A., Niasari, M. S., & Kozani, R. R. (2004). Silica gel coated with Schiff’s base: synthesis and application as an adsorbent for cadmium, copper, zinc, and nickel determination after preconcentration by flame atomic absorption spectrometry. Journal of Analytical Chemistry, 59(3), 228–233.

    Article  CAS  Google Scholar 

  • Silva, E. L., Roldan, P. S., & Gine, M. F. (2009). Simultaneous preconcentration of copper, zinc, cadmium, and nickel in water samples by cloud point extraction using 4-(2-pyridylazo)-resorcinol and their determination by inductively coupled plasma optic emission spectrometry. Journal of Hazardous Materials, 171, 1133–1138.

    Article  CAS  Google Scholar 

  • Soylak, M., & Yilmaz, E. (2011). Ionic liquid dispersive liquid–liquid microextraction of lead as pyrrolidinedithiocarbamate chelate prior to its flame atomic absorption spectrometric determination. Desalination, 275, 297–301.

    Article  CAS  Google Scholar 

  • Tian, Y., Ming Xie, Z., Li Chen, M., & Wang, J. (2011). Cadmium preconcentration with bean-coat as a green adsorbent with detection by electrothermal atomic absorption spectrometry. Journal of Analytical Atomic Spectrometry, 26, 1408–1413.

    Article  CAS  Google Scholar 

  • Yebra, M. C., Salgado, J., Puig, L., & Moreno-Cid, A. (2002). Field preconcentration of cadmium from seawater by using a minicolumn packed with Amberlite XAD-4/4-(2-pyridylazo) resorcinol and its flow-injection-flame atomic absorption spectrometric determination at the ng L(−1) Level. Analytical and Bioanalytical Chemistry, 374(3), 530–534.

    Article  CAS  Google Scholar 

  • Yu, Q., Yang, J., Lin, B., & Feng, Y. (2006). Preparation of pyrenebutyric acid-modified magnesia–zirconia stationary phases using phosphonate as spacers and their application to the separation of fullerenes. Analytica Chimica Acta, 559(1), 79–88.

    Article  CAS  Google Scholar 

  • Yuan-Zhen, P., Yong-Ming, H., Dong-Xing, Y., Yan, L., & Zhen-Bin, G. (2012). Rapid analysis of heavy metals in coastal seawater using preconcentration with precipitation/co-precipitation on membrane and detection with x-ray fluorescence. Chinese Journal of Analytical Chemistry, 40(6), 877–882.

    Article  Google Scholar 

  • Zarei, Z., & Shemirani, F. (2012). Determination of nickel in food samples by flame atomic absorption spectroscopy after preconcentration and microextraction-based ionic liquids using full factorial and central composite design. Journal of Food Science, 77, 1242–1248.

    Article  Google Scholar 

Download references

Acknowledgments

The authors would like to thank the Scientific and Technological Research Council of Turkey (TUBITAK-TBAG project number 105 T153) and Balıkesir University (BAP project number 2012/40) for financial support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sema Bağdat.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tokay, F., Bağdat, S. Simultaneous Preconcentration of Cd(II) and Pb(II) with N,N′-bis(4-methoxysalicylidene) Ethylenediamine Coated Silica Gel Prior to Determination by Flame Atomic Absorption Spectrometry. Water Air Soil Pollut 226, 48 (2015). https://doi.org/10.1007/s11270-015-2352-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s11270-015-2352-3

Keywords

Navigation