Abstract
In this paper, we explore the possibility of using transition edge sensor (TES) detectors in multi-mode configuration in the focal plane of the Short Wavelength Instrument for the Polarization Explorer (SWIPE) of the balloon-borne polarimeter Large-Scale Polarization Explorer (LSPE) for the Cosmic Microwave Background (CMB) polarization. This study is motivated by the fact that maximizing the sensitivity of TES bolometers, under the augmented background due to the multi-mode design, requires a non-trivial choice of detector parameters. We evaluate the best parameter combination taking into account scanning strategy, noise constraints, saturation power, and operating temperature of the cryostat during the flight.
Similar content being viewed by others
References
L. Lamagna et al., in Proceedings of the 36th Antenna Workshop on Antennas and RF Systems for Space Science 6–9 Oct 2015, (ESTEC, Noordwijk, 2015) (in press)
The LSPE Collaboration, ArXiv e-prints (2012). http://adsabs.harvard.edu/abs/2012arXiv1208.0281T
P. de Bernardis et al., Society of Photo-Optical Instrumentation Engineers (SPIE) Conference Series 8452 (2012). doi:10.1117/12.926569
Lamagna et al., in International Conference on Electromagnetics in Advanced Applications (ICEAA), pp. 1201–1204 (2013). doi:10.1109/ICEAA.2013.6632435
M. Biasotti et al., Society of Photo-Optical Instrumentation Engineers (SPIE) Conference Series 9153, (2014). doi:10.1117/12.2057071
S. Hanany et al., astro-ph/9801291 299, 653–660 (1998). doi:10.1046/j.1365-8711.1998.01705.x
M. Biasotti et al., J. Low Temp. Phys. (Special Issue). doi:10.1007/s10909-015-1390-y
K.D. Irwin et al., J. Appl. Phys. 8, 3978–3985 (1998). doi:10.1063/1.367153
M. Dobbs et al., Rev. Sci. Instrum. 83, 7 (2012). doi:10.1063/1.4737629
J.M. Lamarre, Appl. Opt. 25, 870–876 (1986). doi:10.1364/AO.25.000870
K. D. Irwin et al., Cryogenic Particle Detection, vol. 63 (2005). doi: 10.1007/10933596_3
W. B. Tiest et al., in Proceedings of the 10th International Workshop on Low Temperature Detectors, 520, 1–3, 329-332, (2004)