Abstract
Background
Cardiac computed tomography (CT) is commonly used to study left atrial (LA) and pulmonary veins (PVs) anatomy before atrial fibrillation (AF) ablation. The aim of the study was to determine the impact of pre-procedural cardiac CT with 3D reconstruction on procedural outcomes and radiological exposure in patients who underwent radiofrequency catheter ablation (RFA) of AF.
Methods
In this registry, 493 consecutive patients (age 62 ± 8 years, 70% male) with paroxysmal (316) or persistent (177) AF who underwent first procedure of RFA were included. A pre-procedural CT scan was obtained in 324 patients (CT group). Antral pulmonary vein isolation was performed in all patients using an open-irrigation-tip catheter with a 3D electroanatomical navigation system. Procedural outcome, including radiological exposure, and clinical outcomes were compared among patients who underwent RFA with (CT group) and without (no CT group) pre-procedural cardiac CT.
Results
Acute PV isolation was obtained in all patients, with a comparable overall complication rate between CT and no CT group (4.3% vs 3%, p = 0.7). No differences were observed about mean duration of the procedure (231 ± 60 vs 233 ± 58 min, p = 0.7) and fluoroscopy time (13 ± 10 vs 13 ± 8 min, p = 0.6) among groups. Cumulative radiation dose resulted significantly higher in the CT group compared with no CT group (8.9 ± 24 vs 4.8 ± 15 mSv, P = 0.02). At 1 year, freedom from AF/atrial tachycardia were comparable among groups (CT group, 227/324 (70%), vs no CT group,119/169 (70%), p = ns).
Conclusions
Pre-procedural CT does not improve safety and efficacy of AF ablation, increasing significantly the cumulative radiological exposure.
Similar content being viewed by others
References
Kistler PM, Earley MJ, Harris S, Abrams D, Ellis S, Sporton SC, et al. Validation of three-dimensional cardiac image integration: use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 2006;17(4):341–8.
Ho SY, Sanchez-Quintana D, Cabrera JA, Anderson RH. Anatomy of the left atrium: implications for radiofrequency ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 1999;10(11):1525–33.
Heist EK, Holmvang G, Abbara S, Ruskin JN, Mansour M. Pre-Procedural Imaging to Direct Catheter Ablation of Atrial Fibrillation: Anatomy and Ablation Strategy. J Atr Fibrillation. 2008;1(2):13.4.
Yokokawa M, Olgun H, Sundaram B, Chugh A, Latchamsetty R, Good E, et al. Impact of preprocedural imaging on outcomes of catheter ablation in patients with atrial fibrillation. J Interv Card Electrophysiol. 2012;34(3):255–62.
Chyou JY, Biviano A, Magno P, Garan H, Einstein AJ. Applications of computed tomography and magnetic resonance imaging in percutaneous ablation therapy for atrial fibrillation. J Interv Card Electrophysiol. 2009;26:47–57.
Niinuma H, George RT, Arbab-Zadeh A, Lima JA, Henrikson CA. Imaging of pulmonary veins during catheter ablation for atrial fibrillation: the role of multi-slice computed tomography. Europace. 2008;10(Suppl. 3):iii14–21.7.
Rordorf R, Sanzo A, Gionti V. Contact force technology integrated with 3Dm navigation system for atrial fibrillation ablation: improving results? Expert Rev Med Devices. 2017;14(6):461–7.
Nedios S, Sommer P, Bollmann A, Hindricks G. Advanced Mapping Systems To Guide Atrial Fibrillation Ablation: Electrical Information That Matters. J Atr Fibrillation. 2016;8(6):1337.
The Measurement, Reporting, and Management of Radiation Dose in CT Report of AAPM Task Group 23: CT Dosimetry Diagnostic Imaging Council CT Committee. AAPM REPORT NO. 96. 2008.
Heidbuchel H, Wittkampf FHM, Vano E, Ernst S, Schilling R, Picano E, et al. Practical ways to reduce radiation dose for patients and staff during device implantations and electrophysiological procedures. Europace. 2014;16:946–64.11.
Haissaguerre M, Jais P, Shah DC, Takahashi A, Hocini M, Quiniou G, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339:659–66.
Nademanee K, McKenzie J, Kosar E, Schwab M, Sunsaneewitayakul B, Vasavakul T, et al. A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate. J Am Coll Cardiol. 2004;43:2044–53.
Nademanee K, Schwab MC, Kosar EM, Karwecki M, Moran MD, Visessook N, et al. Clinical outcomes of catheter substrate ablation for high-risk patients with atrial fibrillation. J Am Coll Cardiol. 2008;51:843–9.
Chyou JY, Biviano A, Magno P, Garan H, Einstein AJ. Applications of computed tomography and magnetic resonance imaging in percutaneous ablation therapy for atrial fibrillation. J Interv Card Electrophysiol. 2009;26:47–57.
Niinuma H, George RT, Arbab-Zadeh A, Lima JA, Henrikson CA. Imaging of pulmonary veins during catheter ablation for atrial fibrillation: the role of multi-slice computed tomography. Europace. 2008;10(Suppl. 3):iii14–21.
D’Silva A, Wright M. Advances in imaging for atrial fibrillation ablation. Radiol Res Practice. 2011;2011:714864.
Kistler PM, Rajappan K, Harris S, Earley MJ, Richmond L, Sporton SC, et al. The impact of image integration on catheter ablation of atrial fibrillation using electroanatomic mapping: a prospective randomized study. Eur Heart J. 2008;29:3029–36.
Kistler PM, Rajappan K, Jahngir M, Earley MJ, Harris S, Abrams D, et al. The impact of CT image integration into an electroanatomic mapping system on clinical outcomes of catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 2006;17:1093–101.
Sra J, Narayan G, Krum D, Malloy A, Cooley R, Bhatia A, et al. Computed tomography-fluoroscopy image integration-guided catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 2007;18:409–14.
Khaykin Y, Oosthuizen R, Zarnett L, Wulffhart ZA, Whaley B, Hill C, et al. CARTO-guided vs. NavX-guided pulmonary vein antrum isolation and pulmonary vein antrum isolation performed without 3-D mapping: effect of the 3-D mapping system on procedure duration and fluoroscopy time. J Interv Card Electrophysiol. 2011;30:233–40.
Estner HL, Deisenhofer I, Luik A, Ndrepepa G, von Bary C, Zrenner B, et al. Electrical isolation of pulmonary veins in patients with atrial fibrillation: reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (NavX). Europace. 2006;8:583–7.
Rotter M, Takahashi Y, Sanders P, Haissaguerre M, Jais P, Hsu LF, et al. Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system. Eur Heart J. 2005;26:1415–21.
Martinek M, Nesser HJ, Aichinger J, Boehm G, Purerfellner H. Impact of integration of multislice computed tomography imaging into threedimensional electroanatomic mapping on clinical outcomes, safety, and efficacy using radiofrequency ablation for atrial fibrillation. PACE. 2007;30:1215–23.
Kistler PM, Rajappan K, Jahngir M, Earley MJ, Harris S, Abrams D, et al. The impact of CT image integration into an electroanatomic mapping system on clinical outcomes of catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 2006;17:1093–101.
Kimura M, Sasaki S, Owada S, Horiuchi D, Sasaki K, Itoh T, et al. Comparison of lesion formation between contact force-guided and non-guided circumferential pulmonary vein isolation: a prospective, randomized study. Heart Rhythm. 2014;11:984–91.
Stabile G, Solimene F, Calo L, et al. Catheter-tissue contact force for pulmonary veins isolation: a pilot multicentre study on effect on procedure and fluoroscopy time. Europace. 2014;16:335–40.
Reddy VY, Shah D, Kautzner J, et al. The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm. 2012;9:1789–95.
Yokoyama K, Nakagawa H, Shah DC, Lambert H, Leo G, Aeby N, et al. Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus. Circ Arrhythm Electrophysiol. 2008;1:354–62.
Marijon E, Fazaa S, Narayanan K, Guy-Moyat B, Bouzeman A, Providencia R, et al. Real-time contact force sensing for pulmonary vein isolation in the setting of paroxysmal atrial fibrillation: procedural and 1-year results. J Cardiovasc Electrophysiol. 2014;25:130–7.
Zucchelli G, Sirico G, Rebellato L, Marini M, Stabile G, Del Greco M, et al. Contiguity Between Ablation Lesions and Strict Catheter Stability Settings Assessed by VISITAG(TM) Module Improve Clinical Outcomes of Paroxysmal Atrial Fibrillation Ablation- Results From the VISITALY Study. Circ J. 2018;82(4):974–82.
Yokokawa M, Olgun H, Sundaram B, Chugh A, Latchamsetty R, Good E, et al. Impact of preprocedural imaging on outcomes of catheter ablation in patients with atrial fibrillation. J Interv Card Electrophysiol. 2012;34(3):255–62.
Wagner M, Butler C, Rief M, Beling M, Durmus T, Huppertz A, et al. Comparison of non-gated vs. electrocardiogram-gated 64-detector-row computed tomography for integrated electroanatomic mapping in patients undergoing pulmonary vein isolation. Europace. 2010;12(8):1090–7.
Thai WE, Wai B, Truong QA. Preprocedural imaging for patients with atrial fibrillation and heart failure. Curr Cardiol Rep. 2012;14(5):584–92. https://doi.org/10.1007/s11886-012-0293-7.
Niinuma H, George RT, Arbab-Zadeh A, Lima JA, Henrikson CA. Imaging of pulmonary veins during catheter ablation for atrial fibrillation: the role of multi-slice computed tomography. Europace. 2008;10(Suppl 3):iii14–21.
Vorre MM, Abdulla J. Diagnostic accuracy and radiation dose of CT coronary angiography in atrial fibrillation: systematic review and meta-analysis. Radiology. 2013;267(2):376–86.
Gerber TC, Carr JJ, Arai AE, Dixon RL, Ferrari VA, Gomes AS, et al. Ionizing radiation in cardiac imaging: a science advisory from theAmerican Heart Association Committee on Cardiac Imaging of the Council on Clinical Cardiology and Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention. Circulation. 2009;119:1056–65.
Linet MS, Kim KP, Miller DL, Kleinerman RA, Simon SL, Berrington de Gonzalez A. Historical review of occupational exposures and cancer risks in medical radiation workers. Radiat Res. 2010;174:793–808.
Ang R, Hunter RJ, Baker V, et al. Pulmonary vein measurements on pre-procedural CT/MR im- aging can predict difficult pulmonary vein isolation and phrenic nerve injury during cryoballoon abla- tion for paroxysmal atrial fibrillation. Int J Cardiol. 2015;195:253–8.
Rathi VK, Reddy ST, Anreddy S, et al. Contrast- enhanced CMR is equally effective as TEE in the evaluation of left atrial appendage thrombus in patients with atrial fibrillation undergoing pul- monary vein isolation procedure. Heart Rhythm. 2013;10:1021–7.
Siebermair J, Kholmovski EG, Marrouche N. Assessment of Left Atrial Fibrosis by Late Gadolinium Enhancement Magnetic Resonance Imaging: Methodology and Clinical Implications. JACC Clin Electrophysiol. 2017;3(8):791–802.
Casella M, Perna F, Pontone G, Dello Russo A, Andreini D, Pelargonio G, et al. Prevalence and clinical significance of collateral findings detected by chest computed tomography in patients undergoing atrial fibrillation ablation. Europace. 2012;14(2):209–16.
Trattner S, Halliburton S, Thompson CM, Xu Y, Chelliah A, Jambawalikar SR, et al. Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography. JACC Cardiovasc Imaging. 2018;11(1):64–74.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Di Cori, A., Zucchelli, G., Faggioni, L. et al. Role of pre-procedural CT imaging on catheter ablation in patients with atrial fibrillation: procedural outcomes and radiological exposure. J Interv Card Electrophysiol 60, 477–484 (2021). https://doi.org/10.1007/s10840-020-00764-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10840-020-00764-4