1 Introduction

Electromagnetic waves at millimeter (30–300 GHz, MMW) and submillimeter (300 GHz–3 THz) waveband frequencies are expected to be increasingly used in advanced technologies such as high-speed and broadband communications, wireless power transmission, remote sensing, and more. However, at present, there is sparse in vivo research data regarding the impact of these energy forms on living tissues.

It was reported several decades ago that energy in the frequency range 10–300 GHz was absorbed by the skin surface and the surface tissue of eyeballs [1]. Studies have examined the effects to eyes of MMW exposure [2,3,4,5,6,7,8], but because their exposure methodology (especially, shape of antenna (radiation pattern of antenna) for MMW delivery) and experimental animals differed, the results of these studies cannot be directly compared. We have previously reported data on the threshold of eye injury in Dutch rabbits exposed to 40, 75, and 95 GHz MMW using uniform experimental procedures [7].

One aim of the present study was to compare the threshold of eye injury for 162 GHz MMW exposure in the same rabbit breed using the same experimental method as in our previous reports. A high-power MMW exposure device is essential to create a highly reproducible ocular injury model. However, in general, it is technologically difficult to realize high-power MMW exposure by solid-state semiconductors, which we have used in our previous study, approximately from 100 GHz to 10 THz. This is a well-known problem termed “THz gap” [9]. Therefore, we focused on the gyrotron as a candidate high-power MMW wave source above 100 GHz.

The gyrotron is an oscillating tube to which the cyclotron resonance maser principle is applied utilizing the mass change of electrons due to the relativistic effect. Applications of the gyrotron are being developed including electronic heating in the plasma science and fusion fields, the output of which reaches 1 MW (Mega Watt) at a frequency of about 100 GHz [10]. As the University of Fukui was undertaking research using a gyrotron and was looking for joint researchers, we considered the possibility of using a gyrotron for the wave source in the present study. Thus, a second aim was to use a gyrotron to investigate the threshold of ocular damage associated with exposure to 162 GHz MMW. A third aim was to clarify the clinical course of ocular damage and its healing process after 162 GHz MMW exposure.

As far as the authors know, there are no reports of millimeter-wave eye injuries above 100 GHz other than one by Rosenthal et al. who investigated the effects of exposure to 107 GHz [2]. This is the first report of eye injuries caused by exposure to 162 GHz MMW.

2 Materials and Methods

2.1 Exposure System

Figure 1 shows a block diagram of the exposure system used in this study. A 162-GHz MMW energy source in continuous wave mode was generated by the gyrotron FU CW GV constructed in University of Fukui [11]. A lens antenna (diameter 100 mm) with a 200-mm focal point and 6.5-mm FWHM (full width at half its maximum intensity) beam width was used to deliver MMW to rabbit cornea. The power distribution was verified using a waveguide probe (AOEWGP-02/3.0, Elmika, Vilnius, Lithuania) with gain obtained by the three-antenna method [12] and a power meter (Erikson PM4, Virginia Diodes, Inc., USA), and total power incident to the lens antenna was monitored using a power meter (Erikson PM5, Virginia Diodes, Inc., USA).

Fig. 1
figure 1

A block diagram of the developed 162 GHz exposure system

Figure 2 shows the method of measuring spatial power distribution. The measurement plane was 200 mm from the lens antenna, which is the focal point of the antenna, and perpendicular to the z-axis. The open-ended waveguide probe was swept across this plane from (− xmax, − ymax) to (xmax, ymax). The intervals of measurement points, i.e., ∆x and ∆y, were 0.5 mm. The results of measurement of power distribution at the focal point are shown in Fig. 3. In this figure, the vertical axis is normalized by the maximum value at the axis of the lens antenna. FWHM was estimated by this result as 6.5 mm.

Fig. 2
figure 2

Method of measuring spatial power distribution

Fig. 3
figure 3

Measurement result of power distribution at the focal point

In this study, the spatially averaged power per area with a diameter of 13 mm, which is the average size of the corneal region in Dutch-belted rabbits, was calculated from the monitored power and measurement results of the power distribution at the focal plane. The relationship between input power to the antenna and averaged power density at the focal plane was determined by measurement of lens antenna properties including power loss by the antenna and the coupler.

2.2 Experimental Animals

The animals were managed in accordance with practices and experimental protocols reviewed and approved by the Animal Research Committee, University of Fukui. All animal experiments were conducted in accordance with the animal experimentation guidelines of Kanazawa Medical University (Kahoku, Japan), University of Fukui (Fukui, Japan), and the ARVO Statement for the Use of Animals in Ophthalmic and Vision Research (ARVO, 2016) [13].

Forty-six male Dutch-belted pigmented rabbits (age: 10–13 weeks, mean ± SD weight: 1.85 ± 0.03 kg) were purchased from Sankyo Labo Service Co., Inc. (Toyama, Japan). They were housed individually in stainless steel rabbit housing cages kept in a cargo van as short-term animal housing. Before starting this experiment, we confirmed that the cargo van animal housing did not differ from a conventional animal facility, at least for short-term housing [14].

Each rabbit was injected subcutaneously or intramuscularly (IM) with a solution containing 0.25–0.50 mg/kg of medetomidine hydrochloride (Domitor, Nippon Zenyaku Kogyo Co., Ltd., Fukushima, Japan) and 0.025–0.050 mg/kg buprenorphine hydrochloride (Buprenorphine Inj. 0.2 mg “NISSIN”, Nissin Pharmaceutical Co., Ltd., Yamagata, Japan) to induce general anesthesia or to provide sedation and immobilized in an acrylic rabbit restrainer which was specially constructed for studies of exposure to MMW [5]. All rabbit eyes were pre-examined using a slit-lamp microscope (SL-130, Zeiss, Tokyo, Japan) to ensure absence of abnormalities, and each eye was photographed to confirm the pre-experimental ocular condition. Immediately before MMW exposure, 2% lidocaine hydrochloride topical anesthetic (Xylocaine 2%, AstraZeneca, Osaka, Japan) was instilled to each eye. The upper and lower eyelids of both eyes (exposed and control) were held open with tape. As necessary, to prevent corneal epithelial damage from corneal desiccation, and to ensure equivalent ocular surface conditions among rabbits, saline drops were instilled to the experimental eyes before exposure and the contralateral eyes as controls. All rabbits were administered topical ofloxacin eye drops and ointment (Tarivid, Santen Pharmaceutical Co., Ltd., Osaka, Japan) to prevent secondary infection after experimental treatment was competed each day. Temperature and humidity during exposure were maintained at 24 ± 2 °C and 60 ± 10%, respectively, using an air conditioner and dehumidifier. Anesthesia was reversed with 0.8–1.5 mg/kg IM atipamezole hydrochloride (Antisedan, Nippon Zenyaku Kogyo Co., Ltd., Fukushima, Japan) to aid rabbit recovery.

2.3 MMW Exposure

Prior to the animal experiment, the most uniformly irradiated site was identified by investigation of the detailed beam profile of the antenna used in this experiment. The center of the corneal surface of the right eye was positioned 200 mm from the antenna aperture and on the line of maximum radiation of the antenna. According to Kojima’s methodology [5, 6], the exposure point was set using red and green laser pointers on a target, and 46 right eyes of Dutch rabbits were continuously exposed to 162 GHz MMW at 60–600 mW/cm2 for 6 min. The corresponding 46 left eyes were unexposed and regarded as control eyes.

2.4 Corneal Surface Temperature

Corneal surface temperature was recorded in exposed eyes at 5 s prior to exposure and 5 s before the end of exposure using a thermography camera (FLIR T620, FLIR Systems, Inc., Oregon, USA).

2.5 Examination of Ocular Injury

The anterior segment was evaluated before exposure, and at 10 min, 1, 2, 3, 6, and 9 days after exposure. Corneal epithelial damage was observed by slit-lamp microscopy using a modified Rosenthal’s method [2] where fluorescein staining revealed damaged corneal epithelial cells [7]. Corneal cross-sectional thickness was measured and recorded by optical coherence tomography (CIRRIS HD-OCT plus model 5000, Zeiss, Tokyo, Japan), and corneal opacity was assessed by slit-lamp microscopy. Measurements of corneal thickness were taken at three points, 1.5 mm above (upper) and 1.5 mm below (lower) the pupillary central region, and at the center of the pupil (middle).

2.6 Categorization of Corneal Epithelial Injury

Corneal epithelial damage was defined as presence of fluorescein staining, indicating an area of epithelial injury in the central pupillary zone of the exposed eye (right eye), with no similar injury observed in its corresponding unexposed eye (left eye). Other types of corneal epithelial damage, such as desiccation of the cornea (i.e., dry eye) and mechanical damage, were excluded and in any case did not occur.

2.7 Data Analysis

The probability of corneal damage at 1 day after exposure to 162 GHz MMW at different power densities was evaluated by maximum likelihood estimation (MLE) using probit analysis [15]. The morphological changes in the cornea assessed by slit-lamp microscopy, including corneal opacity, and fluorescein staining revealing corneal epithelial damage, and anterior segment optical coherence tomography (ASOCT) to measure corneal edema at 1 day after exposure, were used for the probit analyses. The dose-response relationship between corneal injury and power density was evaluated by fitting with a cumulative lognormal distribution function for probit analysis using R Ver 3.5.2 software [16]. The MMW power density indicating the probability of ocular damage was defined as damage dose (DD) and was derived from the best-fit probit function with p ≤ 0.01.

3 Results and Discussion

3.1 Exposure to 162 GHz at 600 mW/cm2 for 6 Min

Since this was the first investigation of ocular injury using a gyrotron, examination of characteristics of MMW induced eye damage required a sufficiently high exposure dose. Two right eyes were exposed to 162 GHz at 600 mW/cm2 for 6 min. Our ethical protocol for discontinuation was a cornea becoming turbid during exposure or the animal showing a strong rejection response.

Experiments were performed using two rabbits in which responses requiring discontinuation did not occur during 6-min exposure. At 10 min after exposure, miosis was observed in both animals indicating induced ocular inflammation. At 1 day after exposure, in both rabbits, the anterior segment including the cornea was completely opaque obscuring observation of the pupil shape. In both rabbits, the unexposed control eyes (left eye) remained normal throughout the experimental period.

The effect on the rabbit eye by exposure to 162 GHz at 600 mW/cm2 for 6 min was similar to damage caused by high dose exposure to 40, 75, and 95 GHz reported by Kojima et al [7]. Ocular damage due to high-intensity MMW exposure is miosis and corneal epithelial damage (fluorescein staining findings) observed immediately (10 min) after exposure [7]. Corneal opacification occurs to the extent that the pupil cannot be observed at 1 day after exposure.

Experiments including exposure to 162 GHz at doses above 600 mW/cm2 or at this level for more than 6 min were deemed unethical and not conducted.

3.2 162 GHz MMW Ocular Damage Model

Figure 4 shows a representative example of eye injury caused by 162 GHz at 480 mW/cm2 for 6 min exposure.

Fig. 4
figure 4

Representative examples of eyes with corneal damage and their clinical courses following their exposure to 162 GHz MMW at 480 mW/cm2 for 6 min. The numbers indicate corneal thickness in millimeters

Thermographic measurement of corneal surface temperature showed 31.5 °C before exposure and 48.5 °C (ΔT = 17.0 °C) 5 s before the end of exposure.

Slit-lamp examination at 10 min after exposure (162 GHz 480 mW/cm2 for 6 min) revealed corneal epithelial damage (fluorescein staining findings) in 2 of 10 eyes. And in all 10, including those without corneal epithelial damage, ASOCT revealed cornea thicknesses was reduced following exposure. Before exposure, the corneal thicknesses (upper, middle, lower) measured by ASOCT showed normal values of 0.36, 0.36, and 0.37 mm, respectively. In the observation at 10 min after exposure, those were thinned to 0.33, 0.32, and 0.30 mm, respectively. Unexposed control eyes (left eye) remained normal throughout the experimental period.

Kojima et al. reported the initial steps of corneal injury at 10 min after exposure to MMW (40, 75, 95 GHz) are “thinning of cornea (corneal desiccation)” and “partial dropout of corneal epithelial cells”. In the present study, thinning of the cornea was observed in all 10 cases, but fluorescein staining was observed in only 2 of 10 cases. In the fluorescein staining test at 1 day after exposure, all 10 eyes were positive and showed corneal opacity, so it is considered that the exposure dose was sufficient to cause ocular damage. The cause of the discrepancy between the findings at 10 min and at 1 day after exposure is unknown at present, but examination at 10 min after exposure can be said to be unsuitable for determining ocular damage due to 162 GHz MMW exposure.

In the present study, corneal opacity in exposed eyes at 1 day after exposure was observed in the central pupillary zone, and fluorescein staining was present where corneal opacity was observed. In the measurement of corneal thickness by ASOCT at 1 day after exposure, edema was observed in the upper (0.44 mm) and central cornea (0.48 mm).

Slit-lamp microscopy at 2 days after exposure revealed the degree of corneal turbidity was reduced compared to that at 1 day after exposure. In addition, the area of fluorescein staining at 2 days after exposure was smaller than that at 1 day after exposure. These findings suggest that ocular damage caused by exposure to 162 GHz at 480 mW/cm2 for 6 min peaked around 1 day after exposure, and healing gradually started. On the contrary, in the examination of corneal thickness at 2 days after exposure, edema was observed to have increased.

Three days after exposure, corneal opacity recovered and fluorescein staining disappeared. However, corneal edema was somewhat improved but still present. Corneal edema was observed at 6 days after exposure, but returned to normal corneal thickness by 9 days after exposure. Unexposed control eyes (left eye) remained normal throughout the experimental period.

Ocular damage by exposure to 162 GHz at 480 mW/cm2 for 6 min was judged to be appropriate as a rabbit model eye for MMW exposure, as the degree of damage was ethically acceptable. A total of 10 rabbits were similarly exposed over different days to investigate the reproducibility of this MMW exposure animal model. The average corneal surface temperature was 48.5 ± 1.2 °C (CV = 2.5%, max temperature: 51.2 °C, Min temperature 46.7 °C).

Ocular damage caused by exposure to 162 GHz at 480 mW/cm2 for 6 min has the following 3 characteristics: (1) Not severe enough to cause the rabbit cornea to become opaque during exposure. (2) Ocular damage after exposure is reversible turbidity that reaches its peak around 1 day after exposure and gradually recovers. (3) Ocular damage caused by this exposure, including corneal opacity, corneal epithelial injury (defined by fluorescein staining), and corneal edema, show good simultaneous and day-to-day reproducibility (10 rabbits similarly exposed showed similar ocular damage with little variation). Accordingly, we determined that 162 GHz at 480 mW/cm2 6-min exposure condition could provide a model for ocular damage of 162 GHz MMW.

3.3 Threshold of 162 GHz MMW Ocular Damage Model

Table 1 shows the relationship between different power density values of 162 GHz (incident power density) and the proportion of eyes damaged (damaged/exposed). The corneal surface temperature measured during MMW exposure (5 s before the end of exposure) is also shown. Under the exposure condition of 162 GHz at 480 mW/cm2 for 6 min, the corneal surface temperature was 48.5 ± 1.2 °C, and corneal epithelial injury (positive fluorescein staining), corneal opacification (slit-lamp observation), and corneal edema (ASOCT examination) were observed in all of 10 exposed eyes.

Table 1 Summary of the results at 1 day after exposure of rabbit eyes to 162 GHz MMW

Under the condition of 300 mW/cm2 exposure for 6 min, the corneal surface temperature was 44.4 ± 0.8 °C, corneal epithelial damage and corneal edema were present in 4 of 5 exposed eyes, and corneal opacity in 2 of 5.

A previous study compared the effects of exposure to 40, 75, and 95 GHz MMW at 300 mW/cm2 for 6 min using rabbit corneal surface temperature as an index and reported that the corneal surface temperature at 5 s before the end of exposure was in the order of 75 (50.7 ± 1.9 °C) > 95 (46.5 ± 1.3 °C) > 40 GHz (41.3 ± 1.3 °C) [7]. Since the protocols of the present experiment were the same as those of the previous experiment, except for the MMW source, results of the present experiment may reliably be compared with those of the previous. The corneal surface temperature at 5 s before the end of exposure to 162 GHz at 300 mW/cm2 for 6 min was 44.4 ± 0.8 °C. Differences in corneal surface temperature induced by exposure to 300 mW/cm2 at different MMW frequencies seem to be due to penetration depth [17] depending on MMW frequency.

When exposed to 162 GHz at 120 mW/cm2 for 6 min, the corneal surface temperature at 5 s before the end of exposure was 37.6 ± 0.7 °C, which is within the range of rabbit body temperature, 37.3–39.8 °C [18]. All 6 rabbits exposed to 162 GHz at 120 mW/cm2 for 6 min showed no ocular damage.

Under the condition of 162 GHz at 60 mW/cm2 for 6 min, the cornea temperature at 5 s before the end of exposure was 34.3 ± 0.8 °C, which is below the rabbit average body temperature.

Based on the above, it was estimated that the onset threshold of ocular damage caused by exposure to 162 GHz MMW for 6 min was in the range of 120–240 mW/cm2.

We used the ocular damage model (162 GHz at 480 mW/cm2 for 6 min) as a positive control, and in the process of reducing the power density of exposure, we defined the time point when the onset of ocular damage disappeared as a threshold, and performed ocular damage threshold research.

The relationship between ocular damage and 162 GHz MMW at various power densities was evaluated by determining the probability of corneal damage at 1 day after exposure by MLE using probit analysis (Fig. 5). The black line plotted in the graph denotes the probability of ocular damage by power density (dose).

Fig. 5
figure 5

Results of MLE with probit analysis for exposure to 162 GHz MMW. The markers in the graph denote the dependence of the proportion of damaged eyes relative to the number of eyes exposed to the indicated power density (dose). The number of rabbit eyes at each power density correspond to the size of the diamond-shaped markers. The blue and red lines indicate the lower and upper limits of 95% confidence intervals, respectively

Figure 6 shows the results of probit analysis of 40, 75, and 95 GHz summed with 162 GHz in the present study. The DD 10% (DD10), DD 50% (DD50), and DD 90% (DD90) was determined by MLE, following exposure to 40, 75, 95 (data from [7]), and 162 GHz MMW. The 50% probability of ocular damage (DD50) was in the order 162 (252 mW/cm2) > 40 (206 mW/cm2) > 95 (146 mW/cm2) > 75 GHz (143 mW/cm2).

Fig. 6
figure 6

Estimation of power density threshold level for 6 min exposure with probit analysis from 40 to 162 GHz. DD 10% (DD10), DD 50% (DD50), and DD 90% (DD90) estimated from results of MLE for exposure to 40, 75, 95 [7], and 162 GHz MMW. Error bars indicate 95% confidence intervals for each marker

4 Conclusion

We developed a 162-GHz MMW ocular damage rabbit model using a gyrotron as the wave source and clarified the degree of ocular damage caused by 162 GHz exposure for 6 min, the clinical course of ocular damage, and the damage healing process. Although there were slight differences in the degree of ocular damage found in this study compared to our previous studies, there was no fundamental difference from previous reports of MMW induced ocular damage [5, 7]. The ocular damage dose (DD) power densities at 162 GHz MMW with probabilities of 10, 50, and 90% obtained by probit analysis were 173, 252, and 368 mW/cm2, respectively.