Skip to main content
Log in

A cooperation of catheters and guidewires-based novel remote-controlled vascular interventional robot

  • Published:
Biomedical Microdevices Aims and scope Submit manuscript

Abstract

Remote-controlled vascular interventional robots (RVIRs) are being developed to increase the overall accuracy of surgical operations and reduce the occupational risks of intervening physicians, such as radiation exposure and chronic neck/back pain. Several RVIRs have been used to operate catheters or guidewires accurately. However, a lack of cooperation between the catheters and guidewires results in the surgeon being unable to complete complex surgery by propelling the catheter/guidewire to the target position. Furthermore, it is a significant challenge to operate the catheter/guidewire accurately and detect their proximal force without damaging their surfaces. In this study, we introduce a novel method that allows catheters and guidewires to be operated simultaneously in complex surgery. Our method accurately captures force measurements and enables precisely controlled catheter and guidewire operation. A prototype is validated through various experiments. The results demonstrate the feasibility of the proposed RVIR to operate a catheter and guidewire accurately, detect the resistance forces, and complete complex surgical operations in a cooperative manner.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
Fig. 20
Fig. 21
Fig. 22

Similar content being viewed by others

References

  • F. Arai, R. Fujimura, T. Fukuda, M. Negoro, New catheter driving method using linear stepping mechanism for intravascular neurosurgery. IEEE Int Conf Robot Autom., 2944–2949 (2002)

  • X. Bao, S. Guo, N. Xiao, Y. Wang, M. Qin, Y. Zhao, C. Xu, W. Pen, Design and evaluation of a novel guidewire navigation robot. IEEE Int Conf Mech Autom., 431–436 (2016)

  • R. Beyar, L. Gruberg, D. Deleanu, A. Roguin, Y. Almagor, S. Cohen, G. Kumar, T. Wenderow, Remote-control percutaneous coronary interventions: Concept, validation, and first-in-humans pilot clinical trial. J. Am. Coll. Cardiol. 47(2), 296–300 (2006)

    Article  Google Scholar 

  • G. Bian, X. Xie, Z. Feng, Z. Hou, P. Wei, L. Cheng, M. Tan, An enhanced dual-finger robotic Hand for Catheter manipulating in vascular intervention: A preliminary study. IEEE Int Conf Inform Autom, 356–361 (2014)

  • L. Cercenelli, E. Marcelli, G. Plicchi, Initial experience with a Telerobotic system to remotely navigate and automatically reposition standard steerable EP catheters. ASAIO J. 53(5), 523–529 (2007)

    Article  Google Scholar 

  • D. Cheng, Handbook of Mechanical Design, 7–8 (Chemical Industry Press, Beijing, China, 2008)

    Google Scholar 

  • M. Faddis, W. Blume, J. Finney, A. Hall, J. Rauch, J. Sell, K. Bae, M. Talcott, B. Lindsay, Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation. Circulation 106(23), 2980–2985 (2002)

    Article  Google Scholar 

  • Z. Feng, G. Bian, X. Xie, Z. Hou, J. Hao, Design and evaluation of a bio-inspired robotic hand for percutaneous coronary intervention. IEEE Int Conf Robot Autom., 5338–5343 (2015)

  • Y. Fu, H. Liu, S. Wang, W. Deng, X. Li, Z. Liang, Skeleton-based active catheter navigation. Int J Med Robot Comput Assisted Surg. 5(2), 125–135 (2009)

    Article  Google Scholar 

  • Y. Fu, A. Gao, H. Liu, K. Li, Z. Liang, Development of a novel robotic catheter system for endovascular minimally invasive surgery. IEEE/ICME Int Conf Complex Med Eng., 400–405 (2011)

  • J. Guo, S. Guo, Design and characteristics evaluation of a novel VR-based robot-assisted catheterization training system with force feedback for vascular interventional surgery. Microsyst. Technol. 23(8), 1–10 (2016)

    Google Scholar 

  • S. Guo, T. Fukuda, K. Kosuge, F. Arai, K. Oguro, M. Negoro, Micro catheter system with active guide wire. IEEE Int Conf Robot Autom., 79–84 (1995)

  • S. Guo, H. Yamaji, Y. Kita, K. Izuishi, T. Tamiya, A novel active catheter system for ileus treatment. IEEE Int Conf Autom Logistics, 67–72 (2008)

  • J. Guo, S. Guo, Y. Yu, Design and characteristics evaluation of a novel teleoperated robotic catheterization system with force feedback for vascular interventional surgery. Biomed. Microdevices 18(5), 76–92 (2016)

    Article  Google Scholar 

  • J. Jayender, R. Patel, A.S. Nikumb, Robot-assisted catheter insertion using hybrid impedance control. IEEE Int Conf Robot Autom, 607–612 (2006)

  • J. Jayender, M. Azizian, R. Patel, Autonomous image-guided robot-assisted active catheter insertion. IEEE Trans. Robot. 24(4), 858–871 (2008)

    Article  Google Scholar 

  • L. Jones, in Human and Machine Haptics. By M. Cutkosky, R. Howe, K. Salisbury, and M. Srinivasan, Eds., MIT Press. Cambridge (2000)

  • C. Jr, Robotic-assisted percutaneous coronary intervention filling an unmet need. J. Cardiovasc. Transl. Res. 5(1), 62–66 (2012)

    Article  Google Scholar 

  • P. Kanagaratnam, M. Koawing, D. Wallace, A. Goldenberg, N. Peters, D. Davies, Experience of robotic catheter ablation in humans using a novel remotely steerable catheter sheath. J. Interv. Card. Electrophysiol. 21(1), 19–26 (2008)

    Article  Google Scholar 

  • SB. Kesner, RD. Howe, Design and control of motion compensation cardiac catheters. IEEE Int Conf Robot Autom., 1059–1065 (2010)

  • SB. Kesner, RD. Howe, Force control of flexible catheter robots for beating heart surgery. IEEE Int Conf Robot Autom., 1589–1594 (2011)

  • E. Khan, W. Frumkin, G. Ng, S. Neelagaru, F. Abi-Samra, J. Lee, M. Giudici, D. Gohn, R. Winkle, J. Sussman, B. Knight, A. Berman, H. Calkins, First experience with a novel robotic remote catheter system: Amigo™ mapping trial. J. Interv. Card. Electrophysiol. 37(2), 121–129 (2013)

    Article  Google Scholar 

  • L. Klein, D. Miller, S. Balter, W. Laskey, D. Haines, A. Norbash, M. Mauro, J. Goldstein, Occupational health hazards in the interventional laboratory: Time for a safer environment. Catheter Cardiovasc Interv. 73(3), 432–438 (2009)

    Article  Google Scholar 

  • E. Marcelli, L. Cercenelli, G. Plicchi, A novel telerobotic system to remotely navigate standard electrophysiology catheters. Comput. Cardiol. 35, 137–140 (2008)

    Google Scholar 

  • C. Meng, J. Zhang, D. Liu, B. Liu, F. Zhou, A remote-controlled vascular interventional robot: System structure and image guidance. Int J Med Robot Comput Assisted Surg. 9(2), 230–239 (2013)

    Article  Google Scholar 

  • J. Park, J. Choi, H. Pak, S. Song, J. Lee, Y. Park, S. Shin, K. Sun, Development of a force-reflecting robotic platform for cardiac catheter navigation. Artif. Organs 34(11), 1034–1039 (2010)

    Article  Google Scholar 

  • C. Riga, C. Bicknell, M. Hamady, N. Cheshire, Evaluation of robotic endovascular catheters for arch vessel cannulation. J. Vasc. Surg. 54(3), 799–809 (2011)

    Article  Google Scholar 

  • C. Riga, C. Bicknell, A. Rolls, N. Cheshire, M. Hamady, Robot-assisted fenestrated endovascular aneurysm repair (FEVAR) using the Magellan system. J Vasc Interv Radiol. 24(2), 191–196 (2013)

    Article  Google Scholar 

  • W. Saliba, J. Cummings, S. Oh, Y. Zhang, T. Mazgalev, R. Schweikert, J. Burkhardt, A. Natale, Novel robotic catheter remote control system: Feasibility and safety of transseptal puncture and endocardial catheter navigation. J. Cardiovasc. Electrophysiol. 17(10), 1102–1105 (2006)

    Article  Google Scholar 

  • M. Schiemann, R. Killmann, M. Kleen, N. SchAbolmaali, J. Finney, T. Vogl, Vascular guide wire navigation with a magnetic guidance system: Experimental results in a phantom. Radiology 232(2), 475–481 (2004)

    Article  Google Scholar 

  • J. Shen, S. Li, D. Chen, Y. Yan, Design and experiment of guide wire tele-manipulation system based on laser mouse sensor. Chinese J Med Inst 36(1), 32–35 (2012)

    Google Scholar 

  • G. Srimathveeravalli, T. Kesavadas, X. Li, Design and fabrication of a robotic mechanism for remote steering and positioning of interventional devices. Int J Med Robot Comput Assisted Surg. 6(2), 160–170 (2010)

    Google Scholar 

  • M. Tanimoto, F. Arai, T. Fukuda, H. Iwata, K. Itoigawa, Y. Gotoh, M. Hashimoto, M. Negoro, Micro force sensor for intravascular neurosurgery and in vivo experiment. IEEE Int Confer Robot Autom., 504–509 (1997)

  • M. Tanimoto, F. Arai, T. Fukuda, K. Itoigawa, M. Hashimoto, I. Takahashi, M. Negoro, Telesurgery system for intravascular neurosurgery. Int Confer Med Image Comput Comput Assisted Interv., 29–39 (2000)

  • M. Tavallaei, D. Gelman, M. Lavdas, A. Skanes, D. Jones, J. Bax, M. Drangova, Design, Development and evaluation of a compact telerobotic catheter navigation system. Int J Med Robot Comput Assisted Surg 12(3), 442–452 (2016)

    Article  Google Scholar 

  • R. Taylor, D. Stoiariovici, Medical robotics in computer-integrated surgery. IEEE Trans Rob Autom 19(5), 765–781 (2003)

    Article  Google Scholar 

  • C. Tercero, S. Ikeda, T. Uchiyama, T. Fukuda, F. Arai, Y. Okada, Y. Ono, R. Hattori, T. Yamamoto, M. Negoro, I. Takahashi, Autonomous catheter insertion system using magnetic motion capture sensor for endovascular surgery. Int J Med Robot Comput Assisted Surg 3(1), 52–58 (2010)

    Article  Google Scholar 

  • Y. Thakur, D.W. Holdsworth, M. Drangova, Characterization of catheter dynamics during percutaneous transluminal catheter procedures. IEEE Trans. Biomed. Eng. 56(8), 2140–2143 (2009a)

    Article  Google Scholar 

  • Y. Thakur, J. Bax, D. Holdsworth, M. Drangova, Design and performance evaluation of a remote catheter navigation system. IEEE Trans. Biomed. Eng. 56(7), 1901–1908 (2009b)

    Article  Google Scholar 

  • T. Wang, D. Zhang, D. Liu, Remote-controlled vascular interventional surgery robot. Int J Med Robot Comput Assisted Surg. 6(2), 194–201 (2010)

    Google Scholar 

  • Y. Wang, S. Guo, T. Tamiya, H. Hirata, H. Ishihara, X. Yin, A virtual-reality simulator and force sensation combined catheter operation training system and its preliminary evaluation. Int J Med Robot Comput Assisted Surg (2016). https://doi.org/10.1002/rcs.e1769

  • M. Whitby, C. Martin, A study of the distribution of dose across the hands of interventional radiologists and cardiologists. Br. J. Radiol. 78(927), 219–229 (2005)

    Article  Google Scholar 

  • N. Xiao, S. Guo, J. Guo, X. Xiao, Development of a kind of robotic catheter manipulation system. IEEE Int Confer Robot Biomi., 32–37 (2008)

  • N. Xiao, J. Guo, S. Guo, T. Tamiya, A robotic catheter system with real-time force feedback and monitor. Australas Phys Eng Sci Med. 35(3), 283–289 (2012)

    Article  Google Scholar 

  • N. Xiao, L. Shi, B. Gao, S. Guo, T. Tamiya, Clamping force evaluation for a robotic catheter navigation system. Neurosci Biomed Eng. 1(2), 141–145 (2013)

    Article  Google Scholar 

  • X. Yin, S. Guo, N. Xiao, T. Tamiya, Safety operation consciousness realization of a MR fluids-based novel haptic Interface for Teleoperated catheter minimally invasive neuro surgery. IEEE Trans Mechatronics. 21(2), 1043–1054 (2016)

    Article  Google Scholar 

  • N. Zakaria, T. Komeda, C. Low, K. Mahadhir, Development of foolproof catheter guide system based on mechatronic design. Prod. Eng. 7(1), 81–90 (2013)

    Article  Google Scholar 

  • P. Zhang, S. Yu, Y. Hu, X. Ma, J. Zhang, Design of a novel master-slave robotic system for minimally intravascular invasive surgery. IEEE Int Conf Mech Autom., 259–264 (2011)

Download references

Acknowledgements

This research is partly supported by National High-tech Research and Development Program (863 Program) of China (No.2015AA043202), and National Natural Science Foundation of China (61375094).

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Shuxiang Guo or Nan Xiao.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bao, X., Guo, S., Xiao, N. et al. A cooperation of catheters and guidewires-based novel remote-controlled vascular interventional robot. Biomed Microdevices 20, 20 (2018). https://doi.org/10.1007/s10544-018-0261-0

Download citation

  • Published:

  • DOI: https://doi.org/10.1007/s10544-018-0261-0

Keywords

Navigation