Abstract
Tomography diagnostics represent an essential tool in tokamaks to infer the local plasma properties using line-integrated measurements from one or several cameras. In particular, soft X-rays (SXR) in the energy range 0.1–20 keV can provide valuable information on magnetohydrodynamic activity, magnetic equilibrium or impurity transport. Heavy impurities like tungsten (W) are a major source of concern due to significant radiation losses in the plasma core, thus they have to be kept under acceptable concentrations. Therefore, 2D SXR tomography diagnostics become crucial to estimate the W concentration profile in the plasma, quantify the W poloidal distribution and identify relevant impurity mitigation strategies. In this context, a synthetic diagnostic becomes a very valuable tool (1) to study the tomographic reconstruction capabilities, (2) to validate diagnostic design as well as (3) to assess the error propagation during the reconstruction process and impurity transport analysis. The goal of this contribution is to give some highlights on recent studies related to each of these three steps, for the development of SXR synthetic diagnostic tools in tokamak plasmas.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
In the context of an increasing world energy production based on limited fossil fuel reserves and with a doubling time of 30–40 years in the last century, e.g. from 6000 million tons of oil equivalent (Mtoe) in 1973 to more than 13,000 Mtoe in 2013 [1], controlled thermonuclear fusion could be the ideal candidate to fulfil the future energy demand. Although magnetic confinement fusion based on tokamak is currently the most advanced option, many technological and physics challenges are still on the way to be solved before reaching the technological state of a commercial fusion reactor. In particular, dust and impurities originating from wall erosion can pollute the plasma core and decrease its stability and energy confinement by radiation [2, 3]. Besides, modern tokamaks like the International Thermonuclear Experimental Reactor (ITER) will not be able to use traditional carbon as a plasma-facing material due to its high tritium retention. Tungsten was retained instead for its low tritium retention associated with good mechanical properties, its resilience to intense heat fluxes and its low erosion rate [4]. Unfortunately, non-fully ionized impurities such as tungsten can represent a major threat for the tokamak performances because of intense radiation—especially due to line emission in the soft X-ray (SXR) range 0.1–20 keV [2]. Low concentrations of tungsten impurities in the order of 10–4 in the plasma core are sufficient to compromise the plasma performance of ITER and its goal of \(Q = P_{fusion} /P_{heating} \ge 10\) [5]. This implies that the development of X-ray diagnostic tools becomes crucial to monitor the local density of impurities in the plasma, to study their transport and to identify actuators that can prevent or mitigate their central accumulation [6, 7]. However, the correct estimation of the local impurity concentration relies on the proper characterization of the detector spectral response as well as the detailed emissivity features of the plasma, namely the filtered impurity cooling factor [5]. In this context, a synthetic diagnostic becomes a very valuable tool to study the tomographic reconstruction capabilities, to validate diagnostic design as well as to assess the error propagation during the reconstruction process [8]. Therefore, a complete synthetic diagnostic tool should consider the following steps:
-
Detector signal and/or spectrum reconstruction from a given geometry and plasma scenario,
-
Tomographic inversion to estimate the local emissivity from the synthetic measurements,
-
Impurity density reconstruction and subsequent transport analysis.
The goal of this contribution is to give some highlights on recent studies related to each of these three steps, for the development of SXR synthetic diagnostic tools in tokamak plasmas. In the second section, the potential of artificial neural network for fast tomographic inversions is briefly discussed. In the third section, a synthetic diagnostic is employed in order to predict the observed SXR spectrum in different tokamak scenarios. In the fourth section, the influence of perturbative noise on the reconstruction of impurity transport coefficients is investigated. Finally, some conclusions and perspectives are given in the last section.
Soft X-ray Tomography and the Potential of Neural Networks for Fast Inversions
As introduced in the previous section, reliable SXR diagnostic tools are essential to monitor the local impurity density, study W transport in the plasma core and identify actuators to avoid W central accumulation. Furthermore, the impurity density can exhibit poloidal asymmetries, for instance in the case of plasma rotation (induced by a neutral beam of fast particles) [9] or by the local modification of the electrostatic potential (e.g. during ion cyclotron resonance heating) [10]. It has been shown that these asymmetries can significantly impact the radial impurity transport [7]. Therefore, 2D tomography diagnostics become crucial to estimate the tungsten concentration profile in the plasma, quantify the 2D poloidal distribution and identify relevant impurity mitigation strategies [11].
Hereafter, the geometry of the SXR diagnostic of Tore Supra [12], consisting of two detector-pinhole cameras as depicted in Fig. 1, is considered. In the Line-of-Sight (LoS) approximation, the measurements \(f_{i}\) of the i-th detector (in W m−2) looking at the plasma is given by the line integral:
where \(\varphi_{i}\) is the impinging power on the detector (in W), \(E_{i}\) denotes the geometrical etendue (in m−2) of the detector-aperture system, \(\varepsilon^{\eta } \left( {x,y} \right)\) is the 2D emissivity field (in W m−3) filtered by the spectral response \(\eta \left( {hv} \right)\) of the detector and \(\tilde{f}_{i}\) the perturbative noise in the i-th channel. For tomographic purposes, the forward problem can be discretized as follows:
where \(\varepsilon_{j}\) is the plasma emissivity in the j-th pixel and the transfer matrix elements \(T_{ij}\) correspond to the response function of the detection system. Unfortunately, reconstructing the local SXR emissivity consists in an ill-posed inverse problem by nature, with in addition a sparse measurements set \(\left\{ {{\text{f}}_{{\text{i}}} } \right\}_{{{\text{i}} = 1..{\text{N}}}}\) due to the lack of available space in tokamaks. An adequate regularization procedure is thus required to perform the reconstruction.
The most common method relies on the Tikhonov regularization [13]. In this case, some a priori information is added in the reconstruction process through a regularization matrix \(H\) that imposes smoothness on the emissivity profiles, for instance by minimizing the Fisher information. It is then possible to extract a meaningful solution by finding the minimum of a functional:
where the regularization parameter \(\lambda\) acts as a balance between \(\chi^{2} = \left| {{\varvec{f}} - {\varvec{T}}.{\varvec{\varepsilon}}} \right|^{2}\) minimization and smoothness of the solution. The value of \(\lambda\) can be optimized based on several different methods [14]. Inversion methods alternative to the Tikhonov regularization can be found in the literature, e.g. based on Bayesian inference [15], a Monte-Carlo approach [16] or on a genetic algorithm [17]. However, most of these methods still require a significant computational time although significant effort is being performed towards real-time applications [18]. In this context, deep learning and artificial neural networks [19] represent the ideal candidate in the perspective of real-time impurity control. Neural networks are able to fit any multidimensional function in a given input range—with the adequate network complexity and training process—by adjusting properly the weights and biases of the neurons [20]. Besides tomography [19] and image recognition [21], they have been used in support of simulation with high computational cost, e.g. turbulent transport modelling [22], and to make empirical correlations from large experimental databases, e.g. disruption prediction [23].
A neural network with two fully connected layers of 30 sigmoid neurons has been recently developed in the Tore Supra geometry to achieve fast SXR inversions, as depicted in Fig. 1, and trained with a large database of synthetic profiles [24]. The input layer is composed of 69 neurons, corresponding to the number of SXR channels used for the inversion and of an output layer of 2500 neurons to produce 50 × 50 pixels tomograms. The training loss that assesses the network performances is defined by the mean square error cost function:
where \(\left( {{\text{w}},{\text{b}}} \right)\) denotes the weights and biases of each neuron, \(\left( {{\text{x}},{\text{y}}\left( {\text{x}} \right)} \right)\) represent a training sample, i.e. measurements x and tomogram \({\text{y}}\left( {\text{x}} \right)\), with \({\text{a}}\left( {{\text{x}},{\text{w}},{\text{b}}} \right)\) the corresponding output of the network. A stochastic gradient-descent method [25] is used to iteratively updates the weights and biases in the direction of the negative gradient of the cost function, computed using a backpropagation algorithm [26]. The evolution of the training loss over the training process is shown in Fig. 2, where 90% of the data were used for training and 10% were kept outside of the training set for validation purposes.
Here, we test this neural network with synthetic emissivity patterns from the validation set, exhibiting poloidal asymmetries as presented in Fig. 3 and with 2% of Gaussian noise in the measurements to assess the neural network robustness. It can be seen that the network is able to properly recover the synthetic emissivity patterns. However, the emissivity error can locally peak from 15% to up to 40% as shown in Fig. 3g–i), which could be detrimental for the SXR analysis of impurities. The reconstruction error could be further reduced by optimizing the network parameters (number of hidden layers and neurons per layer) and the training process, e.g. using the dropout method. The relatively high level of error observed on Fig. 3 is the drawback of the simplicity of fully connected layers as compared with deeper de-convolutional networks, for which the structure is specifically adapted for image recognition and tomography tasks [19, 27].
The main advantage of the neural network approach is that, once properly train with a synthetic or experimental database, the neural network can perform inversions in a time < 0.1 ms, two orders of magnitude faster than Tikhonov regularization and compatible with real-time control. Two options can be considered while applying a neural network to experimental data. The first option is to directly train the neural network on a database of experimental tomograms already obtained from another method, typically using Tikhonov regularization, like in [19]. This option allows performing reconstructions much faster with respect to the traditional regularization, at the cost of an additional error induced by the neural network, but requires the prior existence of a reliable and complete experimental database. The second option is to train the neural network on a synthetic database in a first step, and in a second step to apply it on experimental data. The advantage of such an approach is to be able to perform the tomographic task ab initio, for instance from the beginning of tokamak operations. However, the reliability of the latter approach depends largely on the capabilities of the synthetic diagnostics to describe accurately the reality of the experiments.
GEM Synthetic Diagnostic for Impurity Transport Studies on the WEST Tokamak
The Tore Supra tokamak was recently upgraded into WEST—for Tungsten (W) Environment in Steady-State Tokamak, to serve as a test-bed for ITER divertor components in long pulse operation [28]. It was also the opportunity to develop a new SXR detection system based on the Gas Electron Multiplier (GEM) technology [29, 30], after laboratory tests of a GEM prototype at CELIA [31] and on ASDEX-Upgrade [32]. Indeed, the semiconductor diodes traditionally used in tokamaks will not whistand the harsh ITER environment in the D-T operations and more robust technologies based for instance on a gaseous detection volume have to be considered [33]. A specificity of the GEM WEST detectors is that they will operate in photon-counting mode, allowing to classify incident photons in energy bands and thus recovering some spectral information on the SXR radiation [34]. This will open new possibilities to disentangle the different SXR contribution from W emissivity, i.e. line emission, radiative recombination and Bremsstrahlung radiation.
In this context, a synthetic diagnostic has been developed in order to investigate the reconstruction capabilities of the GEM WEST cameras [8]. The diagnostic is composed of two cameras placed in the same poloidal cross-section, as shown in Fig. 4. The synthetic diagnostic includes the SXR source from a given plasma scenario, the photoionization probability, electron cloud transport in the detection volume using the Magboltz code [35], and tomographic reconstruction of the radiation from the GEM signal in the WEST geometry [36]. In this section, we show a set of three simulations of the acquired SXR spectrum by the GEM cameras in the case of a standard WEST Physics basis scenario with heating power of 12 MW, Ip = 0.6 MA including W impurities [37]. The SXR emissivity is modelled as follows:
with \(n_{e}^{ }\), \(T_{e}\) the electron density and temperature and where \(L_{H}\) and \(L_{W}\) denote the Hydrogen and W cooling factors, respectively. The W spectral properties, as well as recombination and ionization coefficients of W ions are obtained from the open ADAS database [38]. The scenario includes the possibility to choose the diffusion and convective W transport coefficients (D,V) to modify the W ionization equilibrium.
The Fig. 5a reports the synthetic GEM spectrum obtained for the three scenarios considered: (1) pure plasma hydrogen plasma, i.e. a tungsten concentration \(c_{W} = 0\), (2) \(c_{W} = 10^{ - 4}\) with an intermediate transport case (D,V)x1 and (3) \(c_{W} = 10^{ - 4}\) with a strong transport case (D,V)x10, i.e. where the transport coefficients have been increased by one order of magnitude to highlight the transport effects. The transport coefficients values in the (D,V)x1 scenario correspond to D = 0.5 m2 s−1, V = − 1 m s−1 in the plasma core \(r/a < 0.6\) and D = 2 m2 s−1, V = − 5 m s−1 at the plasma edge. A significant increase of the SXR radiation is observed around 2 keV. This is expected since W line emission is dominant in this spectral region for the considered plasma core temperature Te ≈ 3–4 keV, while the Bremsstrahlung radiation becomes dominant for photon energies above 4 keV. The impact of transport intensity on the W SXR cooling factor LW can be seen on Fig. 5b. In particular, the enhanced transport reduces the W radiation in the plasma core, since high W ionization states are more easily transported from the core to the edge, decreasing the mean W effective charge in the core.
Reconstruction of Impurity Transport Coefficients and Impact of Perturbative Noise
In this section, we investigate the possibility of reconstructing the impurity transport coefficients (D,V) from given measurements of the local impurity density \(n_{S}\) in the presence of different levels of perturbative noise. The impurity density is generally estimated by reformulating Eq. (5):
given that the species S (e.g. W) is the dominant impurity contributing to the emissivity. This can be performed experimentally by SXR tomography as seen in the previous sections, coupled with other diagnostics like Visible–UV spectroscopy to cover a wider radial range. However, in this section, the details of the detector response, impurity spectral features and tomographic reconstruction are not included in the analysis and the error in the impurity density reconstruction is rather described by a statistical noise with a Gaussian distribution and without systematic errors, for simplicity purposes. The issue of systematic errors in the geometry or camera calibration is thus let for further investigations. The (D,V) reconstruction relies on the Gradient-Flux (G-F) method [39, 40], which is applicable when the impurity density profile is evolving in time while the plasma conditions remain stable. Indeed, in this case the radial flux of impurities can be expressed as:
where the radial flux and gradient of impurity are time dependent while the diffusive and convective coefficients remain constant. The conditions can be fulfilled during the recovery phase of a sawtooth (ST) crash or just after a controlled impurity injection at a trace level. The method allows extracting experimentally the transport coefficient thanks to a linear fit:
where \(- D\left( r \right)\) is the slope and \(V\left( r \right)\) is the offset. The impurity flux can be reconstructed from:
The G-F linear fit in Eq. (8) is subject to experimental uncertainties, in particular in the plasma region where the impurity density gradient is low (i.e. flat radial profile). It is thus valuable to develop a synthetic diagnostic tool to assess the reconstruction capabilities for different levels of noise in the reconstructed impurity density.
Hereafter, we will consider an ideal tokamak in circular geometry with a major radius of R = 2.5 m and a minor radius of a = 0.5 m. The assumed (D,V) coefficients are shown in Fig. 6a, together with the steady-state impurity density profile obtained using Eq. (8) when \(\Gamma_{S} \left( {r,t} \right) = 0\):
Equation (10) leads to the following impurity density profile:
The simulation is simply performed by solving numerically the continuity equation for the impurities:
The obtained impurity 2D map is presented in Fig. 7a. The time evolution of the impurity density for a few radial locations is also displayed in Fig. 7b. ST crashes are simply implemented by transiently increasing the diffusive coefficient up to D = 30 m2 s−1 in the region \(r/a < 0.3\), as presented in Fig. 8a. An impurity injection is also added by putting a non-zero source term \(S_{ext} > 0\) at t = 0.11 s at the plasma edge, i.e. for \(r/a > 0.95\).
An attempt of reconstructing the transport coefficients in the ST recovery phase, excluding the impurity injection phase i.e. for the time window \(t = \left[ {0.033s;0.099s} \right]\), is shown in Fig. 8 for 0.1%, 0.5% and 2% of perturbative noise. The impurity density is assumed to be reconstructed over the full radial range including a statistical error with a Gaussian distribution varying from 0.1 to 10%. The impurity flux is estimated using the obtained noisy density in Eq. (10) and the reconstructed coefficients (\(D_{rec}\), \(V_{rec}\)) are estimated from the G-F linear fit described by Eq. (9). The error bars in the linear fit correspond to \(\pm 2{\upsigma }\), i.e. 95% of values around the mean for a normal distribution. As a result, it is observed that the reconstruction is only reliable inside the ST inversion radius \(r/a < 0.3\). This is expected since it is the region of significant time evolution of the impurity flux during the ST recovery phase. While the reconstruction is still robust for 0.5% of perturbative noise and \(r/a < 0.3\), see Fig. 8c, a Gaussian noise of \( \gtrsim 2\%\) is enough to significantly perturb the reconstruction over the full radial range, as shown on Fig. 8d.
Finally, the GF reconstruction method is applied just after the impurity injection, where the time window used for the reconstruction is indicated by the red dash lines on Fig. 7a. The reconstruction results are presented in Fig. 9a–c) for different levels of Gaussian noise—0.1%, 2% and 10%—together with the linear fit of Eq. (8) in Fig. 9d–f. Overall, it can be seen that the transport coefficient profiles are recovered over the full radial range with a better robustness against statistical noise than during the ST recovery phase alone. Indeed, a strong noise of 10% is necessary to significantly perturb the (\(D_{rec}\), \(V_{rec}\)) profiles. However, it is observed that the reconstruction is less reliable in the limit regions \(r/a < 0.1\) and \(r/a > 0.8\) where the coefficients can be underestimated (in absolute value), even for 0.1% and 2% of Gaussian noise, as shown in Fig. 9a, b. This can be interpreted by the fact that both the radial gradient and flux of impurities are lower in these regions, decreasing the quality of the G-F linear fit. As a conclusion, the reconstructions during the ST recovery phase and during the impurity injection phase showed that the G-F method is mostly robust in the regions with a significant radial impurity gradient and for strong time evolution of the impurity profile.
Conclusion
In this paper, some recent studies related to the development of X-ray synthetic diagnostic tools have been presented, in the prospect of impurity transport monitoring. First, the potential of neural networks to perform tomographic inversions with real-time capabilities was demonstrated based on a synthetic database in the geometry of the Tore Supra SXR diagnostic. A good capability of the network to learn and reproduced the emissivity patterns was found with 2% of Gaussian noise in the measurements, although the local reconstruction error can peak from 15% to up to 40%. Secondly, a GEM synthetic diagnostic was applied in a WEST scenario to illustrate the influence of plasma parameters, in particular the tungsten concentration level and transport effects, on the acquired spectrum and the possibility to disentangle the different contributions to the SXR spectrum. Finally, the robustness of the reconstruction of the impurity transport coefficients (D,V) against 0.1–10% of perturbative Gaussian noise was investigated with a using the G-F method, during a ST recovery phase and during an impurity injection phase. The study allowed to reveal the plasma regions in which the (D,V) reconstruction is the most sensitive to experimental uncertainties. More specifically, the (D,V) reconstruction is no more valid outside of the ST inversion radius, here for \(r/a > 0.3\), during the ST recovery phase. In the impurity injection phase, the reconstruction is valid over the full profile up to 10% of noise, although less reliable in the limit regions \(r/a < 0.1\) and \(r/a < 0.8\) of lower gradients and flux of impurities for the studied scenario.
References
International Energy Agency, Key World Energy Statistics (OECD/IEA, Paris, 2015)
T. Putterich, R. Neu, R. Dux, A.D. Whiteford, M.G. O’Mullane, Modelling of measured tungsten spectra from ASDEX upgrade and predictions for ITER. Plasma Phys. Control. Fusion 50(8), 085016 (2008)
R.D. Smirnov, S.I. Krasheninnikov, A.Yu. Pigarov, T.D. Rognlien, Tungsten dust impact on ITER-like plasma edge. Phys. Plasmas 22(1), 012506 (2015)
R.A. Pitts, S. Carpentier, F. Escourbiac, T. Hirai, V. Komarov, S. Lisgo, A.S. Kukushkin, A. Loarte, M. Merola, A. Sashala Naik, R. Mitteau, M. Sugihara, B. Bazylev, P.C. Stangeby, A full tungsten divertor for ITER: physics issues and design status. J. Nucl. Mater. 438, S48–S56 (2013)
T. Putterich, R. Neu, R. Dux, A.D. Whiteford, M.G. O’Mullane, H.P. Summers, the ASDEX Upgrade Team, Calculation and experimental test of the cooling factor of tungsten. Nucl. Fusion 50(2), 025012 (2010)
F.J. Casson, C. Angioni, E.A. Belli, R. Bilato, P. Mantica, T. Odstrcil, T. Pütterich, M. Valisa, L. Garzotti, C. Giroud, J. Hobirk, C.F. Maggi, J. Mlynar, M.L. Reinke, JET EFDA Contributors, and ASDEX-Upgrade Team, Theoretical description of heavy impurity transport and its application to the modelling of tungsten in JET and ASDEX upgrade. Plasma Phys. Control. Fusion 57, 014031 (2015)
C. Angioni, F.J. Casson, P. Mantica, T. Pütterich, M. Valisa, E.A. Belli, R. Bilato, C. Giroud, P. Helander, The impact of poloidal asymmetries on tungsten transport in the core of JET H-mode plasmas. Phys. Plasmas 22(5), 055902 (2015)
A. Jardin, D. Mazon, P. Malard, M. O'Mullane, M. Chernyshova, T. Czarski, K. Malinowski, G. Kasprowicz, A. Wojenski, K. Pozniak, On a gas electron multiplier based synthetic diagnostic for soft x-ray tomography on WEST with focus on impurity transport studies. JINST 12, C08013 (2017)
J.A. Wesson, Poloidal distribution of impurities in a rotating tokamak plasma. Nucl. Fusion 37(5), 577 (1997)
M.L. Reinke, I.H. Hutchinson, J.E. Rice, N.T. Howard, A. Bader, S. Wukitch, Y. Lin, D.C. Pace, A. Hubbard, J.W. Hughes, Y. Podpaly, Poloidal variation of high-Z impurity density due to hydrogen minority ion cyclotron resonance heating on Alcator C-Mod. Plasma Phys. Control. Fusion 54(4), 045004 (2012)
T. Odstrcil, T. Pütterich, C. Angioni, R. Bilato, A. Gude, M. Odstrcil, ASDEX Upgrade Team, and the EUROfusion MST1 Team, The physics of W transport illuminated by recent progress in W density diagnostics at ASDEX Upgrade. Plasma Phys. Control. Fusion 60, 14003 (2018)
D. Mazon, D. Vezinet, D. Pacella, D. Moreau, L. Gabelieri, A. Romano, P. Malard, J. Mlynar, R. Masset, P. Lotte, Soft x-ray tomography for real-time applications: present status at Tore Supra and possible future developments. Rev. Sci. Instrum. 83, 063505 (2012)
M. Anton, H. Weisen, M.J. Dutch, W. von der Linden, F. Buhlmann, R. Chavan, B. Marletaz, P. Marmillod, P. Paris, X-ray tomography on the TCV tokamak. Plasma Phys. Control. Fusion 38, 1849–1878 (1996)
A. Jardin, D. Mazon, J. Bielecki, Comparison of two regularization methods for SXR tomography at Tore Supra. Phys. Scr. 91, 044007 (2016)
T. Wang, D. Mazon, J. Svensson, A. Liu, C. Zhou, L. Xu, L. Hu, Y. Duan, G. Verdoolaege, Bayesian data analysis for Gaussian process tomography. J. Fusion Energ. 38, 445–457 (2019)
J. Bielecki, Metropolis-hastings Monte Carlo method for neutron emissivity tomographic inversion in tokamak plasma. J. Fusion Energ. 37, 201–210 (2018)
J. Bielecki, A genetic algorithm-based method of neutron emissivity tomographic inversion for tokamak plasma. Fusion Eng. Des. 127, 160–167 (2018)
V. Loffelmann, J. Mlynar, M. Imrisek, D. Mazon, A. Jardin, V. Weinzettl, M. Hron, Minimum Fisher regularization adapted to real-time tomography. Fusion Sci. Technol. 69, 505 (2016)
D.R. Ferreira, P.J. Carvalho, H. Fernandes, Full-pulse tomographic reconstruction with deep neural networks. Fusion Sci. Technol. 74, 47–56 (2018)
M.A. Nielsen, Neural Networks and Deep Learning (Determination Press, San Francisco, 2015)
R.M. Cichy, A. Khosla, D. Pantazis, A. Torralba, A. Oliva, Comparison of deep neural networks to spatio-temporal cortical dynamics of human visual object recognition reveals hierarchical correspondence. Sci. Rep. 6, 27755 (2016)
J. Citrin, S. Breton, F. Felici, F. Imbeaux, T. Aniel, J.F. Artaud, B. Baiocchi, C. Bourdelle, Y. Camenen, J. Garcia, Real-time capable first principle based modelling of tokamak turbulent transport. Nucl. Fusion 55, 092001 (2015)
B. Cannas, A. Fanni, G. Pautasso, G. Sias, the ASDEX Upgrade Team, Disruption prediction with adaptive neural networks for ASDEX upgrade. Fusion Eng. Des. 86, 1039–1044 (2011)
A. Jardin, J. Bielecki, D. Mazon, J. Dankowski, K. Król, Y. Peysson, M. Scholz, Neural networks: from image recognition to tokamak plasma tomography. Laser Part. Beams 37, 171–175 (2019)
D. Rumelhart, G. Hinton, R. Williams, Learning representations by back-propagating errors. Nature 323, 533–536 (1986)
Y. Lecun, L. Bottou, Y. Bengio, P. Haffner, Gradient-based learning applied to document recognition. Proc. IEEE 86, 2278–2324 (1998)
R. Cichy, A. Khosla, D. Pantazis, A. Torralba, A. Oliva, Comparison of deep neural networks to spatio-temporal cortical dynamicsof human visual object recognition reveals hierarchical correspondence. Sci. Rep. 6, 27755 (2016)
J. Bucalossi, M. Missirlian, P. Moreau, F. Samaille, E. Tsitrone, D. van Houtte, T. Batal, C. Bourdelle, M. Chantant, Y. Corre, X. Courtois, L. Delpech, L. Doceul, D. Douai, H. Dougnac, F. Faïsse, C. Fenzi, F. Ferlay, M. Firdaouss, L. Gargiulo, P. Garin, C. Gil, A. Grosman, D. Guilhem, J. Gunn, C. Hernandez, D. Keller, S. Larroque, F. Leroux, M. Lipa, P. Lotte, A. Martinez, O. Meyer, F. Micolon, P. Mollard, E. Nardon, R. Nouailletas, A. Pilia, M. Richou, S. Salasca, J.-M. Travère, The WEST project: testing ITER divertor high heat flux component technology in a steady state tokamak environment. Fusion Eng. Des. 89(7), 907–912 (2014)
F. Sauli, The gas electron multiplier (GEM): operating principles and applications. Nucl. Instrum. Methods A 805, 2 (2016)
D. Mazon, A. Jardin, C. Coston, F. Faisse, M. Chernyshova, T. Czarski, G. Kasprowicz, A. Wojenski, GEM detectors for WEST and potential application for heavy impurity transport studies. JINST 11, C08006 (2016)
T. Czarski, M. Chernyshova, K. Malinowski, K.T. Pozniak, G. Kasprowicz, P. Kolasinski, R. Krawczyk, A. Wojenski, P. Linczuk, W. Zabolotny, A. Jardin, D. Mazon, K. Jakubowska, G. Boutoux, F. Burgy, S. Hulin, D. Batani, Measuring issues in the GEM detector system for fusion plasma imaging. JINST 13, C08001 (2018)
M. Chernyshova, K. Malinowski, T. Czarski, A. Wojenski, D. Vezinet, K.T. Pozniak, G. Kasprowicz, D. Mazon, A. Jardin, A. Herrmann, E. Kowalska-Strzeciwilk, R. Krawczyk, P. Kolasinski, W. Zabołotny, P. Zienkiewicz, Gaseous electron multiplier-based soft x-ray plasma diagnostics development: preliminary tests at ASDEX Upgrade. Rev. Sci. Instrum. 87(11), 11E325 (2016)
L. Hu, K. Chen, Y. Chen, H. Cao, S. Li, H. Yu, J. Zhan, J. Shen, S. Qin, X. Sheng, J. Zhao, L. Niu, C. Feng, J. Ge, S. Zhang, B. Zhang, Preliminary design and R&D of ITER diagnostic-radial X-ray camera. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 870(3), 50–54 (2017)
T. Czarski, M. Chernyshova, K. Malinowski, K.T. Pozniak, G. Kasprowicz, P. Kolasinski, R. Krawczyk, A. Wojenski, W. Zabolotny, The cluster charge identification in the GEM detector for fusion plasma imaging by soft Xray diagnostics. Rev. Sci. Instrum. 87(11), 11E336 (2016)
S.F. Biagi, Monte Carlo simulation of electron drift and diffusion in counting gases under the influence of electric and magnetic fields. Nucl. Instrum. Methods A 421, 234 (1999)
A. Jardin, D. Mazon, M. O'Mullane, J. Mlynar, V. Loffelmann, M. Imrisek, M. Chernyshova, T. Czarski, G. Kasprowicz, A. Wojenski, C. Bourdelle, P. Malar, Tomographic capabilities of the new GEM based SXR diagnostic of WEST. JINST 11, C07006 (2016)
C. Bourdelle, J.F. Artaud, V. Basiuk, M. Bécoulet, S. Brémond, J. Bucalossi, H. Bufferand, G. Ciraolo, L. Colas, Y. Corre, X. Courtois, J. Decker, L. Delpech, P. Devynck, G. Dif-Pradalier, R.P. Doerner, D. Douai, R. Dumont, A. Ekedahl, N. Fedorczak, C. Fenzi, M. Firdaouss, J. Garcia, P. Ghendrih, C. Gil, G. Giruzzi, M. Goniche, C. Grisolia, A. Grosman, D. Guilhem, R. Guirlet, J. Gunn, P. Hennequin, J. Hillairet, T. Hoang, F. Imbeaux, I. Ivanova-Stanik, E. Joffrin, A. Kallenbach, J. Linke, T. Loarer, P. Lotte, P. Maget, Y. Marandet, M.L. Mayoral, O. Meyer, M. Missirlian, P. Mollard, P. Monier-Garbet, P. Moreau, E. Nardon, B. Pégourié, Y. Peysson, R. Sabot, F. Saint-Laurent, M. Schneider, J.M. Travère, E. Tsitrone, S. Vartanian, L. Vermare, M. Yoshida, R. Zagorski, JET Contributors, WEST physics basis. Nucl. Fusion 55, 063017 (2015)
The Open ADAS Project (Atomic Data and Analysis Structure). https://open.adas.ac.uk
G. Bonheure, J. Mlynar, A. Murari, C. Giroud, P. Belo, L. Bertalot, S. Popovichev, JET-EFDA Contributors, A novel method for trace tritium transport studies. Nucl. Fusion 49, 085025 (2009)
M. Sertoli, C. Angioni, T. Odstrcil, ASDEX Upgrade Team, and EUROFusion MST1 Team, Parametric dependencies of the experimental tungsten transport coefficients in ICRH and ECRH assisted ASDEX Upgrade H-modes. Phys. Plasmas 24, 112503 (2017)
Acknowledgements
This work has received financial support from the POLONIUM collaboration program between the French ministries MEAE, MESRI and the Ministry of Science and Higher Education of Poland.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Jardin, A., Bielecki, J., Mazon, D. et al. Synthetic X-ray Tomography Diagnostics for Tokamak Plasmas. J Fusion Energ 39, 240–250 (2020). https://doi.org/10.1007/s10894-020-00250-9
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10894-020-00250-9