In order to investigate the role of thermo-oxidative aging on the crystal structure of crosslinked polyethylene (XLPE) at temperatures below and above the melting point, thermo-oxidative aging was conducted on XLPE cable insulation at 100, 120, 140 and 160 °C respectively. The crystal structure of the fresh sample and aged samples was characterized by X-ray diffraction, differential scanning calorimetry (DSC) and scanning electron microscopy tests. The concentration of antioxidants in XLPE samples was measured by the DSC method. It was deduced by the obtained results that the thermo-oxidative aging process could be divided into the physical aging stage and the chemical aging stage depending on the concentration of antioxidants in XLPE. In the physical aging stage, re-crystallization process led to the improvement of crystal structure and the increase in crystallinity. In the chemical aging stage, the breakage of intramolecular and intermolecular bonds led to drastic chains scission, resulting in the decrease in crystallinity. At 100 °C, the thermo-oxidative aging mainly affected the amorphous regions and had a limited effect on the crystalline regions. At 120, 140 and 160 °C, the thermo-oxidative aging affected the molten spherulites, resulting in decreased lamellae, increased lamellar spacing and the destruction of spherulites.
Similar content being viewed by others
References
V. Englund, R. Huuva, S.M. Gubanski, T. Hjertberg, Synthesis and efficiency of voltage stabilizers for XLPE cable insulation. IEEE Trans. Dielectr. Electr. Insul. 16, 1455–1461 (2009)
J.Y. Li, H. Li, F.S. Zhou, S.H. Wang, J.K. Zhao, B.H. Ouyang, Copper-catalyzed oxidation caused by copper-rich impurities in cross-linked polyethylene cable insulation. J. Mater. Sci.: Mater. Electron. 27(1), 806–810 (2016)
H. Li, J.Y. Li, W.W. Li, X.T. Zhao, G.L. Wang, M.A. Alim, Fractal analysis of side channels for breakdown structures in XLPE cable insulation. J. Mater. Sci.: Mater. Electron. 24(5), 1640–1643 (2013)
J.Y. Li, F.S. Zhou, M.D. Min, S.T. Li, R. Xia, The energy distribution of trapped charges in polymers based on isothermal surface potential decay model. IEEE Trans. Dielectr. Electr. Insul. 22(3), 1723–1732 (2015)
J.P. Jones, J.P. Llewellyn, T.J. Lewis, The contribution of field-induced morphological change to the electrical aging and breakdown of polyethylene. IEEE Trans. Dielectr. Electr. Insul. 12(5), 951–966 (2005)
P.S. He, Structure and Properties of Polymers (Alpha Science International Ltd, Britain, 2014)
D. Andjelkovic, N. Rajakovic, Influence of accelerated aging on mechanical and structural properties of cross-linked polyethylene (XLPE) insulation. Electr. Eng. 83(1), 83–87 (2001)
S. Grzybowski, P. Zubielik, E. Kuffel, Changes of thermoplastics PE cable insulation properties caused by overload current. IEEE Trans. Power Deliv. 4(3), 1507–1512 (1989)
J. Muccigrosso, P.J. Phillips, The morphology of crosslinked polyethylene insulation. IEEE Trans. Electr. Insul. EI-13, 172–178 (1978)
J.Y. Li, X.T. Zhao, G.L. Yin, S.T. Li, The effect of accelerated water tree aging on the properties of XLPE cable insulation. IEEE Trans. Dielectr. Electr. Insul. 18(5), 1562–1569 (2011)
J.Y. Li, H. Li, Q.M. Wang, X. Zhang, B.H. Ouyang, J.K. Zhao, Accelerated inhomogeneous degradation of XLPE insulation caused by copper-rich impurities at elevated temperature. IEEE Trans. Dielectr. Electr. Insul. 23(3), 1789–1797 (2016)
M. Nedjar, Effect of thermal ageing on the electrical properties of crosslinked polyethylene. J. Appl. Polym. Sci. 111(4), 1985–1990 (2009)
M. Nedjar, A. Beroual, A. Boubakeur, Influence of thermal aging on the electrical properties of poly(vinylchloride). J. Appl. Polym. Sci. 102(5), 4728–4733 (2006)
C. Kim, Z. Jin, P. Jiang, Z. Zhu, G. Wang, Investigation of dielectric behavior of thermally aged XLPE cable in the high-frequency range. Polym. Test. 25(4), 553–561 (2006)
M. Karakelle, P.J. Phillips, The influence of structure on water treeing in crosslinked polyethylene-Accelerated aging method. IEEE Trans. Dielectr. Electr. Insul. 24(6), 1083–1092 (1989)
L. Boukezzi, A. Boubakeur, C. Laurent, M. Lallouani, Observations on structural changes under thermal ageing of cross-linked polyethylene used as power cables insulation. Iran. Polym. J. 17(8), 611–624 (2008)
A. Vatansever, P.J. Phillips, Physico-chemical analysis of a failed cable. IEEE Trans. Electr. Insul. 24(6), 1121–1132 (1990)
S. Ratner, A. Weinberg, G. Marom, Morphology and mechanical properties of crosslinked PE/PE composite materials. Polym. Comp. 24(3), 422–427 (2003)
M.S. Rabello, J.R. White, The role of physical structure and morphology in the photodegradation behavior of polypropylene. Polym. Degrad. Stab. 56(1), 55–73 (1997)
J.W. Billing, Thermal history of cable insulation revealed by DSC examination. In: International Conference on Dielectric Materials, Measurements and Applications, vol. 121(23) (1988), pp. 12112–12114
K. Kobayashi, S. Nakayama, T. Niwa, A new estimation method of thermal history in crosslinked polyethylene. In: International Conference on Properties and Applications of Dielectric Materials (ICPADM), vol. 2(3), (1994), pp. 678–681
L. Contat-Rodrigo, A.R. Greus, Biodegradation studies of LDPE filled with biodegradation additives: morphological changes. I. J. Appl. Polym. Sci. 83(8), 1683–1691 (2002)
Y. Tanaka, G. Chen, Y. Zhao, A.E. Davies, A.S. Vaughan, T. Takada, Effect of additives on morphology and space charge accumulation in low density polyethylene. IEEE Transactions on Dielectrics and Electrical Insulation 10(1), 148–154 (2003)
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Rights and permissions
About this article
Cite this article
Li, H., Li, J., Ma, Y. et al. The role of thermo-oxidative aging at different temperatures on the crystal structure of crosslinked polyethylene. J Mater Sci: Mater Electron 29, 3696–3703 (2018). https://doi.org/10.1007/s10854-017-8301-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10854-017-8301-8